Cargando…
Analytical Hysteretic Behavior of Square Concrete-Filled Steel Tube Pier Columns under Alternate Sulfate Corrosion and Freeze-Thaw Cycles
The hysteretic behavior of square concrete-filled steel tube (CFST) stub columns subjected to sulfate corrosion and freeze-thaw cycle is examined by numerical investigation. The constitutive model of steel considered the Bauschinger effect, and compression (tension) damage coefficient was also adopt...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9101322/ https://www.ncbi.nlm.nih.gov/pubmed/35591432 http://dx.doi.org/10.3390/ma15093099 |
_version_ | 1784707057320984576 |
---|---|
author | Zhang, Tong Wen, Qianxin Gao, Lei Xu, Qian Tang, Jupeng |
author_facet | Zhang, Tong Wen, Qianxin Gao, Lei Xu, Qian Tang, Jupeng |
author_sort | Zhang, Tong |
collection | PubMed |
description | The hysteretic behavior of square concrete-filled steel tube (CFST) stub columns subjected to sulfate corrosion and freeze-thaw cycle is examined by numerical investigation. The constitutive model of steel considered the Bauschinger effect, and compression (tension) damage coefficient was also adopted for the constitutive model of core concrete. The experimental results are used to verify the finite element (FE) model, which could accurately predict the hysteretic behaviors of the CFST piers. Then, the effects of the yield strength of steel, compressive strength of concrete, steel ratio, axial compression ratio, and alternation time on ultimate horizontal load are evaluated by a parametric study. The results showed that the yield strength of steel and the steel ratio have a positive effect of hysteretic behavior. The compressive strength of concrete and alternation time significantly decreased the unloading stiffness which causes the pinching phenomenon. The yield strength of steel, compressive strength of concrete, and alternation time of environmental factors (corrosion-freeze-thaw cycles) has no obvious effect on the initial stiffness, while the steel ratio has a remarkable effect. The ultimate horizontal load increases with the increasing steel ratio, yield strength of steel and compressive strength of concrete. Meanwhile, the decrement of alternation time led to the increase of ultimate horizontal load. This suggests that the confinement coefficient and alternation time are the two main factors that impact the ultimate horizontal load. A formula which considers the reduction coefficient for the ultimate horizontal load of the CFST columns subjected to sulfate corrosion and freeze-thaw cycles is proposed. The formulae can accurately predict the ultimate horizontal load with mean value of 1.022 and standard deviation of 0.003. |
format | Online Article Text |
id | pubmed-9101322 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91013222022-05-14 Analytical Hysteretic Behavior of Square Concrete-Filled Steel Tube Pier Columns under Alternate Sulfate Corrosion and Freeze-Thaw Cycles Zhang, Tong Wen, Qianxin Gao, Lei Xu, Qian Tang, Jupeng Materials (Basel) Article The hysteretic behavior of square concrete-filled steel tube (CFST) stub columns subjected to sulfate corrosion and freeze-thaw cycle is examined by numerical investigation. The constitutive model of steel considered the Bauschinger effect, and compression (tension) damage coefficient was also adopted for the constitutive model of core concrete. The experimental results are used to verify the finite element (FE) model, which could accurately predict the hysteretic behaviors of the CFST piers. Then, the effects of the yield strength of steel, compressive strength of concrete, steel ratio, axial compression ratio, and alternation time on ultimate horizontal load are evaluated by a parametric study. The results showed that the yield strength of steel and the steel ratio have a positive effect of hysteretic behavior. The compressive strength of concrete and alternation time significantly decreased the unloading stiffness which causes the pinching phenomenon. The yield strength of steel, compressive strength of concrete, and alternation time of environmental factors (corrosion-freeze-thaw cycles) has no obvious effect on the initial stiffness, while the steel ratio has a remarkable effect. The ultimate horizontal load increases with the increasing steel ratio, yield strength of steel and compressive strength of concrete. Meanwhile, the decrement of alternation time led to the increase of ultimate horizontal load. This suggests that the confinement coefficient and alternation time are the two main factors that impact the ultimate horizontal load. A formula which considers the reduction coefficient for the ultimate horizontal load of the CFST columns subjected to sulfate corrosion and freeze-thaw cycles is proposed. The formulae can accurately predict the ultimate horizontal load with mean value of 1.022 and standard deviation of 0.003. MDPI 2022-04-25 /pmc/articles/PMC9101322/ /pubmed/35591432 http://dx.doi.org/10.3390/ma15093099 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhang, Tong Wen, Qianxin Gao, Lei Xu, Qian Tang, Jupeng Analytical Hysteretic Behavior of Square Concrete-Filled Steel Tube Pier Columns under Alternate Sulfate Corrosion and Freeze-Thaw Cycles |
title | Analytical Hysteretic Behavior of Square Concrete-Filled Steel Tube Pier Columns under Alternate Sulfate Corrosion and Freeze-Thaw Cycles |
title_full | Analytical Hysteretic Behavior of Square Concrete-Filled Steel Tube Pier Columns under Alternate Sulfate Corrosion and Freeze-Thaw Cycles |
title_fullStr | Analytical Hysteretic Behavior of Square Concrete-Filled Steel Tube Pier Columns under Alternate Sulfate Corrosion and Freeze-Thaw Cycles |
title_full_unstemmed | Analytical Hysteretic Behavior of Square Concrete-Filled Steel Tube Pier Columns under Alternate Sulfate Corrosion and Freeze-Thaw Cycles |
title_short | Analytical Hysteretic Behavior of Square Concrete-Filled Steel Tube Pier Columns under Alternate Sulfate Corrosion and Freeze-Thaw Cycles |
title_sort | analytical hysteretic behavior of square concrete-filled steel tube pier columns under alternate sulfate corrosion and freeze-thaw cycles |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9101322/ https://www.ncbi.nlm.nih.gov/pubmed/35591432 http://dx.doi.org/10.3390/ma15093099 |
work_keys_str_mv | AT zhangtong analyticalhystereticbehaviorofsquareconcretefilledsteeltubepiercolumnsunderalternatesulfatecorrosionandfreezethawcycles AT wenqianxin analyticalhystereticbehaviorofsquareconcretefilledsteeltubepiercolumnsunderalternatesulfatecorrosionandfreezethawcycles AT gaolei analyticalhystereticbehaviorofsquareconcretefilledsteeltubepiercolumnsunderalternatesulfatecorrosionandfreezethawcycles AT xuqian analyticalhystereticbehaviorofsquareconcretefilledsteeltubepiercolumnsunderalternatesulfatecorrosionandfreezethawcycles AT tangjupeng analyticalhystereticbehaviorofsquareconcretefilledsteeltubepiercolumnsunderalternatesulfatecorrosionandfreezethawcycles |