Cargando…
Determination of Chiral Impurity of Naproxen in Different Pharmaceutical Formulations Using Polysaccharide-Based Stationary Phases in Reversed-Phased Mode
A novel, validated, reversed-phase (RP), chiral high performance liquid chromatography (HPLC) method was developed for the enantiopurity control analysis of naproxen, a frequently used non-steroidal anti-inflammatory agent using polysaccharide-type chiral stationary phase (CSP). In the screening pha...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9101765/ https://www.ncbi.nlm.nih.gov/pubmed/35566336 http://dx.doi.org/10.3390/molecules27092986 |
_version_ | 1784707167339675648 |
---|---|
author | Papp, Lajos-Attila Krizbai, Sarolta Dobó, Máté Hancu, Gabriel Szabó, Zoltán-István Tóth, Gergő |
author_facet | Papp, Lajos-Attila Krizbai, Sarolta Dobó, Máté Hancu, Gabriel Szabó, Zoltán-István Tóth, Gergő |
author_sort | Papp, Lajos-Attila |
collection | PubMed |
description | A novel, validated, reversed-phase (RP), chiral high performance liquid chromatography (HPLC) method was developed for the enantiopurity control analysis of naproxen, a frequently used non-steroidal anti-inflammatory agent using polysaccharide-type chiral stationary phase (CSP). In the screening phase of method development, seven columns were tested in polar organic (PO) mode using mobile phases consisting of 0.1% acetic acid in methanol, ethanol, 2-propanol, and acetonitrile. Enantiorecognition was observed only in five cases. The best enantioseparation was observed on a Lux Amylose-1 column with 0.1% (v/v) acetic acid in ethanol with a resolution (R(s)) of 1.24. The enantiomer elution order was unfavorable, as the distomer eluted after the eutomer. When the ethanolic mobile phase was supplemented with water, enantiomer elution order reversal was observed, indicating a difference in the enantiorecognition mechanism upon switching from PO to RP mode. Furthermore, by changing ethanol to methanol, not only lower backpressure, but also higher resolution was obtained. Subsequent method optimization was performed using a face-centered central composite design (FCCD) to achieve higher chiral resolution in a shorter analysis time. Optimized parameters offering baseline separation were as follows: Lux Amylose-1 stationary phase, thermostated at 40 °C, and a mobile phase consisting of methanol:water:acetic acid 85:15:0.1 (v/v/v), delivered with 0.65 mL/min flow rate. Using these optimized parameters, a R(s) = 3.21 ± 0.03 was achieved within seven minutes. The optimized method was validated according to the ICH guidelines and successfully applied for the analysis of different pharmaceutical preparations, such as film-coated tablets and gel, as well as fixed-dose combination tablets, containing both naproxen and esomeprazole. |
format | Online Article Text |
id | pubmed-9101765 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91017652022-05-14 Determination of Chiral Impurity of Naproxen in Different Pharmaceutical Formulations Using Polysaccharide-Based Stationary Phases in Reversed-Phased Mode Papp, Lajos-Attila Krizbai, Sarolta Dobó, Máté Hancu, Gabriel Szabó, Zoltán-István Tóth, Gergő Molecules Article A novel, validated, reversed-phase (RP), chiral high performance liquid chromatography (HPLC) method was developed for the enantiopurity control analysis of naproxen, a frequently used non-steroidal anti-inflammatory agent using polysaccharide-type chiral stationary phase (CSP). In the screening phase of method development, seven columns were tested in polar organic (PO) mode using mobile phases consisting of 0.1% acetic acid in methanol, ethanol, 2-propanol, and acetonitrile. Enantiorecognition was observed only in five cases. The best enantioseparation was observed on a Lux Amylose-1 column with 0.1% (v/v) acetic acid in ethanol with a resolution (R(s)) of 1.24. The enantiomer elution order was unfavorable, as the distomer eluted after the eutomer. When the ethanolic mobile phase was supplemented with water, enantiomer elution order reversal was observed, indicating a difference in the enantiorecognition mechanism upon switching from PO to RP mode. Furthermore, by changing ethanol to methanol, not only lower backpressure, but also higher resolution was obtained. Subsequent method optimization was performed using a face-centered central composite design (FCCD) to achieve higher chiral resolution in a shorter analysis time. Optimized parameters offering baseline separation were as follows: Lux Amylose-1 stationary phase, thermostated at 40 °C, and a mobile phase consisting of methanol:water:acetic acid 85:15:0.1 (v/v/v), delivered with 0.65 mL/min flow rate. Using these optimized parameters, a R(s) = 3.21 ± 0.03 was achieved within seven minutes. The optimized method was validated according to the ICH guidelines and successfully applied for the analysis of different pharmaceutical preparations, such as film-coated tablets and gel, as well as fixed-dose combination tablets, containing both naproxen and esomeprazole. MDPI 2022-05-06 /pmc/articles/PMC9101765/ /pubmed/35566336 http://dx.doi.org/10.3390/molecules27092986 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Papp, Lajos-Attila Krizbai, Sarolta Dobó, Máté Hancu, Gabriel Szabó, Zoltán-István Tóth, Gergő Determination of Chiral Impurity of Naproxen in Different Pharmaceutical Formulations Using Polysaccharide-Based Stationary Phases in Reversed-Phased Mode |
title | Determination of Chiral Impurity of Naproxen in Different Pharmaceutical Formulations Using Polysaccharide-Based Stationary Phases in Reversed-Phased Mode |
title_full | Determination of Chiral Impurity of Naproxen in Different Pharmaceutical Formulations Using Polysaccharide-Based Stationary Phases in Reversed-Phased Mode |
title_fullStr | Determination of Chiral Impurity of Naproxen in Different Pharmaceutical Formulations Using Polysaccharide-Based Stationary Phases in Reversed-Phased Mode |
title_full_unstemmed | Determination of Chiral Impurity of Naproxen in Different Pharmaceutical Formulations Using Polysaccharide-Based Stationary Phases in Reversed-Phased Mode |
title_short | Determination of Chiral Impurity of Naproxen in Different Pharmaceutical Formulations Using Polysaccharide-Based Stationary Phases in Reversed-Phased Mode |
title_sort | determination of chiral impurity of naproxen in different pharmaceutical formulations using polysaccharide-based stationary phases in reversed-phased mode |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9101765/ https://www.ncbi.nlm.nih.gov/pubmed/35566336 http://dx.doi.org/10.3390/molecules27092986 |
work_keys_str_mv | AT papplajosattila determinationofchiralimpurityofnaproxenindifferentpharmaceuticalformulationsusingpolysaccharidebasedstationaryphasesinreversedphasedmode AT krizbaisarolta determinationofchiralimpurityofnaproxenindifferentpharmaceuticalformulationsusingpolysaccharidebasedstationaryphasesinreversedphasedmode AT dobomate determinationofchiralimpurityofnaproxenindifferentpharmaceuticalformulationsusingpolysaccharidebasedstationaryphasesinreversedphasedmode AT hancugabriel determinationofchiralimpurityofnaproxenindifferentpharmaceuticalformulationsusingpolysaccharidebasedstationaryphasesinreversedphasedmode AT szabozoltanistvan determinationofchiralimpurityofnaproxenindifferentpharmaceuticalformulationsusingpolysaccharidebasedstationaryphasesinreversedphasedmode AT tothgergo determinationofchiralimpurityofnaproxenindifferentpharmaceuticalformulationsusingpolysaccharidebasedstationaryphasesinreversedphasedmode |