Cargando…

Selective Fe(ii)-fluorescence sensor with validated two-consecutive working range using N,S,I-GQDs associated with garlic extract as an auxiliary green chelating agent

The goal of this work was to use the pyrolysis process to synthesize graphene quantum dots doped with garlic extract (as N,S-GQDs) and simultaneously co-doped with iodine (as I-GQDs). XPS, HR-TEM, FE-SEM/EDX, FT-IR, fluorescence, and UV-visible absorption spectroscopy were used to characterize the N...

Descripción completa

Detalles Bibliográficos
Autores principales: Pimsin, Nipaporn, Keawprom, Chayanee, Areerob, Yonrapach, Limchoowong, Nunticha, Sricharoen, Phitchan, Nuengmatcha, Prawit, Oh, Won-Chun, Chanthai, Saksit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9097786/
https://www.ncbi.nlm.nih.gov/pubmed/35702222
http://dx.doi.org/10.1039/d2ra01381a
Descripción
Sumario:The goal of this work was to use the pyrolysis process to synthesize graphene quantum dots doped with garlic extract (as N,S-GQDs) and simultaneously co-doped with iodine (as I-GQDs). XPS, HR-TEM, FE-SEM/EDX, FT-IR, fluorescence, and UV-visible absorption spectroscopy were used to characterize the N,S,I-GQDs and analyze their morphological images. The quantum yield of N,S,I-GQDs was found to be 45%, greater than that of undoped GQDs (31%). When stimulated at 363 nm, the N,S,I-GQDs display a strong fluorescence intensity at a maximum wavelength of 454 nm. Using N,S,I-GQDs as a fluorescence quenching sensor for screening tests with various metal ions, it was discovered that they are extremely selective towards Fe(2+) over Fe(3+) and other ions. Thus, solution pH, concentration of N,S,I-GQDs, quantity of garlic extract, EDTA and AgNO(3) concentration as masking agents, reaction duration under ultrasonic aid, and tolerable limit of Fe(3+) presence in the target analyte were all optimized for Fe(2+) detection. A highly sensitive detection of Fe(2+) was obtained using a linear curve with y = 141.34x + 5.5855, R(2) = 0.9961, LOD = 0.11 mg L(−1), and LOQ = 0.35 mg L(−1). The method precision, given as RSDs, was determined to be satisfactory at 1.04% for intra-day analysis and 3.22% for inter-day analysis, respectively. As a result, the selective determination of trace amounts of Fe(2+) in real water samples using such labile multi-element doped GQDs in conjunction with garlic extract as a green chelating agent to maintain its enhanced sensitivity was successfully applied with good recoveries ranging from 89.16 to 121.45%.