Cargando…
The Influence of Face Shields on the Quality of Colonoscopy in the Era of the COVID-19 Pandemic
BACKGROUND/AIMS: The worldwide coronavirus disease 2019 pandemic has led endoscopists to use personal protective equipment (PPE) for infection prevention. This study aimed to investigate whether wearing a face shield as PPE affects the quality of colonoscopy. METHODS: We reviewed the medical records...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Editorial Office of Gut and Liver
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9099398/ https://www.ncbi.nlm.nih.gov/pubmed/34426561 http://dx.doi.org/10.5009/gnl210063 |
_version_ | 1784706596881825792 |
---|---|
author | Lee, Jin Wook Lee, Hyo Jeong Kim, Dae Sung Yoon, Jiyoung Hong, Seung Wook Hwang, Ha Won Lee, Jong-Soo Kim, Gwang-Un Lee, Sinwon Choe, Jaewon Park, Jin Hwa Yang, Dong-Hoon Byeon, Jeong-Sik |
author_facet | Lee, Jin Wook Lee, Hyo Jeong Kim, Dae Sung Yoon, Jiyoung Hong, Seung Wook Hwang, Ha Won Lee, Jong-Soo Kim, Gwang-Un Lee, Sinwon Choe, Jaewon Park, Jin Hwa Yang, Dong-Hoon Byeon, Jeong-Sik |
author_sort | Lee, Jin Wook |
collection | PubMed |
description | BACKGROUND/AIMS: The worldwide coronavirus disease 2019 pandemic has led endoscopists to use personal protective equipment (PPE) for infection prevention. This study aimed to investigate whether wearing a face shield as PPE affects the quality of colonoscopy. METHODS: We reviewed the medical records and colonoscopy findings of patients who underwent colonoscopies at Asan Medical Center, Korea from March 10 to May 31, 2020. The colonoscopies in this study were performed by five gastroenterology fellows and four expert endoscopists. We compared colonoscopy quality indicators, such as withdrawal time, adenoma detection rate (ADR), mean number of adenomas per colonoscopy (APC), polypectomy time, and polypectomy adverse events, both before and after face shields were added as PPE on April 13, 2020. RESULTS: Of the 1,344 colonoscopies analyzed, 715 and 629 were performed before and after the introduction of face shields, respectively. The median withdrawal time was similar between the face shield and no-face shield groups (8.72 minutes vs 8.68 minutes, p=0.816), as was the ADR (41.5% vs 39.8%, p=0.605) and APC (0.72 vs 0.77, p=0.510). Polypectomy-associated quality indicators, such as polypectomy time and polypectomy adverse events were also not different between the groups. Quality indicators were not different between the face shield and no-face shield groups of gastroenterology fellows, or of expert endoscopists. CONCLUSIONS: Colonoscopy performance was not unfavorably affected by the use of a face shield. PPE, including face shields, can be recommended without a concern about colonoscopy quality deterioration. |
format | Online Article Text |
id | pubmed-9099398 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Editorial Office of Gut and Liver |
record_format | MEDLINE/PubMed |
spelling | pubmed-90993982022-05-19 The Influence of Face Shields on the Quality of Colonoscopy in the Era of the COVID-19 Pandemic Lee, Jin Wook Lee, Hyo Jeong Kim, Dae Sung Yoon, Jiyoung Hong, Seung Wook Hwang, Ha Won Lee, Jong-Soo Kim, Gwang-Un Lee, Sinwon Choe, Jaewon Park, Jin Hwa Yang, Dong-Hoon Byeon, Jeong-Sik Gut Liver Original Article BACKGROUND/AIMS: The worldwide coronavirus disease 2019 pandemic has led endoscopists to use personal protective equipment (PPE) for infection prevention. This study aimed to investigate whether wearing a face shield as PPE affects the quality of colonoscopy. METHODS: We reviewed the medical records and colonoscopy findings of patients who underwent colonoscopies at Asan Medical Center, Korea from March 10 to May 31, 2020. The colonoscopies in this study were performed by five gastroenterology fellows and four expert endoscopists. We compared colonoscopy quality indicators, such as withdrawal time, adenoma detection rate (ADR), mean number of adenomas per colonoscopy (APC), polypectomy time, and polypectomy adverse events, both before and after face shields were added as PPE on April 13, 2020. RESULTS: Of the 1,344 colonoscopies analyzed, 715 and 629 were performed before and after the introduction of face shields, respectively. The median withdrawal time was similar between the face shield and no-face shield groups (8.72 minutes vs 8.68 minutes, p=0.816), as was the ADR (41.5% vs 39.8%, p=0.605) and APC (0.72 vs 0.77, p=0.510). Polypectomy-associated quality indicators, such as polypectomy time and polypectomy adverse events were also not different between the groups. Quality indicators were not different between the face shield and no-face shield groups of gastroenterology fellows, or of expert endoscopists. CONCLUSIONS: Colonoscopy performance was not unfavorably affected by the use of a face shield. PPE, including face shields, can be recommended without a concern about colonoscopy quality deterioration. Editorial Office of Gut and Liver 2022-05-15 2021-08-25 /pmc/articles/PMC9099398/ /pubmed/34426561 http://dx.doi.org/10.5009/gnl210063 Text en Copyright © Gut and Liver. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Jin Wook Lee, Hyo Jeong Kim, Dae Sung Yoon, Jiyoung Hong, Seung Wook Hwang, Ha Won Lee, Jong-Soo Kim, Gwang-Un Lee, Sinwon Choe, Jaewon Park, Jin Hwa Yang, Dong-Hoon Byeon, Jeong-Sik The Influence of Face Shields on the Quality of Colonoscopy in the Era of the COVID-19 Pandemic |
title | The Influence of Face Shields on the Quality of Colonoscopy in the Era of the COVID-19 Pandemic |
title_full | The Influence of Face Shields on the Quality of Colonoscopy in the Era of the COVID-19 Pandemic |
title_fullStr | The Influence of Face Shields on the Quality of Colonoscopy in the Era of the COVID-19 Pandemic |
title_full_unstemmed | The Influence of Face Shields on the Quality of Colonoscopy in the Era of the COVID-19 Pandemic |
title_short | The Influence of Face Shields on the Quality of Colonoscopy in the Era of the COVID-19 Pandemic |
title_sort | influence of face shields on the quality of colonoscopy in the era of the covid-19 pandemic |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9099398/ https://www.ncbi.nlm.nih.gov/pubmed/34426561 http://dx.doi.org/10.5009/gnl210063 |
work_keys_str_mv | AT leejinwook theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT leehyojeong theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT kimdaesung theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT yoonjiyoung theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT hongseungwook theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT hwanghawon theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT leejongsoo theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT kimgwangun theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT leesinwon theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT choejaewon theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT parkjinhwa theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT yangdonghoon theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT byeonjeongsik theinfluenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT leejinwook influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT leehyojeong influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT kimdaesung influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT yoonjiyoung influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT hongseungwook influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT hwanghawon influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT leejongsoo influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT kimgwangun influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT leesinwon influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT choejaewon influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT parkjinhwa influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT yangdonghoon influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic AT byeonjeongsik influenceoffaceshieldsonthequalityofcolonoscopyintheeraofthecovid19pandemic |