Cargando…

Full Spectral Range Raman Signatures Related to Changes in Enameling Technologies from the 18th to the 20th Century: Guidelines, Effectiveness and Limitations of the Raman Analysis

This study investigates the comparison of the Raman signatures of different phases used in underglaze, inglaze and overglaze decors of selected European, Chinese and Japanese porcelains and enameled metalworks, which are particularly representative of technological developments in enameling. Specifi...

Descripción completa

Detalles Bibliográficos
Autor principal: Colomban, Philippe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9104039/
https://www.ncbi.nlm.nih.gov/pubmed/35591492
http://dx.doi.org/10.3390/ma15093158
_version_ 1784707697300471808
author Colomban, Philippe
author_facet Colomban, Philippe
author_sort Colomban, Philippe
collection PubMed
description This study investigates the comparison of the Raman signatures of different phases used in underglaze, inglaze and overglaze decors of selected European, Chinese and Japanese porcelains and enameled metalworks, which are particularly representative of technological developments in enameling. Specifically, the article deals with the main structural types or host networks (corundum/hematite, spinels, zircon, cassiterite, pyrochlore, apatite, sphene, etc.) used for colored enamels on porcelain, earthenware or metal rather than considering all types of pigments and opacifiers. According to the results, Raman microspectroscopy allows identifying of the fingerprint spectra of milestone technologies and represents a simple and rapid tool for detecting copies. Particular attention is paid to the information deduced from the examination of the associated ‘background’ and signatures from electronic transitions induced by uncontrolled traces or voluntary addition of rare earths (luminescence). The relationship between the grinding procedure and Raman signature is also discussed.
format Online
Article
Text
id pubmed-9104039
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91040392022-05-14 Full Spectral Range Raman Signatures Related to Changes in Enameling Technologies from the 18th to the 20th Century: Guidelines, Effectiveness and Limitations of the Raman Analysis Colomban, Philippe Materials (Basel) Article This study investigates the comparison of the Raman signatures of different phases used in underglaze, inglaze and overglaze decors of selected European, Chinese and Japanese porcelains and enameled metalworks, which are particularly representative of technological developments in enameling. Specifically, the article deals with the main structural types or host networks (corundum/hematite, spinels, zircon, cassiterite, pyrochlore, apatite, sphene, etc.) used for colored enamels on porcelain, earthenware or metal rather than considering all types of pigments and opacifiers. According to the results, Raman microspectroscopy allows identifying of the fingerprint spectra of milestone technologies and represents a simple and rapid tool for detecting copies. Particular attention is paid to the information deduced from the examination of the associated ‘background’ and signatures from electronic transitions induced by uncontrolled traces or voluntary addition of rare earths (luminescence). The relationship between the grinding procedure and Raman signature is also discussed. MDPI 2022-04-27 /pmc/articles/PMC9104039/ /pubmed/35591492 http://dx.doi.org/10.3390/ma15093158 Text en © 2022 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Colomban, Philippe
Full Spectral Range Raman Signatures Related to Changes in Enameling Technologies from the 18th to the 20th Century: Guidelines, Effectiveness and Limitations of the Raman Analysis
title Full Spectral Range Raman Signatures Related to Changes in Enameling Technologies from the 18th to the 20th Century: Guidelines, Effectiveness and Limitations of the Raman Analysis
title_full Full Spectral Range Raman Signatures Related to Changes in Enameling Technologies from the 18th to the 20th Century: Guidelines, Effectiveness and Limitations of the Raman Analysis
title_fullStr Full Spectral Range Raman Signatures Related to Changes in Enameling Technologies from the 18th to the 20th Century: Guidelines, Effectiveness and Limitations of the Raman Analysis
title_full_unstemmed Full Spectral Range Raman Signatures Related to Changes in Enameling Technologies from the 18th to the 20th Century: Guidelines, Effectiveness and Limitations of the Raman Analysis
title_short Full Spectral Range Raman Signatures Related to Changes in Enameling Technologies from the 18th to the 20th Century: Guidelines, Effectiveness and Limitations of the Raman Analysis
title_sort full spectral range raman signatures related to changes in enameling technologies from the 18th to the 20th century: guidelines, effectiveness and limitations of the raman analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9104039/
https://www.ncbi.nlm.nih.gov/pubmed/35591492
http://dx.doi.org/10.3390/ma15093158
work_keys_str_mv AT colombanphilippe fullspectralrangeramansignaturesrelatedtochangesinenamelingtechnologiesfromthe18thtothe20thcenturyguidelineseffectivenessandlimitationsoftheramananalysis