Cargando…

Influence of insole material density in the stability of patients with prosthetic unilateral transtibial amputation

People with lower limb amputation present greater displacements of their centre of gravity in a static situation than able-bodied individuals, as they depend on visual information to a greater extent, which implies an altered stability pattern. The efficacy of different hardness of plantar support t...

Descripción completa

Detalles Bibliográficos
Autores principales: Sarroca, Nuria, Luesma, María José, Valero, José, del Caso, María Pilar, Alonso, Cristina, Calleja, Jorge, Lorenzo, Tania, Bayod, Javier, Lahoz, Manuel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9098549/
https://www.ncbi.nlm.nih.gov/pubmed/35552421
http://dx.doi.org/10.1038/s41598-022-11564-3
_version_ 1784706409856761856
author Sarroca, Nuria
Luesma, María José
Valero, José
del Caso, María Pilar
Alonso, Cristina
Calleja, Jorge
Lorenzo, Tania
Bayod, Javier
Lahoz, Manuel
author_facet Sarroca, Nuria
Luesma, María José
Valero, José
del Caso, María Pilar
Alonso, Cristina
Calleja, Jorge
Lorenzo, Tania
Bayod, Javier
Lahoz, Manuel
author_sort Sarroca, Nuria
collection PubMed
description People with lower limb amputation present greater displacements of their centre of gravity in a static situation than able-bodied individuals, as they depend on visual information to a greater extent, which implies an altered stability pattern. The efficacy of different hardness of plantar support to help maintain stability has not yet been determined. The aim of the present study is to assess stability in people with unilateral transtibial amputation with prosthesis in a static situation with insoles of different degrees of hardness and visual conditions with respect to the able-bodied population. For this purpose, 25 patients with amputation and 25 able-bodied individuals were included in both groups, postural stability was assessed by stabilometry. This assessment was carried out under normal conditions (on the floor of the dynamometric platform with eyes open), and under altered conditions (with the interposition of different materials such as plantar support: rigid and soft insoles and, eyes shut). Three variables were considered to assess stability: length of movement of the barycenter (mm), lateral velocity (mm/sg) and anterior velocity (mm/sg). All of them were analysed with the patient in static on the dynamometric platform. The results showed statistically significant differences between the two groups, (amputees and controls) with less stability in the amputee group (p < 0.05) when analysing the variables of length of movement of the barycenter, lateral velocity and anterior velocity. Amputee patients with open eyes exhibited greater stability than those with closed eyes. The hard insoles improved the stability data in amputees (length of movement of the barycenter and anterior velocity) with respect to the barefoot condition, and the soft insoles showed less stability than the patients with hard insoles, or than the barefoot patients. From the results obtained in this study, we can conclude that the PP-DWST 4 mm rigid insoles improve static stability in people with amputation. However, soft insoles impair stability and are therefore discouraged.
format Online
Article
Text
id pubmed-9098549
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-90985492022-05-14 Influence of insole material density in the stability of patients with prosthetic unilateral transtibial amputation Sarroca, Nuria Luesma, María José Valero, José del Caso, María Pilar Alonso, Cristina Calleja, Jorge Lorenzo, Tania Bayod, Javier Lahoz, Manuel Sci Rep Article People with lower limb amputation present greater displacements of their centre of gravity in a static situation than able-bodied individuals, as they depend on visual information to a greater extent, which implies an altered stability pattern. The efficacy of different hardness of plantar support to help maintain stability has not yet been determined. The aim of the present study is to assess stability in people with unilateral transtibial amputation with prosthesis in a static situation with insoles of different degrees of hardness and visual conditions with respect to the able-bodied population. For this purpose, 25 patients with amputation and 25 able-bodied individuals were included in both groups, postural stability was assessed by stabilometry. This assessment was carried out under normal conditions (on the floor of the dynamometric platform with eyes open), and under altered conditions (with the interposition of different materials such as plantar support: rigid and soft insoles and, eyes shut). Three variables were considered to assess stability: length of movement of the barycenter (mm), lateral velocity (mm/sg) and anterior velocity (mm/sg). All of them were analysed with the patient in static on the dynamometric platform. The results showed statistically significant differences between the two groups, (amputees and controls) with less stability in the amputee group (p < 0.05) when analysing the variables of length of movement of the barycenter, lateral velocity and anterior velocity. Amputee patients with open eyes exhibited greater stability than those with closed eyes. The hard insoles improved the stability data in amputees (length of movement of the barycenter and anterior velocity) with respect to the barefoot condition, and the soft insoles showed less stability than the patients with hard insoles, or than the barefoot patients. From the results obtained in this study, we can conclude that the PP-DWST 4 mm rigid insoles improve static stability in people with amputation. However, soft insoles impair stability and are therefore discouraged. Nature Publishing Group UK 2022-05-12 /pmc/articles/PMC9098549/ /pubmed/35552421 http://dx.doi.org/10.1038/s41598-022-11564-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Sarroca, Nuria
Luesma, María José
Valero, José
del Caso, María Pilar
Alonso, Cristina
Calleja, Jorge
Lorenzo, Tania
Bayod, Javier
Lahoz, Manuel
Influence of insole material density in the stability of patients with prosthetic unilateral transtibial amputation
title Influence of insole material density in the stability of patients with prosthetic unilateral transtibial amputation
title_full Influence of insole material density in the stability of patients with prosthetic unilateral transtibial amputation
title_fullStr Influence of insole material density in the stability of patients with prosthetic unilateral transtibial amputation
title_full_unstemmed Influence of insole material density in the stability of patients with prosthetic unilateral transtibial amputation
title_short Influence of insole material density in the stability of patients with prosthetic unilateral transtibial amputation
title_sort influence of insole material density in the stability of patients with prosthetic unilateral transtibial amputation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9098549/
https://www.ncbi.nlm.nih.gov/pubmed/35552421
http://dx.doi.org/10.1038/s41598-022-11564-3
work_keys_str_mv AT sarrocanuria influenceofinsolematerialdensityinthestabilityofpatientswithprostheticunilateraltranstibialamputation
AT luesmamariajose influenceofinsolematerialdensityinthestabilityofpatientswithprostheticunilateraltranstibialamputation
AT valerojose influenceofinsolematerialdensityinthestabilityofpatientswithprostheticunilateraltranstibialamputation
AT delcasomariapilar influenceofinsolematerialdensityinthestabilityofpatientswithprostheticunilateraltranstibialamputation
AT alonsocristina influenceofinsolematerialdensityinthestabilityofpatientswithprostheticunilateraltranstibialamputation
AT callejajorge influenceofinsolematerialdensityinthestabilityofpatientswithprostheticunilateraltranstibialamputation
AT lorenzotania influenceofinsolematerialdensityinthestabilityofpatientswithprostheticunilateraltranstibialamputation
AT bayodjavier influenceofinsolematerialdensityinthestabilityofpatientswithprostheticunilateraltranstibialamputation
AT lahozmanuel influenceofinsolematerialdensityinthestabilityofpatientswithprostheticunilateraltranstibialamputation