Cargando…

Transaxillary Versus Transaortic Transcatheter Aortic Valve Implantation in the Treatment of Aortic Stenosis: An Updated Systematic Review and Meta-Analysis

Transcatheter aortic valve replacement (TAVR) is a technique that can be performed through multiple approaches, and the benefits of one approach over another are still being evaluated to make sure patients receive the best possible care. Our meta-analysis aims to compare clinical and procedural outc...

Descripción completa

Detalles Bibliográficos
Autores principales: Hameed, Ishaque, Khan, Mohammad O, Ul-Haque, Ibtehaj, Siddiqui, Omer M, Samad, Syed A, Malik, Shanza, Mahmood, Samar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9097931/
https://www.ncbi.nlm.nih.gov/pubmed/35573526
http://dx.doi.org/10.7759/cureus.24054
_version_ 1784706271895617536
author Hameed, Ishaque
Khan, Mohammad O
Ul-Haque, Ibtehaj
Siddiqui, Omer M
Samad, Syed A
Malik, Shanza
Mahmood, Samar
author_facet Hameed, Ishaque
Khan, Mohammad O
Ul-Haque, Ibtehaj
Siddiqui, Omer M
Samad, Syed A
Malik, Shanza
Mahmood, Samar
author_sort Hameed, Ishaque
collection PubMed
description Transcatheter aortic valve replacement (TAVR) is a technique that can be performed through multiple approaches, and the benefits of one approach over another are still being evaluated to make sure patients receive the best possible care. Our meta-analysis aims to compare clinical and procedural outcomes of the transaxillary (TAx) and transaortic (TAo) approaches to validate the more optimal procedure. The systematic literature search was done via PubMed/MEDLINE, Embase, and the Cochrane Central databases from inception to December 2021, to identify articles reporting data on both TAx TAVR and TAo TAVR. In addition, we checked ClinicalTrials.gov for more published or unpublished trials. Baseline patient characteristics, procedure results, and clinical results were extracted from the article and pooled for analysis. A quantitative meta-analysis was conducted using Review Manager (RevMan) version 5.3 (Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). The outcomes extracted included blood transfusion, conversion to sternotomy, tamponade, contrast amount, procedure time, bleeding incidents (minor, major, or life-threatening), length of stay (LOS), vascular complications (minor or major), acute kidney injury (AKI), paravalvular leak (PVL), permanent pacemaker (PPM) implantation, 30-day mortality, one-year mortality, 30-day stroke, and device success. The final analysis included 11 articles, consisting of 10 observational studies and a pivotal trial. Cumulative results revealed that the TAo approach had a significantly lower incidence of vascular complications (RR = 2.30; 95% CI = 1.22 to 4.35), and the need for implantation of a permanent pacemaker (RR = 1.82; 95% CI = 1.30 to 2.54) along with a lower amount of contrast (mean difference (MD) = 27.40; 95% CI = 3.73 to 51.08) needed to be used. The TAx group was associated with a significantly lower 30-day mortality (RR = 0.46; 95% CI = 0.31 to 0.69), AKI (RR = 0.47; 95% CI = 0.33 to 0.67), and length of hospital stay (MD = −1.95; 95% CI = −2.51 to −1.38). No significant difference was observed between the outcomes of 30-day stroke (RR = 1.38; 95% CI = 0.81 to 2.33), PVL (RR = 1.05; 95% CI = 0.50 to 2.18), tamponade (RR = 0.71; 95% CI = 0.12 to 4.03), conversion to sternotomy (RR = 0.51; 95% CI = 0.06 to 4.30), device success (RR = 0.97; 95% CI = 0.88 to 1.07), the incidence of bleeding (RR = 0.75; 95% CI = 0.51 to 1.10), and procedure time (MD = 4.44; 95% CI = −96.30 to 105.17). Both the procedures were associated with their benefits and risks. Although most of the outcomes favored TAx transcatheter aortic valve implantation (TAVI), it is too early to say if it would be better than TAo TAVI. To authenticate the findings concluded in this meta-analysis and further improve our understanding of the efficacy, safety, and risk profile between TAx and TAo approaches for TAVI, large sample randomized clinical trials are required on a wide scale.
format Online
Article
Text
id pubmed-9097931
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-90979312022-05-14 Transaxillary Versus Transaortic Transcatheter Aortic Valve Implantation in the Treatment of Aortic Stenosis: An Updated Systematic Review and Meta-Analysis Hameed, Ishaque Khan, Mohammad O Ul-Haque, Ibtehaj Siddiqui, Omer M Samad, Syed A Malik, Shanza Mahmood, Samar Cureus Cardiac/Thoracic/Vascular Surgery Transcatheter aortic valve replacement (TAVR) is a technique that can be performed through multiple approaches, and the benefits of one approach over another are still being evaluated to make sure patients receive the best possible care. Our meta-analysis aims to compare clinical and procedural outcomes of the transaxillary (TAx) and transaortic (TAo) approaches to validate the more optimal procedure. The systematic literature search was done via PubMed/MEDLINE, Embase, and the Cochrane Central databases from inception to December 2021, to identify articles reporting data on both TAx TAVR and TAo TAVR. In addition, we checked ClinicalTrials.gov for more published or unpublished trials. Baseline patient characteristics, procedure results, and clinical results were extracted from the article and pooled for analysis. A quantitative meta-analysis was conducted using Review Manager (RevMan) version 5.3 (Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). The outcomes extracted included blood transfusion, conversion to sternotomy, tamponade, contrast amount, procedure time, bleeding incidents (minor, major, or life-threatening), length of stay (LOS), vascular complications (minor or major), acute kidney injury (AKI), paravalvular leak (PVL), permanent pacemaker (PPM) implantation, 30-day mortality, one-year mortality, 30-day stroke, and device success. The final analysis included 11 articles, consisting of 10 observational studies and a pivotal trial. Cumulative results revealed that the TAo approach had a significantly lower incidence of vascular complications (RR = 2.30; 95% CI = 1.22 to 4.35), and the need for implantation of a permanent pacemaker (RR = 1.82; 95% CI = 1.30 to 2.54) along with a lower amount of contrast (mean difference (MD) = 27.40; 95% CI = 3.73 to 51.08) needed to be used. The TAx group was associated with a significantly lower 30-day mortality (RR = 0.46; 95% CI = 0.31 to 0.69), AKI (RR = 0.47; 95% CI = 0.33 to 0.67), and length of hospital stay (MD = −1.95; 95% CI = −2.51 to −1.38). No significant difference was observed between the outcomes of 30-day stroke (RR = 1.38; 95% CI = 0.81 to 2.33), PVL (RR = 1.05; 95% CI = 0.50 to 2.18), tamponade (RR = 0.71; 95% CI = 0.12 to 4.03), conversion to sternotomy (RR = 0.51; 95% CI = 0.06 to 4.30), device success (RR = 0.97; 95% CI = 0.88 to 1.07), the incidence of bleeding (RR = 0.75; 95% CI = 0.51 to 1.10), and procedure time (MD = 4.44; 95% CI = −96.30 to 105.17). Both the procedures were associated with their benefits and risks. Although most of the outcomes favored TAx transcatheter aortic valve implantation (TAVI), it is too early to say if it would be better than TAo TAVI. To authenticate the findings concluded in this meta-analysis and further improve our understanding of the efficacy, safety, and risk profile between TAx and TAo approaches for TAVI, large sample randomized clinical trials are required on a wide scale. Cureus 2022-04-12 /pmc/articles/PMC9097931/ /pubmed/35573526 http://dx.doi.org/10.7759/cureus.24054 Text en Copyright © 2022, Hameed et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiac/Thoracic/Vascular Surgery
Hameed, Ishaque
Khan, Mohammad O
Ul-Haque, Ibtehaj
Siddiqui, Omer M
Samad, Syed A
Malik, Shanza
Mahmood, Samar
Transaxillary Versus Transaortic Transcatheter Aortic Valve Implantation in the Treatment of Aortic Stenosis: An Updated Systematic Review and Meta-Analysis
title Transaxillary Versus Transaortic Transcatheter Aortic Valve Implantation in the Treatment of Aortic Stenosis: An Updated Systematic Review and Meta-Analysis
title_full Transaxillary Versus Transaortic Transcatheter Aortic Valve Implantation in the Treatment of Aortic Stenosis: An Updated Systematic Review and Meta-Analysis
title_fullStr Transaxillary Versus Transaortic Transcatheter Aortic Valve Implantation in the Treatment of Aortic Stenosis: An Updated Systematic Review and Meta-Analysis
title_full_unstemmed Transaxillary Versus Transaortic Transcatheter Aortic Valve Implantation in the Treatment of Aortic Stenosis: An Updated Systematic Review and Meta-Analysis
title_short Transaxillary Versus Transaortic Transcatheter Aortic Valve Implantation in the Treatment of Aortic Stenosis: An Updated Systematic Review and Meta-Analysis
title_sort transaxillary versus transaortic transcatheter aortic valve implantation in the treatment of aortic stenosis: an updated systematic review and meta-analysis
topic Cardiac/Thoracic/Vascular Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9097931/
https://www.ncbi.nlm.nih.gov/pubmed/35573526
http://dx.doi.org/10.7759/cureus.24054
work_keys_str_mv AT hameedishaque transaxillaryversustransaortictranscatheteraorticvalveimplantationinthetreatmentofaorticstenosisanupdatedsystematicreviewandmetaanalysis
AT khanmohammado transaxillaryversustransaortictranscatheteraorticvalveimplantationinthetreatmentofaorticstenosisanupdatedsystematicreviewandmetaanalysis
AT ulhaqueibtehaj transaxillaryversustransaortictranscatheteraorticvalveimplantationinthetreatmentofaorticstenosisanupdatedsystematicreviewandmetaanalysis
AT siddiquiomerm transaxillaryversustransaortictranscatheteraorticvalveimplantationinthetreatmentofaorticstenosisanupdatedsystematicreviewandmetaanalysis
AT samadsyeda transaxillaryversustransaortictranscatheteraorticvalveimplantationinthetreatmentofaorticstenosisanupdatedsystematicreviewandmetaanalysis
AT malikshanza transaxillaryversustransaortictranscatheteraorticvalveimplantationinthetreatmentofaorticstenosisanupdatedsystematicreviewandmetaanalysis
AT mahmoodsamar transaxillaryversustransaortictranscatheteraorticvalveimplantationinthetreatmentofaorticstenosisanupdatedsystematicreviewandmetaanalysis