Cargando…

A Simple, Robust, and Convenient HPLC Assay for Urinary Lactulose and Mannitol in the Dual Sugar Absorption Test

Background: Heterogeneous laborious analytical methodologies for the determination of urinary lactulose and mannitol limit their utility in intestinal permeability testing. Methods: We developed an assay using a Shimadzu HPLC system, an Aminex HPX87C column, and refractive index detection. The test...

Descripción completa

Detalles Bibliográficos
Autores principales: Sequeira, Ivana R., Kruger, Marlena C., Hurst, Roger D., Lentle, Roger G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9101331/
https://www.ncbi.nlm.nih.gov/pubmed/35566024
http://dx.doi.org/10.3390/molecules27092677
_version_ 1784707059659309056
author Sequeira, Ivana R.
Kruger, Marlena C.
Hurst, Roger D.
Lentle, Roger G.
author_facet Sequeira, Ivana R.
Kruger, Marlena C.
Hurst, Roger D.
Lentle, Roger G.
author_sort Sequeira, Ivana R.
collection PubMed
description Background: Heterogeneous laborious analytical methodologies for the determination of urinary lactulose and mannitol limit their utility in intestinal permeability testing. Methods: We developed an assay using a Shimadzu HPLC system, an Aminex HPX87C column, and refractive index detection. The test was calibrated using a series of dilutions from standard stock solutions of lactulose and mannitol ‘spiked’ into urine samples. The utility to quantify urinary excretion during the dual sugar absorption test over 6 h was also determined. Results: Lactulose and mannitol were eluted isocratically at 5.7 and 10.1 min, respectively, with water as a mobile phase at a flow rate of 0.3 mL min(−1), 858 psi, 60 °C. The calibration curves for both sugars were linear up to 500 µg mL(−1) with a limit of detection in standard solutions at 4 µg mL(−1) and in ‘spiked’ urine samples at 15 µg mL(−1). The intra-assay and inter-assay CVs were between 2.0–5.1% and 2.0–5.1% for lactulose and 2.5–4.4% and 2.8–3.9% for mannitol. The urinary profiles of the 6 h absorption of lactulose and mannitol showed similar peak-retention times to standard solutions and were well-resolved at 5.9 and 10.4 min, respectively. Conclusions: The assay was easy to automate, using commonly available equipment and convenient requiring no prior laborious sample derivatization. The simplicity, reproducibility, and robustness of this assay facilitates its use in routine clinical settings for the quantification of intestinal permeability.
format Online
Article
Text
id pubmed-9101331
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91013312022-05-14 A Simple, Robust, and Convenient HPLC Assay for Urinary Lactulose and Mannitol in the Dual Sugar Absorption Test Sequeira, Ivana R. Kruger, Marlena C. Hurst, Roger D. Lentle, Roger G. Molecules Article Background: Heterogeneous laborious analytical methodologies for the determination of urinary lactulose and mannitol limit their utility in intestinal permeability testing. Methods: We developed an assay using a Shimadzu HPLC system, an Aminex HPX87C column, and refractive index detection. The test was calibrated using a series of dilutions from standard stock solutions of lactulose and mannitol ‘spiked’ into urine samples. The utility to quantify urinary excretion during the dual sugar absorption test over 6 h was also determined. Results: Lactulose and mannitol were eluted isocratically at 5.7 and 10.1 min, respectively, with water as a mobile phase at a flow rate of 0.3 mL min(−1), 858 psi, 60 °C. The calibration curves for both sugars were linear up to 500 µg mL(−1) with a limit of detection in standard solutions at 4 µg mL(−1) and in ‘spiked’ urine samples at 15 µg mL(−1). The intra-assay and inter-assay CVs were between 2.0–5.1% and 2.0–5.1% for lactulose and 2.5–4.4% and 2.8–3.9% for mannitol. The urinary profiles of the 6 h absorption of lactulose and mannitol showed similar peak-retention times to standard solutions and were well-resolved at 5.9 and 10.4 min, respectively. Conclusions: The assay was easy to automate, using commonly available equipment and convenient requiring no prior laborious sample derivatization. The simplicity, reproducibility, and robustness of this assay facilitates its use in routine clinical settings for the quantification of intestinal permeability. MDPI 2022-04-21 /pmc/articles/PMC9101331/ /pubmed/35566024 http://dx.doi.org/10.3390/molecules27092677 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sequeira, Ivana R.
Kruger, Marlena C.
Hurst, Roger D.
Lentle, Roger G.
A Simple, Robust, and Convenient HPLC Assay for Urinary Lactulose and Mannitol in the Dual Sugar Absorption Test
title A Simple, Robust, and Convenient HPLC Assay for Urinary Lactulose and Mannitol in the Dual Sugar Absorption Test
title_full A Simple, Robust, and Convenient HPLC Assay for Urinary Lactulose and Mannitol in the Dual Sugar Absorption Test
title_fullStr A Simple, Robust, and Convenient HPLC Assay for Urinary Lactulose and Mannitol in the Dual Sugar Absorption Test
title_full_unstemmed A Simple, Robust, and Convenient HPLC Assay for Urinary Lactulose and Mannitol in the Dual Sugar Absorption Test
title_short A Simple, Robust, and Convenient HPLC Assay for Urinary Lactulose and Mannitol in the Dual Sugar Absorption Test
title_sort simple, robust, and convenient hplc assay for urinary lactulose and mannitol in the dual sugar absorption test
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9101331/
https://www.ncbi.nlm.nih.gov/pubmed/35566024
http://dx.doi.org/10.3390/molecules27092677
work_keys_str_mv AT sequeiraivanar asimplerobustandconvenienthplcassayforurinarylactuloseandmannitolinthedualsugarabsorptiontest
AT krugermarlenac asimplerobustandconvenienthplcassayforurinarylactuloseandmannitolinthedualsugarabsorptiontest
AT hurstrogerd asimplerobustandconvenienthplcassayforurinarylactuloseandmannitolinthedualsugarabsorptiontest
AT lentlerogerg asimplerobustandconvenienthplcassayforurinarylactuloseandmannitolinthedualsugarabsorptiontest
AT sequeiraivanar simplerobustandconvenienthplcassayforurinarylactuloseandmannitolinthedualsugarabsorptiontest
AT krugermarlenac simplerobustandconvenienthplcassayforurinarylactuloseandmannitolinthedualsugarabsorptiontest
AT hurstrogerd simplerobustandconvenienthplcassayforurinarylactuloseandmannitolinthedualsugarabsorptiontest
AT lentlerogerg simplerobustandconvenienthplcassayforurinarylactuloseandmannitolinthedualsugarabsorptiontest