Cargando…

Comparison of the performance of MS enteroscope series and Japanese double- and single-balloon enteroscopes

BACKGROUND: Small intestine disease endangers human health and is not easy to locate and diagnose. AIM: To observe the effect of the MS series of small intestine endoscopes on the gastrointestinal tract, the changes in serum gastrin levels and intestinal tissue, and the time required for the examina...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Jin-Hua, Liu, Dan-Yang, Yuan, Yong-Feng, Sun, Xue-Jun, Shan, Shu-Mei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9099188/
https://www.ncbi.nlm.nih.gov/pubmed/35645541
http://dx.doi.org/10.3748/wjg.v28.i13.1329
_version_ 1784706548398817280
author Liu, Jin-Hua
Liu, Dan-Yang
Yuan, Yong-Feng
Sun, Xue-Jun
Shan, Shu-Mei
author_facet Liu, Jin-Hua
Liu, Dan-Yang
Yuan, Yong-Feng
Sun, Xue-Jun
Shan, Shu-Mei
author_sort Liu, Jin-Hua
collection PubMed
description BACKGROUND: Small intestine disease endangers human health and is not easy to locate and diagnose. AIM: To observe the effect of the MS series of small intestine endoscopes on the gastrointestinal tract, the changes in serum gastrin levels and intestinal tissue, and the time required for the examination. METHODS: In vivo experiments in 20 Living pigs were conducted, Bowel preparation was routinely performed, Intravenous anesthesia with propofol and ketamine was applied, the condition of the small intestine was observed and the detection time of the MS series of small intestine endoscopes were recorded, The changes in intestinal tissue using the MS series of small intestine endoscopes observed and compared before and after the examination, Venous blood (3-5 mL) from pigs was collected before and after the experiment; changes in intestinal tissue after use of the MS series of small intestine endoscopes observed after examination. After completion of each type of small intestine endoscope experiment, the pigs were allowed to rest and the next type of small intestine endoscope experiment was performed after 15 days of normal feeding. The detection time data of the single-balloon small intestine endoscope and double-balloon small intestine endoscope were collected from four hospitals. RESULTS: One case of Ascarislumbricoides, one of suspected Crohn's disease, one small intestinal diverticulum and one anesthesia accident were observed in pigs. The small intestine showed no differences in the MS series of small intestine endoscopes and there were no differences in serum gastrin between the groups (P > 0.05). The time required for inspection was recorded, and the overall detection time for the Japanese small intestine endoscopes was approximately 1.68 ± 0.16 h. CONCLUSION: Intestinal ascariasis is a common disease in pigs. Some pigs have abnormal intestinal variation. After continuous upgrade and improvement, the MS-3 and MS-4 small intestine endoscope appear superior in terms of detection time.
format Online
Article
Text
id pubmed-9099188
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-90991882022-05-26 Comparison of the performance of MS enteroscope series and Japanese double- and single-balloon enteroscopes Liu, Jin-Hua Liu, Dan-Yang Yuan, Yong-Feng Sun, Xue-Jun Shan, Shu-Mei World J Gastroenterol Basic Study BACKGROUND: Small intestine disease endangers human health and is not easy to locate and diagnose. AIM: To observe the effect of the MS series of small intestine endoscopes on the gastrointestinal tract, the changes in serum gastrin levels and intestinal tissue, and the time required for the examination. METHODS: In vivo experiments in 20 Living pigs were conducted, Bowel preparation was routinely performed, Intravenous anesthesia with propofol and ketamine was applied, the condition of the small intestine was observed and the detection time of the MS series of small intestine endoscopes were recorded, The changes in intestinal tissue using the MS series of small intestine endoscopes observed and compared before and after the examination, Venous blood (3-5 mL) from pigs was collected before and after the experiment; changes in intestinal tissue after use of the MS series of small intestine endoscopes observed after examination. After completion of each type of small intestine endoscope experiment, the pigs were allowed to rest and the next type of small intestine endoscope experiment was performed after 15 days of normal feeding. The detection time data of the single-balloon small intestine endoscope and double-balloon small intestine endoscope were collected from four hospitals. RESULTS: One case of Ascarislumbricoides, one of suspected Crohn's disease, one small intestinal diverticulum and one anesthesia accident were observed in pigs. The small intestine showed no differences in the MS series of small intestine endoscopes and there were no differences in serum gastrin between the groups (P > 0.05). The time required for inspection was recorded, and the overall detection time for the Japanese small intestine endoscopes was approximately 1.68 ± 0.16 h. CONCLUSION: Intestinal ascariasis is a common disease in pigs. Some pigs have abnormal intestinal variation. After continuous upgrade and improvement, the MS-3 and MS-4 small intestine endoscope appear superior in terms of detection time. Baishideng Publishing Group Inc 2022-04-07 2022-04-07 /pmc/articles/PMC9099188/ /pubmed/35645541 http://dx.doi.org/10.3748/wjg.v28.i13.1329 Text en ©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/
spellingShingle Basic Study
Liu, Jin-Hua
Liu, Dan-Yang
Yuan, Yong-Feng
Sun, Xue-Jun
Shan, Shu-Mei
Comparison of the performance of MS enteroscope series and Japanese double- and single-balloon enteroscopes
title Comparison of the performance of MS enteroscope series and Japanese double- and single-balloon enteroscopes
title_full Comparison of the performance of MS enteroscope series and Japanese double- and single-balloon enteroscopes
title_fullStr Comparison of the performance of MS enteroscope series and Japanese double- and single-balloon enteroscopes
title_full_unstemmed Comparison of the performance of MS enteroscope series and Japanese double- and single-balloon enteroscopes
title_short Comparison of the performance of MS enteroscope series and Japanese double- and single-balloon enteroscopes
title_sort comparison of the performance of ms enteroscope series and japanese double- and single-balloon enteroscopes
topic Basic Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9099188/
https://www.ncbi.nlm.nih.gov/pubmed/35645541
http://dx.doi.org/10.3748/wjg.v28.i13.1329
work_keys_str_mv AT liujinhua comparisonoftheperformanceofmsenteroscopeseriesandjapanesedoubleandsingleballoonenteroscopes
AT liudanyang comparisonoftheperformanceofmsenteroscopeseriesandjapanesedoubleandsingleballoonenteroscopes
AT yuanyongfeng comparisonoftheperformanceofmsenteroscopeseriesandjapanesedoubleandsingleballoonenteroscopes
AT sunxuejun comparisonoftheperformanceofmsenteroscopeseriesandjapanesedoubleandsingleballoonenteroscopes
AT shanshumei comparisonoftheperformanceofmsenteroscopeseriesandjapanesedoubleandsingleballoonenteroscopes