Cargando…

Effect of Surface Tooling Techniques of Medical Titanium Implants on Bacterial Biofilm Formation In Vitro

The aim of this study was to assess the biofilm formation of Streptococcus mutans, Staphylococcus aureus, Enterococcus faecalis, and Escherichia coli on titanium implants with CAD-CAM tooling techniques. Twenty specimens of titanium were studied: Titanium grade 2 tooled with a Planmeca CAD-CAM milli...

Descripción completa

Detalles Bibliográficos
Autores principales: Sarfraz, Sonia, Mäntynen, Pilvi-helinä, Laurila, Marisa, Suojanen, Juho, Saarnio, Juha, Rossi, Sami, Horelli, Jani, Kaakinen, Mika, Leikola, Junnu, Reunanen, Justus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9103970/
https://www.ncbi.nlm.nih.gov/pubmed/35591562
http://dx.doi.org/10.3390/ma15093228
_version_ 1784707680561004544
author Sarfraz, Sonia
Mäntynen, Pilvi-helinä
Laurila, Marisa
Suojanen, Juho
Saarnio, Juha
Rossi, Sami
Horelli, Jani
Kaakinen, Mika
Leikola, Junnu
Reunanen, Justus
author_facet Sarfraz, Sonia
Mäntynen, Pilvi-helinä
Laurila, Marisa
Suojanen, Juho
Saarnio, Juha
Rossi, Sami
Horelli, Jani
Kaakinen, Mika
Leikola, Junnu
Reunanen, Justus
author_sort Sarfraz, Sonia
collection PubMed
description The aim of this study was to assess the biofilm formation of Streptococcus mutans, Staphylococcus aureus, Enterococcus faecalis, and Escherichia coli on titanium implants with CAD-CAM tooling techniques. Twenty specimens of titanium were studied: Titanium grade 2 tooled with a Planmeca CAD-CAM milling device (TiGrade 2), Ti(6)Al(4)V grade 5 as it comes from CAD-DMLS device (computer aided design-direct metal laser sintering device) (TiGrade 5), Ti(6)Al(4)V grade 23 as it comes from a CAD-CAM milling device (TiGrade 23), and CAD-DMLS TiGrade 5 polished with an abrasive disc (TiGrade 5 polished). Bacterial adhesion on the implants was completed with and without saliva treatment to mimic both extraoral and intraoral surgical methods of implant placement. Five specimens/implant types were used in the bacterial adhesion experiments. Autoclaved implant specimens were placed in petri plates and immersed in saliva solution for 30 min at room temperature and then washed 3× with 1× PBS. Bacterial suspensions of each strain were made and added to the specimens after saliva treatment. Biofilm was allowed to form for 24 h at 37 °C and the adhered bacteria was calculated. Tooling techniques had an insignificant effect on the bacterial adhesion by all the bacterial strains studied. However, there was a significant difference in biofilm formation between the saliva-treated and non-saliva-treated implants. Saliva contamination enhanced S. mutans, S. aureus, and E. faecalis adhesion in all material types studied. S. aureus was found to be the most adherent strain in the saliva-treated group, whereas E. coli was the most adherent strain in the non-saliva-treated group. In conclusion, CAD-CAM tooling techniques have little effect on bacterial adhesion. Saliva coating enhances the biofilm formation; therefore, saliva contamination of the implant must be minimized during implant placement. Further extensive studies are needed to evaluate the effects of surface treatments of the titanium implant on soft tissue response and to prevent the factors causing implant infection and failure.
format Online
Article
Text
id pubmed-9103970
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91039702022-05-14 Effect of Surface Tooling Techniques of Medical Titanium Implants on Bacterial Biofilm Formation In Vitro Sarfraz, Sonia Mäntynen, Pilvi-helinä Laurila, Marisa Suojanen, Juho Saarnio, Juha Rossi, Sami Horelli, Jani Kaakinen, Mika Leikola, Junnu Reunanen, Justus Materials (Basel) Article The aim of this study was to assess the biofilm formation of Streptococcus mutans, Staphylococcus aureus, Enterococcus faecalis, and Escherichia coli on titanium implants with CAD-CAM tooling techniques. Twenty specimens of titanium were studied: Titanium grade 2 tooled with a Planmeca CAD-CAM milling device (TiGrade 2), Ti(6)Al(4)V grade 5 as it comes from CAD-DMLS device (computer aided design-direct metal laser sintering device) (TiGrade 5), Ti(6)Al(4)V grade 23 as it comes from a CAD-CAM milling device (TiGrade 23), and CAD-DMLS TiGrade 5 polished with an abrasive disc (TiGrade 5 polished). Bacterial adhesion on the implants was completed with and without saliva treatment to mimic both extraoral and intraoral surgical methods of implant placement. Five specimens/implant types were used in the bacterial adhesion experiments. Autoclaved implant specimens were placed in petri plates and immersed in saliva solution for 30 min at room temperature and then washed 3× with 1× PBS. Bacterial suspensions of each strain were made and added to the specimens after saliva treatment. Biofilm was allowed to form for 24 h at 37 °C and the adhered bacteria was calculated. Tooling techniques had an insignificant effect on the bacterial adhesion by all the bacterial strains studied. However, there was a significant difference in biofilm formation between the saliva-treated and non-saliva-treated implants. Saliva contamination enhanced S. mutans, S. aureus, and E. faecalis adhesion in all material types studied. S. aureus was found to be the most adherent strain in the saliva-treated group, whereas E. coli was the most adherent strain in the non-saliva-treated group. In conclusion, CAD-CAM tooling techniques have little effect on bacterial adhesion. Saliva coating enhances the biofilm formation; therefore, saliva contamination of the implant must be minimized during implant placement. Further extensive studies are needed to evaluate the effects of surface treatments of the titanium implant on soft tissue response and to prevent the factors causing implant infection and failure. MDPI 2022-04-29 /pmc/articles/PMC9103970/ /pubmed/35591562 http://dx.doi.org/10.3390/ma15093228 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sarfraz, Sonia
Mäntynen, Pilvi-helinä
Laurila, Marisa
Suojanen, Juho
Saarnio, Juha
Rossi, Sami
Horelli, Jani
Kaakinen, Mika
Leikola, Junnu
Reunanen, Justus
Effect of Surface Tooling Techniques of Medical Titanium Implants on Bacterial Biofilm Formation In Vitro
title Effect of Surface Tooling Techniques of Medical Titanium Implants on Bacterial Biofilm Formation In Vitro
title_full Effect of Surface Tooling Techniques of Medical Titanium Implants on Bacterial Biofilm Formation In Vitro
title_fullStr Effect of Surface Tooling Techniques of Medical Titanium Implants on Bacterial Biofilm Formation In Vitro
title_full_unstemmed Effect of Surface Tooling Techniques of Medical Titanium Implants on Bacterial Biofilm Formation In Vitro
title_short Effect of Surface Tooling Techniques of Medical Titanium Implants on Bacterial Biofilm Formation In Vitro
title_sort effect of surface tooling techniques of medical titanium implants on bacterial biofilm formation in vitro
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9103970/
https://www.ncbi.nlm.nih.gov/pubmed/35591562
http://dx.doi.org/10.3390/ma15093228
work_keys_str_mv AT sarfrazsonia effectofsurfacetoolingtechniquesofmedicaltitaniumimplantsonbacterialbiofilmformationinvitro
AT mantynenpilvihelina effectofsurfacetoolingtechniquesofmedicaltitaniumimplantsonbacterialbiofilmformationinvitro
AT laurilamarisa effectofsurfacetoolingtechniquesofmedicaltitaniumimplantsonbacterialbiofilmformationinvitro
AT suojanenjuho effectofsurfacetoolingtechniquesofmedicaltitaniumimplantsonbacterialbiofilmformationinvitro
AT saarniojuha effectofsurfacetoolingtechniquesofmedicaltitaniumimplantsonbacterialbiofilmformationinvitro
AT rossisami effectofsurfacetoolingtechniquesofmedicaltitaniumimplantsonbacterialbiofilmformationinvitro
AT horellijani effectofsurfacetoolingtechniquesofmedicaltitaniumimplantsonbacterialbiofilmformationinvitro
AT kaakinenmika effectofsurfacetoolingtechniquesofmedicaltitaniumimplantsonbacterialbiofilmformationinvitro
AT leikolajunnu effectofsurfacetoolingtechniquesofmedicaltitaniumimplantsonbacterialbiofilmformationinvitro
AT reunanenjustus effectofsurfacetoolingtechniquesofmedicaltitaniumimplantsonbacterialbiofilmformationinvitro