Effect of Matrix Size Reduction on Textural Information in Clinical Magnetic Resonance Imaging
The selection of the matrix size is an important element of the magnetic resonance imaging (MRI) process, and has a significant impact on the acquired image quality. Signal to noise ratio, often used to assess MR image quality, has its limitations. Thus, for this purpose we propose a novel approach:...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9103884/ https://www.ncbi.nlm.nih.gov/pubmed/35566657 http://dx.doi.org/10.3390/jcm11092526 |
_version_ | 1784707659200462848 |
---|---|
author | Strzelecki, Michał Piórkowski, Adam Obuchowicz, Rafał |
author_facet | Strzelecki, Michał Piórkowski, Adam Obuchowicz, Rafał |
author_sort | Strzelecki, Michał |
collection | PubMed |
description | The selection of the matrix size is an important element of the magnetic resonance imaging (MRI) process, and has a significant impact on the acquired image quality. Signal to noise ratio, often used to assess MR image quality, has its limitations. Thus, for this purpose we propose a novel approach: the use of texture analysis as an index of the image quality that is sensitive for the change of matrix size. Image texture in biomedical images represents tissue and organ structures visualized via medical imaging modalities such as MRI. The correlation between texture parameters determined for the same tissues visualized in images acquired with different matrix sizes is analyzed to aid in the assessment of the selection of the optimal matrix size. T2-weighted coronal images of shoulders were acquired using five different matrix sizes while maintaining the same field of view; three regions of interest (bone, fat, and muscle) were considered. Lin’s correlation coefficients were calculated for all possible pairs of the 310-element texture feature vectors evaluated for each matrix. The obtained results are discussed considering the image noise and blurring effect visible in images acquired with smaller matrices. Taking these phenomena into account, recommendations for the selection of the matrix size used for the MRI imaging were proposed. |
format | Online Article Text |
id | pubmed-9103884 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91038842022-05-14 Effect of Matrix Size Reduction on Textural Information in Clinical Magnetic Resonance Imaging Strzelecki, Michał Piórkowski, Adam Obuchowicz, Rafał J Clin Med Technical Note The selection of the matrix size is an important element of the magnetic resonance imaging (MRI) process, and has a significant impact on the acquired image quality. Signal to noise ratio, often used to assess MR image quality, has its limitations. Thus, for this purpose we propose a novel approach: the use of texture analysis as an index of the image quality that is sensitive for the change of matrix size. Image texture in biomedical images represents tissue and organ structures visualized via medical imaging modalities such as MRI. The correlation between texture parameters determined for the same tissues visualized in images acquired with different matrix sizes is analyzed to aid in the assessment of the selection of the optimal matrix size. T2-weighted coronal images of shoulders were acquired using five different matrix sizes while maintaining the same field of view; three regions of interest (bone, fat, and muscle) were considered. Lin’s correlation coefficients were calculated for all possible pairs of the 310-element texture feature vectors evaluated for each matrix. The obtained results are discussed considering the image noise and blurring effect visible in images acquired with smaller matrices. Taking these phenomena into account, recommendations for the selection of the matrix size used for the MRI imaging were proposed. MDPI 2022-04-30 /pmc/articles/PMC9103884/ /pubmed/35566657 http://dx.doi.org/10.3390/jcm11092526 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Technical Note Strzelecki, Michał Piórkowski, Adam Obuchowicz, Rafał Effect of Matrix Size Reduction on Textural Information in Clinical Magnetic Resonance Imaging |
title | Effect of Matrix Size Reduction on Textural Information in Clinical Magnetic Resonance Imaging |
title_full | Effect of Matrix Size Reduction on Textural Information in Clinical Magnetic Resonance Imaging |
title_fullStr | Effect of Matrix Size Reduction on Textural Information in Clinical Magnetic Resonance Imaging |
title_full_unstemmed | Effect of Matrix Size Reduction on Textural Information in Clinical Magnetic Resonance Imaging |
title_short | Effect of Matrix Size Reduction on Textural Information in Clinical Magnetic Resonance Imaging |
title_sort | effect of matrix size reduction on textural information in clinical magnetic resonance imaging |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9103884/ https://www.ncbi.nlm.nih.gov/pubmed/35566657 http://dx.doi.org/10.3390/jcm11092526 |
work_keys_str_mv | AT strzeleckimichał effectofmatrixsizereductionontexturalinformationinclinicalmagneticresonanceimaging AT piorkowskiadam effectofmatrixsizereductionontexturalinformationinclinicalmagneticresonanceimaging AT obuchowiczrafał effectofmatrixsizereductionontexturalinformationinclinicalmagneticresonanceimaging |