Cargando…

Uncertainty analysis of chest X-ray lung height measurements and size matching for lung transplantation

BACKGROUND: Errors in measuring chest X-ray (CXR) lung heights could contribute to the occurrence of size-mismatched lung transplant procedures. METHODS: We first used Bland-Altman analysis for repeated measures to evaluate contributors to measurement error of chest X-ray lung height. We then applie...

Descripción completa

Detalles Bibliográficos
Autores principales: Vazquez Guillamet, Rodrigo, Vazquez Guillamet, Maria C., Rjob, Ashraf, Bierhals, Andrew, Bello, Irene, Abularach, Alberto Jauregui, Tague, Laneshia, Wallendorf, Michael, Marklin, Gary F., Witt, Chad, Byers, Derek E., Kreisel, Daniel, Nava, Ruben, Puri, Varun, Hachem, Ramsey, Trulock, Elbert P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9096316/
https://www.ncbi.nlm.nih.gov/pubmed/35572863
http://dx.doi.org/10.21037/jtd-21-1755
_version_ 1784705949283385344
author Vazquez Guillamet, Rodrigo
Vazquez Guillamet, Maria C.
Rjob, Ashraf
Bierhals, Andrew
Bello, Irene
Abularach, Alberto Jauregui
Tague, Laneshia
Wallendorf, Michael
Marklin, Gary F.
Witt, Chad
Byers, Derek E.
Kreisel, Daniel
Nava, Ruben
Puri, Varun
Hachem, Ramsey
Trulock, Elbert P.
author_facet Vazquez Guillamet, Rodrigo
Vazquez Guillamet, Maria C.
Rjob, Ashraf
Bierhals, Andrew
Bello, Irene
Abularach, Alberto Jauregui
Tague, Laneshia
Wallendorf, Michael
Marklin, Gary F.
Witt, Chad
Byers, Derek E.
Kreisel, Daniel
Nava, Ruben
Puri, Varun
Hachem, Ramsey
Trulock, Elbert P.
author_sort Vazquez Guillamet, Rodrigo
collection PubMed
description BACKGROUND: Errors in measuring chest X-ray (CXR) lung heights could contribute to the occurrence of size-mismatched lung transplant procedures. METHODS: We first used Bland-Altman analysis for repeated measures to evaluate contributors to measurement error of chest X-ray lung height. We then applied error propagation theory to assess the impact of measurement error on size matching for lung transplantation. RESULTS: A total 387 chest X-rays from twenty-five donors and twenty-five recipients were measured by two raters. Individual standard deviation for lung height differences were independent of age, sex, donor vs. recipient, diagnostic group and race/ethnicity and all were pooled for analysis. Bias between raters was 0.27 cm (±0.03) and 0.22 cm (±0.06) for the right and left lung respectively. Within subject variability was the biggest contributor to error in measurement, 2.76 cm (±0.06) and 2.78 cm (±0.2) for the right and left lung height. A height difference of 4.4 cm or more (95% CI: ±4.2, ±4.6 cm) between the donor and the recipient right lung height has to be accepted to ensure matching for at least 95% of patients with the same true lung height. This difference decreases to ±1.1 cm (95% CI: ±0.9, ±1.3 cm) when the average from all available chest X-rays is used. The probability of matching a donor and a recipient decreases with increasing true lung height difference. CONCLUSIONS: Individual chest X-ray lung heights are imprecise for the purpose of size matching in lung transplantation. Averaging chest X-rays lung heights reduced uncertainty.
format Online
Article
Text
id pubmed-9096316
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-90963162022-05-13 Uncertainty analysis of chest X-ray lung height measurements and size matching for lung transplantation Vazquez Guillamet, Rodrigo Vazquez Guillamet, Maria C. Rjob, Ashraf Bierhals, Andrew Bello, Irene Abularach, Alberto Jauregui Tague, Laneshia Wallendorf, Michael Marklin, Gary F. Witt, Chad Byers, Derek E. Kreisel, Daniel Nava, Ruben Puri, Varun Hachem, Ramsey Trulock, Elbert P. J Thorac Dis Original Article BACKGROUND: Errors in measuring chest X-ray (CXR) lung heights could contribute to the occurrence of size-mismatched lung transplant procedures. METHODS: We first used Bland-Altman analysis for repeated measures to evaluate contributors to measurement error of chest X-ray lung height. We then applied error propagation theory to assess the impact of measurement error on size matching for lung transplantation. RESULTS: A total 387 chest X-rays from twenty-five donors and twenty-five recipients were measured by two raters. Individual standard deviation for lung height differences were independent of age, sex, donor vs. recipient, diagnostic group and race/ethnicity and all were pooled for analysis. Bias between raters was 0.27 cm (±0.03) and 0.22 cm (±0.06) for the right and left lung respectively. Within subject variability was the biggest contributor to error in measurement, 2.76 cm (±0.06) and 2.78 cm (±0.2) for the right and left lung height. A height difference of 4.4 cm or more (95% CI: ±4.2, ±4.6 cm) between the donor and the recipient right lung height has to be accepted to ensure matching for at least 95% of patients with the same true lung height. This difference decreases to ±1.1 cm (95% CI: ±0.9, ±1.3 cm) when the average from all available chest X-rays is used. The probability of matching a donor and a recipient decreases with increasing true lung height difference. CONCLUSIONS: Individual chest X-ray lung heights are imprecise for the purpose of size matching in lung transplantation. Averaging chest X-rays lung heights reduced uncertainty. AME Publishing Company 2022-04 /pmc/articles/PMC9096316/ /pubmed/35572863 http://dx.doi.org/10.21037/jtd-21-1755 Text en 2022 Journal of Thoracic Disease. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Vazquez Guillamet, Rodrigo
Vazquez Guillamet, Maria C.
Rjob, Ashraf
Bierhals, Andrew
Bello, Irene
Abularach, Alberto Jauregui
Tague, Laneshia
Wallendorf, Michael
Marklin, Gary F.
Witt, Chad
Byers, Derek E.
Kreisel, Daniel
Nava, Ruben
Puri, Varun
Hachem, Ramsey
Trulock, Elbert P.
Uncertainty analysis of chest X-ray lung height measurements and size matching for lung transplantation
title Uncertainty analysis of chest X-ray lung height measurements and size matching for lung transplantation
title_full Uncertainty analysis of chest X-ray lung height measurements and size matching for lung transplantation
title_fullStr Uncertainty analysis of chest X-ray lung height measurements and size matching for lung transplantation
title_full_unstemmed Uncertainty analysis of chest X-ray lung height measurements and size matching for lung transplantation
title_short Uncertainty analysis of chest X-ray lung height measurements and size matching for lung transplantation
title_sort uncertainty analysis of chest x-ray lung height measurements and size matching for lung transplantation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9096316/
https://www.ncbi.nlm.nih.gov/pubmed/35572863
http://dx.doi.org/10.21037/jtd-21-1755
work_keys_str_mv AT vazquezguillametrodrigo uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT vazquezguillametmariac uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT rjobashraf uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT bierhalsandrew uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT belloirene uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT abularachalbertojauregui uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT taguelaneshia uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT wallendorfmichael uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT marklingaryf uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT wittchad uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT byersdereke uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT kreiseldaniel uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT navaruben uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT purivarun uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT hachemramsey uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation
AT trulockelbertp uncertaintyanalysisofchestxraylungheightmeasurementsandsizematchingforlungtransplantation