Cargando…

Retina-sparing suprachoroidal intraocular foreign body resulting in cyclodialysis cleft

PURPOSE: Suprachoroidal intraocular foreign bodies (IOFBs) are an exceedingly rare manifestation of ocular trauma. Here we present a unique case of a metallic wire tracking from the cornea through the suprachoroidal space, and remarkably sparing the retina and lens. The patient attained an excellent...

Descripción completa

Detalles Bibliográficos
Autores principales: Kane, Colin P., Johnson, Thomas V., Sachdeva, Mira M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9095656/
https://www.ncbi.nlm.nih.gov/pubmed/35572608
http://dx.doi.org/10.1016/j.ajoc.2022.101571
_version_ 1784705804489719808
author Kane, Colin P.
Johnson, Thomas V.
Sachdeva, Mira M.
author_facet Kane, Colin P.
Johnson, Thomas V.
Sachdeva, Mira M.
author_sort Kane, Colin P.
collection PubMed
description PURPOSE: Suprachoroidal intraocular foreign bodies (IOFBs) are an exceedingly rare manifestation of ocular trauma. Here we present a unique case of a metallic wire tracking from the cornea through the suprachoroidal space, and remarkably sparing the retina and lens. The patient attained an excellent visual outcome after management of resultant cyclodialysis cleft. OBSERVATIONS: A 34-year-old male experienced a penetrating IOFB while operating a rotary wire brush. He presented to the emergency department where posterior involvement of the IOFB was confirmed on CT scan. He underwent emergent pars plana vitrectomy, during which the IOFB was found to be located underneath intact retina and choroid on scleral depression. The wire was removed through the entry wound, which was self-sealing. At follow up, intraocular pressure was 3 mmHg with findings of hypotony. A cyclodialysis cleft was confirmed with ultrasound biomicroscopy. Cycloplegic and photocoagulation treatments were attempted, but ultimately direct cyclopexy was performed to successfully repair the cleft. One year after the initial incident, visual acuity is 20/25 and IOP is 17 mmHg. CONCLUSION AND IMPORTANCE: Cyclodialysis cleft is a rare sequela of penetrating ocular injury. Clinicians should consider the presence of a cyclodialysis cleft in the setting of postoperative hypotony and confirm either with gonioscopy or other anterior segment imaging methods. Despite failure of conservative therapies, our patient had an excellent visual outcome following surgical closure of the cleft.
format Online
Article
Text
id pubmed-9095656
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-90956562022-05-13 Retina-sparing suprachoroidal intraocular foreign body resulting in cyclodialysis cleft Kane, Colin P. Johnson, Thomas V. Sachdeva, Mira M. Am J Ophthalmol Case Rep Case Report PURPOSE: Suprachoroidal intraocular foreign bodies (IOFBs) are an exceedingly rare manifestation of ocular trauma. Here we present a unique case of a metallic wire tracking from the cornea through the suprachoroidal space, and remarkably sparing the retina and lens. The patient attained an excellent visual outcome after management of resultant cyclodialysis cleft. OBSERVATIONS: A 34-year-old male experienced a penetrating IOFB while operating a rotary wire brush. He presented to the emergency department where posterior involvement of the IOFB was confirmed on CT scan. He underwent emergent pars plana vitrectomy, during which the IOFB was found to be located underneath intact retina and choroid on scleral depression. The wire was removed through the entry wound, which was self-sealing. At follow up, intraocular pressure was 3 mmHg with findings of hypotony. A cyclodialysis cleft was confirmed with ultrasound biomicroscopy. Cycloplegic and photocoagulation treatments were attempted, but ultimately direct cyclopexy was performed to successfully repair the cleft. One year after the initial incident, visual acuity is 20/25 and IOP is 17 mmHg. CONCLUSION AND IMPORTANCE: Cyclodialysis cleft is a rare sequela of penetrating ocular injury. Clinicians should consider the presence of a cyclodialysis cleft in the setting of postoperative hypotony and confirm either with gonioscopy or other anterior segment imaging methods. Despite failure of conservative therapies, our patient had an excellent visual outcome following surgical closure of the cleft. Elsevier 2022-05-03 /pmc/articles/PMC9095656/ /pubmed/35572608 http://dx.doi.org/10.1016/j.ajoc.2022.101571 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Kane, Colin P.
Johnson, Thomas V.
Sachdeva, Mira M.
Retina-sparing suprachoroidal intraocular foreign body resulting in cyclodialysis cleft
title Retina-sparing suprachoroidal intraocular foreign body resulting in cyclodialysis cleft
title_full Retina-sparing suprachoroidal intraocular foreign body resulting in cyclodialysis cleft
title_fullStr Retina-sparing suprachoroidal intraocular foreign body resulting in cyclodialysis cleft
title_full_unstemmed Retina-sparing suprachoroidal intraocular foreign body resulting in cyclodialysis cleft
title_short Retina-sparing suprachoroidal intraocular foreign body resulting in cyclodialysis cleft
title_sort retina-sparing suprachoroidal intraocular foreign body resulting in cyclodialysis cleft
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9095656/
https://www.ncbi.nlm.nih.gov/pubmed/35572608
http://dx.doi.org/10.1016/j.ajoc.2022.101571
work_keys_str_mv AT kanecolinp retinasparingsuprachoroidalintraocularforeignbodyresultingincyclodialysiscleft
AT johnsonthomasv retinasparingsuprachoroidalintraocularforeignbodyresultingincyclodialysiscleft
AT sachdevamiram retinasparingsuprachoroidalintraocularforeignbodyresultingincyclodialysiscleft