Cargando…

Copper Cobalt Sulfide Structures Derived from MOF Precursors with Enhanced Electrochemical Glucose Sensing Properties

Nonenzymatic electrochemical detection of glucose is popular because of its low price, simple operation, high sensitivity, and good reproducibility. Co-Cu MOFs precursors were synthesized via the solvothermal way at first, and a series of porous spindle-like Cu-Co sulfide microparticles were obtaine...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Daojun, Zhang, Xiaobei, Bu, Yingping, Zhang, Jingchao, Zhang, Renchun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9102815/
https://www.ncbi.nlm.nih.gov/pubmed/35564103
http://dx.doi.org/10.3390/nano12091394
_version_ 1784707416809537536
author Zhang, Daojun
Zhang, Xiaobei
Bu, Yingping
Zhang, Jingchao
Zhang, Renchun
author_facet Zhang, Daojun
Zhang, Xiaobei
Bu, Yingping
Zhang, Jingchao
Zhang, Renchun
author_sort Zhang, Daojun
collection PubMed
description Nonenzymatic electrochemical detection of glucose is popular because of its low price, simple operation, high sensitivity, and good reproducibility. Co-Cu MOFs precursors were synthesized via the solvothermal way at first, and a series of porous spindle-like Cu-Co sulfide microparticles were obtained by secondary solvothermal sulfurization, which maintained the morphology of the MOFs precursors. Electrochemical studies exhibit that the as-synthesized Cu-Co sulfides own excellent nonenzymatic glucose detection performances. Compared with CuS, Co (II) ion-doped CuS can improve the conductivity and electrocatalytic activity of the materials. At a potential of 0.55 V, the as-prepared Co-CuS-2 modified electrode exhibits distinguished performance for glucose detection with wide linear ranges of 0.001–3.66 mM and high sensitivity of 1475.97 µA·mM(−1)·cm(−2), which was much higher than that of CuS- and Co-CuS-1-modified electrodes. The constructed sulfide sensors derived from MOF precursors exhibit a low detection limit and excellent anti-interference ability for glucose detection.
format Online
Article
Text
id pubmed-9102815
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91028152022-05-14 Copper Cobalt Sulfide Structures Derived from MOF Precursors with Enhanced Electrochemical Glucose Sensing Properties Zhang, Daojun Zhang, Xiaobei Bu, Yingping Zhang, Jingchao Zhang, Renchun Nanomaterials (Basel) Article Nonenzymatic electrochemical detection of glucose is popular because of its low price, simple operation, high sensitivity, and good reproducibility. Co-Cu MOFs precursors were synthesized via the solvothermal way at first, and a series of porous spindle-like Cu-Co sulfide microparticles were obtained by secondary solvothermal sulfurization, which maintained the morphology of the MOFs precursors. Electrochemical studies exhibit that the as-synthesized Cu-Co sulfides own excellent nonenzymatic glucose detection performances. Compared with CuS, Co (II) ion-doped CuS can improve the conductivity and electrocatalytic activity of the materials. At a potential of 0.55 V, the as-prepared Co-CuS-2 modified electrode exhibits distinguished performance for glucose detection with wide linear ranges of 0.001–3.66 mM and high sensitivity of 1475.97 µA·mM(−1)·cm(−2), which was much higher than that of CuS- and Co-CuS-1-modified electrodes. The constructed sulfide sensors derived from MOF precursors exhibit a low detection limit and excellent anti-interference ability for glucose detection. MDPI 2022-04-19 /pmc/articles/PMC9102815/ /pubmed/35564103 http://dx.doi.org/10.3390/nano12091394 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, Daojun
Zhang, Xiaobei
Bu, Yingping
Zhang, Jingchao
Zhang, Renchun
Copper Cobalt Sulfide Structures Derived from MOF Precursors with Enhanced Electrochemical Glucose Sensing Properties
title Copper Cobalt Sulfide Structures Derived from MOF Precursors with Enhanced Electrochemical Glucose Sensing Properties
title_full Copper Cobalt Sulfide Structures Derived from MOF Precursors with Enhanced Electrochemical Glucose Sensing Properties
title_fullStr Copper Cobalt Sulfide Structures Derived from MOF Precursors with Enhanced Electrochemical Glucose Sensing Properties
title_full_unstemmed Copper Cobalt Sulfide Structures Derived from MOF Precursors with Enhanced Electrochemical Glucose Sensing Properties
title_short Copper Cobalt Sulfide Structures Derived from MOF Precursors with Enhanced Electrochemical Glucose Sensing Properties
title_sort copper cobalt sulfide structures derived from mof precursors with enhanced electrochemical glucose sensing properties
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9102815/
https://www.ncbi.nlm.nih.gov/pubmed/35564103
http://dx.doi.org/10.3390/nano12091394
work_keys_str_mv AT zhangdaojun coppercobaltsulfidestructuresderivedfrommofprecursorswithenhancedelectrochemicalglucosesensingproperties
AT zhangxiaobei coppercobaltsulfidestructuresderivedfrommofprecursorswithenhancedelectrochemicalglucosesensingproperties
AT buyingping coppercobaltsulfidestructuresderivedfrommofprecursorswithenhancedelectrochemicalglucosesensingproperties
AT zhangjingchao coppercobaltsulfidestructuresderivedfrommofprecursorswithenhancedelectrochemicalglucosesensingproperties
AT zhangrenchun coppercobaltsulfidestructuresderivedfrommofprecursorswithenhancedelectrochemicalglucosesensingproperties