Cargando…

Within and Between Subject Spectral Fingerprints of EEG-Microstate Parameters

Early reports have claimed that EEG microstate features (e.g. their mean duration or percent of time covered) are largely independent from EEG spectra. This has meanwhile been questioned for conceptual and empirical reasons, but so far, EEG spectral power map correlates of microstate features have n...

Descripción completa

Detalles Bibliográficos
Autores principales: Zulliger, Johannes, Diaz Hernandez, Laura, Koenig, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9098597/
https://www.ncbi.nlm.nih.gov/pubmed/35414139
http://dx.doi.org/10.1007/s10548-022-00896-y
_version_ 1784706421249540096
author Zulliger, Johannes
Diaz Hernandez, Laura
Koenig, Thomas
author_facet Zulliger, Johannes
Diaz Hernandez, Laura
Koenig, Thomas
author_sort Zulliger, Johannes
collection PubMed
description Early reports have claimed that EEG microstate features (e.g. their mean duration or percent of time covered) are largely independent from EEG spectra. This has meanwhile been questioned for conceptual and empirical reasons, but so far, EEG spectral power map correlates of microstate features have not been reported. We present the results of such analyses, conducted both within and between subjects, and report patterns of systematic changes in local EEG spectral amplitude associated with the mean duration, frequency of occurrence and relative contribution of particular microstate classes. The combination of EEG microstate analysis with spectral analysis may therefore be helpful to come to a deeper understanding of local patterns of activation and inhibition associated with particular microstate classes.
format Online
Article
Text
id pubmed-9098597
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-90985972022-05-14 Within and Between Subject Spectral Fingerprints of EEG-Microstate Parameters Zulliger, Johannes Diaz Hernandez, Laura Koenig, Thomas Brain Topogr Brrief Communication Early reports have claimed that EEG microstate features (e.g. their mean duration or percent of time covered) are largely independent from EEG spectra. This has meanwhile been questioned for conceptual and empirical reasons, but so far, EEG spectral power map correlates of microstate features have not been reported. We present the results of such analyses, conducted both within and between subjects, and report patterns of systematic changes in local EEG spectral amplitude associated with the mean duration, frequency of occurrence and relative contribution of particular microstate classes. The combination of EEG microstate analysis with spectral analysis may therefore be helpful to come to a deeper understanding of local patterns of activation and inhibition associated with particular microstate classes. Springer US 2022-04-12 2022 /pmc/articles/PMC9098597/ /pubmed/35414139 http://dx.doi.org/10.1007/s10548-022-00896-y Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Brrief Communication
Zulliger, Johannes
Diaz Hernandez, Laura
Koenig, Thomas
Within and Between Subject Spectral Fingerprints of EEG-Microstate Parameters
title Within and Between Subject Spectral Fingerprints of EEG-Microstate Parameters
title_full Within and Between Subject Spectral Fingerprints of EEG-Microstate Parameters
title_fullStr Within and Between Subject Spectral Fingerprints of EEG-Microstate Parameters
title_full_unstemmed Within and Between Subject Spectral Fingerprints of EEG-Microstate Parameters
title_short Within and Between Subject Spectral Fingerprints of EEG-Microstate Parameters
title_sort within and between subject spectral fingerprints of eeg-microstate parameters
topic Brrief Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9098597/
https://www.ncbi.nlm.nih.gov/pubmed/35414139
http://dx.doi.org/10.1007/s10548-022-00896-y
work_keys_str_mv AT zulligerjohannes withinandbetweensubjectspectralfingerprintsofeegmicrostateparameters
AT diazhernandezlaura withinandbetweensubjectspectralfingerprintsofeegmicrostateparameters
AT koenigthomas withinandbetweensubjectspectralfingerprintsofeegmicrostateparameters