Cargando…

Instantaneous Gain in Video Head Impulse Test: A Reliability Study

OBJECTIVE: Vestibulo-ocular reflex gain at 40, 60, and 80 ms following the head movement start is calculated as the instantaneous gain. The purpose of this study was to investigate the reliability of instantaneous gain values at 40, 60, and 80 ms with testing and retesting in healthy adults. METHODS...

Descripción completa

Detalles Bibliográficos
Autores principales: Kabiş, Burak, Tutar, Hakan, Gündüz, Bülent, Aksoy, Songül
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9103567/
https://www.ncbi.nlm.nih.gov/pubmed/35634233
http://dx.doi.org/10.4274/tao.2022.2022-1-4
_version_ 1784707587334209536
author Kabiş, Burak
Tutar, Hakan
Gündüz, Bülent
Aksoy, Songül
author_facet Kabiş, Burak
Tutar, Hakan
Gündüz, Bülent
Aksoy, Songül
author_sort Kabiş, Burak
collection PubMed
description OBJECTIVE: Vestibulo-ocular reflex gain at 40, 60, and 80 ms following the head movement start is calculated as the instantaneous gain. The purpose of this study was to investigate the reliability of instantaneous gain values at 40, 60, and 80 ms with testing and retesting in healthy adults. METHODS: The study was conducted with Interacoustics EyeSeeCam vHIT (Interacoustics, Denmark), and 42 healthy adults were evaluated twice at half-hour intervals (test and retest) by the same practitioner. Agreement of mean gain, gain asymmetry, and instantaneous gain was evaluated using a paired samples t-test. RESULTS: Mean age of the participants was 33.62±11.17; 38.1% were male and 61.9% were female. In the degree of the agreement, paired sample correlation (r) between test and retest results of the horizontal semicircular canals was found to be higher than those of the vertical semicircular canals. Moreover, the highest correlation between test and retest for instantaneous gain, calculated for only horizontal semicircular canals, was found at 80 ms on each side (0.791; 0.838, right and left, respectively), while the lowest correlation between these parameters was found between the gain asymmetry values. CONCLUSION: The video head impulse test used in studies calculates the mean gain in approximately at 60 ms. However, the higher correlation between mean gain values at 80 ms in our findings indicates that gain calculation strategies and techniques for latencies should be discussed. Additionally, the low correlation of vertical semicircular canals for mean gain and gain asymmetry between semicircular canal pairs, which clearly shows that more standard and more reliable methods should be developed.
format Online
Article
Text
id pubmed-9103567
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-91035672022-05-26 Instantaneous Gain in Video Head Impulse Test: A Reliability Study Kabiş, Burak Tutar, Hakan Gündüz, Bülent Aksoy, Songül Turk Arch Otorhinolaryngol Original Investigation OBJECTIVE: Vestibulo-ocular reflex gain at 40, 60, and 80 ms following the head movement start is calculated as the instantaneous gain. The purpose of this study was to investigate the reliability of instantaneous gain values at 40, 60, and 80 ms with testing and retesting in healthy adults. METHODS: The study was conducted with Interacoustics EyeSeeCam vHIT (Interacoustics, Denmark), and 42 healthy adults were evaluated twice at half-hour intervals (test and retest) by the same practitioner. Agreement of mean gain, gain asymmetry, and instantaneous gain was evaluated using a paired samples t-test. RESULTS: Mean age of the participants was 33.62±11.17; 38.1% were male and 61.9% were female. In the degree of the agreement, paired sample correlation (r) between test and retest results of the horizontal semicircular canals was found to be higher than those of the vertical semicircular canals. Moreover, the highest correlation between test and retest for instantaneous gain, calculated for only horizontal semicircular canals, was found at 80 ms on each side (0.791; 0.838, right and left, respectively), while the lowest correlation between these parameters was found between the gain asymmetry values. CONCLUSION: The video head impulse test used in studies calculates the mean gain in approximately at 60 ms. However, the higher correlation between mean gain values at 80 ms in our findings indicates that gain calculation strategies and techniques for latencies should be discussed. Additionally, the low correlation of vertical semicircular canals for mean gain and gain asymmetry between semicircular canal pairs, which clearly shows that more standard and more reliable methods should be developed. Galenos Publishing 2022-03 2022-05-12 /pmc/articles/PMC9103567/ /pubmed/35634233 http://dx.doi.org/10.4274/tao.2022.2022-1-4 Text en ©Copyright 2022 by Official Journal of the Turkish Society of Otorhinolaryngology and Head and Neck Surgery https://creativecommons.org/licenses/by-nc/4.0/Content of this journal is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Original Investigation
Kabiş, Burak
Tutar, Hakan
Gündüz, Bülent
Aksoy, Songül
Instantaneous Gain in Video Head Impulse Test: A Reliability Study
title Instantaneous Gain in Video Head Impulse Test: A Reliability Study
title_full Instantaneous Gain in Video Head Impulse Test: A Reliability Study
title_fullStr Instantaneous Gain in Video Head Impulse Test: A Reliability Study
title_full_unstemmed Instantaneous Gain in Video Head Impulse Test: A Reliability Study
title_short Instantaneous Gain in Video Head Impulse Test: A Reliability Study
title_sort instantaneous gain in video head impulse test: a reliability study
topic Original Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9103567/
https://www.ncbi.nlm.nih.gov/pubmed/35634233
http://dx.doi.org/10.4274/tao.2022.2022-1-4
work_keys_str_mv AT kabisburak instantaneousgaininvideoheadimpulsetestareliabilitystudy
AT tutarhakan instantaneousgaininvideoheadimpulsetestareliabilitystudy
AT gunduzbulent instantaneousgaininvideoheadimpulsetestareliabilitystudy
AT aksoysongul instantaneousgaininvideoheadimpulsetestareliabilitystudy