Cargando…
New adjustable modular hemipelvic prosthesis replacement with 3D-print osteotomy guide plate used in periacetabular malignant tumors: a retrospective case series
BACKGROUND: Periacetabular malignant tumor seriously endangers the life and health of patients. Hemipelvic replacement provides a good method for patients who want complete resection of the tumor while retaining or restoring the function of the affected limb. OBJECTIVE: To investigate the performanc...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9097406/ https://www.ncbi.nlm.nih.gov/pubmed/35551637 http://dx.doi.org/10.1186/s13018-022-03150-0 |
_version_ | 1784706170419675136 |
---|---|
author | Li, Jun Liu, Zicheng Peng, Dan Chen, Xia Yu, Chao Shen, Yi |
author_facet | Li, Jun Liu, Zicheng Peng, Dan Chen, Xia Yu, Chao Shen, Yi |
author_sort | Li, Jun |
collection | PubMed |
description | BACKGROUND: Periacetabular malignant tumor seriously endangers the life and health of patients. Hemipelvic replacement provides a good method for patients who want complete resection of the tumor while retaining or restoring the function of the affected limb. OBJECTIVE: To investigate the performance and clinical application of the new adjustable modular hemipelvic prosthesis and to compare the effects of three kinds of hemipelvic prosthesis. METHODS: In this study, 23 patients, with an average age of 44.6 years (21–75 years), were collected, who received hemipelvic replacement with new adjustable, modular, and screw-rod system hemipelvic prosthesis. Preoperative preparation was conducted on them, and operative complications were recorded. Postoperative functional follow-up was performed regularly. RESULTS: The average operation time was 319 min (170–480 min), and the average blood loss was 2813 ml (1000 mL-8000 ml). The incidence of complications was 47.8%, and type A (wound-related complications) had the highest incidence (34.8%). Postoperative dislocation occurred in 3 cases (13.0%), and no dislocation occurred in the new adjustable modular hemipelvic prosthesis group. The average MSTS score of the patients was 18.6 (10–23), and the average Harris score was 73.7 (53–87). CONCLUSIONS: The new adjustable modular hemipelvic prosthesis has the feasibility of reconstruction and good functional outcome, making it ideal for periacetabular tumors. Furthermore, preoperative tumor-feeding artery embolization and abdominal aortic balloon implantation may be an effective choice to reduce intraoperative blood loss and facilitate the operation of tumor resection. |
format | Online Article Text |
id | pubmed-9097406 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-90974062022-05-13 New adjustable modular hemipelvic prosthesis replacement with 3D-print osteotomy guide plate used in periacetabular malignant tumors: a retrospective case series Li, Jun Liu, Zicheng Peng, Dan Chen, Xia Yu, Chao Shen, Yi J Orthop Surg Res Research Article BACKGROUND: Periacetabular malignant tumor seriously endangers the life and health of patients. Hemipelvic replacement provides a good method for patients who want complete resection of the tumor while retaining or restoring the function of the affected limb. OBJECTIVE: To investigate the performance and clinical application of the new adjustable modular hemipelvic prosthesis and to compare the effects of three kinds of hemipelvic prosthesis. METHODS: In this study, 23 patients, with an average age of 44.6 years (21–75 years), were collected, who received hemipelvic replacement with new adjustable, modular, and screw-rod system hemipelvic prosthesis. Preoperative preparation was conducted on them, and operative complications were recorded. Postoperative functional follow-up was performed regularly. RESULTS: The average operation time was 319 min (170–480 min), and the average blood loss was 2813 ml (1000 mL-8000 ml). The incidence of complications was 47.8%, and type A (wound-related complications) had the highest incidence (34.8%). Postoperative dislocation occurred in 3 cases (13.0%), and no dislocation occurred in the new adjustable modular hemipelvic prosthesis group. The average MSTS score of the patients was 18.6 (10–23), and the average Harris score was 73.7 (53–87). CONCLUSIONS: The new adjustable modular hemipelvic prosthesis has the feasibility of reconstruction and good functional outcome, making it ideal for periacetabular tumors. Furthermore, preoperative tumor-feeding artery embolization and abdominal aortic balloon implantation may be an effective choice to reduce intraoperative blood loss and facilitate the operation of tumor resection. BioMed Central 2022-05-12 /pmc/articles/PMC9097406/ /pubmed/35551637 http://dx.doi.org/10.1186/s13018-022-03150-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Li, Jun Liu, Zicheng Peng, Dan Chen, Xia Yu, Chao Shen, Yi New adjustable modular hemipelvic prosthesis replacement with 3D-print osteotomy guide plate used in periacetabular malignant tumors: a retrospective case series |
title | New adjustable modular hemipelvic prosthesis replacement with 3D-print osteotomy guide plate used in periacetabular malignant tumors: a retrospective case series |
title_full | New adjustable modular hemipelvic prosthesis replacement with 3D-print osteotomy guide plate used in periacetabular malignant tumors: a retrospective case series |
title_fullStr | New adjustable modular hemipelvic prosthesis replacement with 3D-print osteotomy guide plate used in periacetabular malignant tumors: a retrospective case series |
title_full_unstemmed | New adjustable modular hemipelvic prosthesis replacement with 3D-print osteotomy guide plate used in periacetabular malignant tumors: a retrospective case series |
title_short | New adjustable modular hemipelvic prosthesis replacement with 3D-print osteotomy guide plate used in periacetabular malignant tumors: a retrospective case series |
title_sort | new adjustable modular hemipelvic prosthesis replacement with 3d-print osteotomy guide plate used in periacetabular malignant tumors: a retrospective case series |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9097406/ https://www.ncbi.nlm.nih.gov/pubmed/35551637 http://dx.doi.org/10.1186/s13018-022-03150-0 |
work_keys_str_mv | AT lijun newadjustablemodularhemipelvicprosthesisreplacementwith3dprintosteotomyguideplateusedinperiacetabularmalignanttumorsaretrospectivecaseseries AT liuzicheng newadjustablemodularhemipelvicprosthesisreplacementwith3dprintosteotomyguideplateusedinperiacetabularmalignanttumorsaretrospectivecaseseries AT pengdan newadjustablemodularhemipelvicprosthesisreplacementwith3dprintosteotomyguideplateusedinperiacetabularmalignanttumorsaretrospectivecaseseries AT chenxia newadjustablemodularhemipelvicprosthesisreplacementwith3dprintosteotomyguideplateusedinperiacetabularmalignanttumorsaretrospectivecaseseries AT yuchao newadjustablemodularhemipelvicprosthesisreplacementwith3dprintosteotomyguideplateusedinperiacetabularmalignanttumorsaretrospectivecaseseries AT shenyi newadjustablemodularhemipelvicprosthesisreplacementwith3dprintosteotomyguideplateusedinperiacetabularmalignanttumorsaretrospectivecaseseries |