Comparing the Time-Dependent Evolution of Microcirculation in Gracilis vs. ALT Flaps Using Laser-Doppler Flowmetry and Tissue-Spectrometry

Postoperative free flap monitoring is considered a key component of care after microsurgical reconstruction. To achieve successful flap salvage after surgical revision, early recognition of vascular compromise is required. The aim of this study was to assess and compare the time-dependent evolution...

Descripción completa

Detalles Bibliográficos
Autores principales: Moellhoff, Nicholas, Heidekrueger, Paul I., Frank, Konstantin, Pistek, Svenja, Alt, Verena, Giunta, Riccardo E., Ehrl, Denis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9099565/
https://www.ncbi.nlm.nih.gov/pubmed/35566551
http://dx.doi.org/10.3390/jcm11092425
_version_ 1784706637442842624
author Moellhoff, Nicholas
Heidekrueger, Paul I.
Frank, Konstantin
Pistek, Svenja
Alt, Verena
Giunta, Riccardo E.
Ehrl, Denis
author_facet Moellhoff, Nicholas
Heidekrueger, Paul I.
Frank, Konstantin
Pistek, Svenja
Alt, Verena
Giunta, Riccardo E.
Ehrl, Denis
author_sort Moellhoff, Nicholas
collection PubMed
description Postoperative free flap monitoring is considered a key component of care after microsurgical reconstruction. To achieve successful flap salvage after surgical revision, early recognition of vascular compromise is required. The aim of this study was to assess and compare the time-dependent evolution of microcirculation in gracilis muscle (GM) and anterolateral thigh (ALT) flaps. This study included continuous measurements of blood flow (flow), hemoglobin oxygenation (SO(2)) and the relative amount of hemoglobin (rHb) using laser-doppler flowmetry and tissue-spectrometry (O2C, LEA Medizintechnik, Gießen, Germany) over a time-period of 72 h. Microcirculation was assessed in a total of 66 viable free flaps (GM n = 40; ALT n = 26). A statistically significant positive correlation between time post-anastomosis and microvascular flow was found for both GM and ALT flaps with r(s) = 0.384 (p < 0.001) and r(s) = 0.178 (p = 0.015), respectively. No significant positive or negative correlations between time post-anastomosis and SO(2) were found for both GM and ALT flaps with r(s) = 0.052 (p = 0.387) and r(s) = −0.018 (p = 0.805), respectively. Overall, a significant negative correlation between time post-anastomosis and rHb was found for GM flaps with r(s) = −0.140 (p = 0.019). For ALT flaps, no significant positive or negative correlation was found with r(s) = −0.011 (p = 0.887). Microcirculation differs in different flap entities, and surgeons should be aware of these differences in order to correctly evaluate and classify the values of flow, SO(2) and rHb obtained when using the O2C device for postoperative monitoring.
format Online
Article
Text
id pubmed-9099565
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90995652022-05-14 Comparing the Time-Dependent Evolution of Microcirculation in Gracilis vs. ALT Flaps Using Laser-Doppler Flowmetry and Tissue-Spectrometry Moellhoff, Nicholas Heidekrueger, Paul I. Frank, Konstantin Pistek, Svenja Alt, Verena Giunta, Riccardo E. Ehrl, Denis J Clin Med Article Postoperative free flap monitoring is considered a key component of care after microsurgical reconstruction. To achieve successful flap salvage after surgical revision, early recognition of vascular compromise is required. The aim of this study was to assess and compare the time-dependent evolution of microcirculation in gracilis muscle (GM) and anterolateral thigh (ALT) flaps. This study included continuous measurements of blood flow (flow), hemoglobin oxygenation (SO(2)) and the relative amount of hemoglobin (rHb) using laser-doppler flowmetry and tissue-spectrometry (O2C, LEA Medizintechnik, Gießen, Germany) over a time-period of 72 h. Microcirculation was assessed in a total of 66 viable free flaps (GM n = 40; ALT n = 26). A statistically significant positive correlation between time post-anastomosis and microvascular flow was found for both GM and ALT flaps with r(s) = 0.384 (p < 0.001) and r(s) = 0.178 (p = 0.015), respectively. No significant positive or negative correlations between time post-anastomosis and SO(2) were found for both GM and ALT flaps with r(s) = 0.052 (p = 0.387) and r(s) = −0.018 (p = 0.805), respectively. Overall, a significant negative correlation between time post-anastomosis and rHb was found for GM flaps with r(s) = −0.140 (p = 0.019). For ALT flaps, no significant positive or negative correlation was found with r(s) = −0.011 (p = 0.887). Microcirculation differs in different flap entities, and surgeons should be aware of these differences in order to correctly evaluate and classify the values of flow, SO(2) and rHb obtained when using the O2C device for postoperative monitoring. MDPI 2022-04-26 /pmc/articles/PMC9099565/ /pubmed/35566551 http://dx.doi.org/10.3390/jcm11092425 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Moellhoff, Nicholas
Heidekrueger, Paul I.
Frank, Konstantin
Pistek, Svenja
Alt, Verena
Giunta, Riccardo E.
Ehrl, Denis
Comparing the Time-Dependent Evolution of Microcirculation in Gracilis vs. ALT Flaps Using Laser-Doppler Flowmetry and Tissue-Spectrometry
title Comparing the Time-Dependent Evolution of Microcirculation in Gracilis vs. ALT Flaps Using Laser-Doppler Flowmetry and Tissue-Spectrometry
title_full Comparing the Time-Dependent Evolution of Microcirculation in Gracilis vs. ALT Flaps Using Laser-Doppler Flowmetry and Tissue-Spectrometry
title_fullStr Comparing the Time-Dependent Evolution of Microcirculation in Gracilis vs. ALT Flaps Using Laser-Doppler Flowmetry and Tissue-Spectrometry
title_full_unstemmed Comparing the Time-Dependent Evolution of Microcirculation in Gracilis vs. ALT Flaps Using Laser-Doppler Flowmetry and Tissue-Spectrometry
title_short Comparing the Time-Dependent Evolution of Microcirculation in Gracilis vs. ALT Flaps Using Laser-Doppler Flowmetry and Tissue-Spectrometry
title_sort comparing the time-dependent evolution of microcirculation in gracilis vs. alt flaps using laser-doppler flowmetry and tissue-spectrometry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9099565/
https://www.ncbi.nlm.nih.gov/pubmed/35566551
http://dx.doi.org/10.3390/jcm11092425
work_keys_str_mv AT moellhoffnicholas comparingthetimedependentevolutionofmicrocirculationingracilisvsaltflapsusinglaserdopplerflowmetryandtissuespectrometry
AT heidekruegerpauli comparingthetimedependentevolutionofmicrocirculationingracilisvsaltflapsusinglaserdopplerflowmetryandtissuespectrometry
AT frankkonstantin comparingthetimedependentevolutionofmicrocirculationingracilisvsaltflapsusinglaserdopplerflowmetryandtissuespectrometry
AT pisteksvenja comparingthetimedependentevolutionofmicrocirculationingracilisvsaltflapsusinglaserdopplerflowmetryandtissuespectrometry
AT altverena comparingthetimedependentevolutionofmicrocirculationingracilisvsaltflapsusinglaserdopplerflowmetryandtissuespectrometry
AT giuntariccardoe comparingthetimedependentevolutionofmicrocirculationingracilisvsaltflapsusinglaserdopplerflowmetryandtissuespectrometry
AT ehrldenis comparingthetimedependentevolutionofmicrocirculationingracilisvsaltflapsusinglaserdopplerflowmetryandtissuespectrometry