Standard Values and Concurrent Validity of a Newly Developed Occlusal Force-Measuring Device among Community-Dwelling Older Adults: The Otassha Study
Recently, an occlusal force-measuring device with a capacitive-type pressure-mapping sensor (OFMD-CPS) was developed. We aimed to establish age- and sex-specific standard values for OFMD-CPS-measured occlusal force (OF) and to assess the concurrent validity of the OFMD against another OF measuring s...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9104369/ https://www.ncbi.nlm.nih.gov/pubmed/35564983 http://dx.doi.org/10.3390/ijerph19095588 |
_version_ | 1784707777716813824 |
---|---|
author | Iwasaki, Masanori Maeda, Ichinosuke Kokubo, Yota Tanaka, Yoshitomo Ueno, Tetsuji Ohara, Yuki Motokawa, Keiko Hayakawa, Misato Shirobe, Maki Edahiro, Ayako Kawai, Hisashi Fujiwara, Yoshinori Ihara, Kazushige Kim, Hunkyung Watanabe, Yutaka Obuchi, Shuichi Hirano, Hirohiko |
author_facet | Iwasaki, Masanori Maeda, Ichinosuke Kokubo, Yota Tanaka, Yoshitomo Ueno, Tetsuji Ohara, Yuki Motokawa, Keiko Hayakawa, Misato Shirobe, Maki Edahiro, Ayako Kawai, Hisashi Fujiwara, Yoshinori Ihara, Kazushige Kim, Hunkyung Watanabe, Yutaka Obuchi, Shuichi Hirano, Hirohiko |
author_sort | Iwasaki, Masanori |
collection | PubMed |
description | Recently, an occlusal force-measuring device with a capacitive-type pressure-mapping sensor (OFMD-CPS) was developed. We aimed to establish age- and sex-specific standard values for OFMD-CPS-measured occlusal force (OF) and to assess the concurrent validity of the OFMD against another OF measuring system with a pressure-sensitive sheet (Dental Prescale II). Using data from a population-based study, we calculated the OFMD-CPS-measured OF means and deciles in 5-year age groups for each sex. The OFMD-CPS-measured OF was validated against the Dental Prescale II-measured OF with Spearman correlation coefficients. Furthermore, we calculated the area under the receiver operating characteristic curve (AUC) against the preexisting Dental Prescale II-measured OF cutoff value of 350 N. In total, 596 individuals (236 men and 360 women) with a mean (standard deviation (SD)) age of 73.7 (6.7) years were included in the analyses. The mean (SD) OFMD-CPS-measured OFs were 581.6 (284.6) N in men and 446.9 (209.9) N in women. There was a strong positive correlation (Spearman’s Rho = 0.73) between OFMD-CPS-measured and Dental Prescale II-measured OF. The diagnostic accuracy of the OFMD-CPS-measured OF for the Dental Prescale II-measured OF cutoff value was high (AUC = 0.88). In conclusion, we demonstrated standard values and concurrent validity of OFMD-CPS-measured OF in community-dwelling older adults. |
format | Online Article Text |
id | pubmed-9104369 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91043692022-05-14 Standard Values and Concurrent Validity of a Newly Developed Occlusal Force-Measuring Device among Community-Dwelling Older Adults: The Otassha Study Iwasaki, Masanori Maeda, Ichinosuke Kokubo, Yota Tanaka, Yoshitomo Ueno, Tetsuji Ohara, Yuki Motokawa, Keiko Hayakawa, Misato Shirobe, Maki Edahiro, Ayako Kawai, Hisashi Fujiwara, Yoshinori Ihara, Kazushige Kim, Hunkyung Watanabe, Yutaka Obuchi, Shuichi Hirano, Hirohiko Int J Environ Res Public Health Article Recently, an occlusal force-measuring device with a capacitive-type pressure-mapping sensor (OFMD-CPS) was developed. We aimed to establish age- and sex-specific standard values for OFMD-CPS-measured occlusal force (OF) and to assess the concurrent validity of the OFMD against another OF measuring system with a pressure-sensitive sheet (Dental Prescale II). Using data from a population-based study, we calculated the OFMD-CPS-measured OF means and deciles in 5-year age groups for each sex. The OFMD-CPS-measured OF was validated against the Dental Prescale II-measured OF with Spearman correlation coefficients. Furthermore, we calculated the area under the receiver operating characteristic curve (AUC) against the preexisting Dental Prescale II-measured OF cutoff value of 350 N. In total, 596 individuals (236 men and 360 women) with a mean (standard deviation (SD)) age of 73.7 (6.7) years were included in the analyses. The mean (SD) OFMD-CPS-measured OFs were 581.6 (284.6) N in men and 446.9 (209.9) N in women. There was a strong positive correlation (Spearman’s Rho = 0.73) between OFMD-CPS-measured and Dental Prescale II-measured OF. The diagnostic accuracy of the OFMD-CPS-measured OF for the Dental Prescale II-measured OF cutoff value was high (AUC = 0.88). In conclusion, we demonstrated standard values and concurrent validity of OFMD-CPS-measured OF in community-dwelling older adults. MDPI 2022-05-04 /pmc/articles/PMC9104369/ /pubmed/35564983 http://dx.doi.org/10.3390/ijerph19095588 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Iwasaki, Masanori Maeda, Ichinosuke Kokubo, Yota Tanaka, Yoshitomo Ueno, Tetsuji Ohara, Yuki Motokawa, Keiko Hayakawa, Misato Shirobe, Maki Edahiro, Ayako Kawai, Hisashi Fujiwara, Yoshinori Ihara, Kazushige Kim, Hunkyung Watanabe, Yutaka Obuchi, Shuichi Hirano, Hirohiko Standard Values and Concurrent Validity of a Newly Developed Occlusal Force-Measuring Device among Community-Dwelling Older Adults: The Otassha Study |
title | Standard Values and Concurrent Validity of a Newly Developed Occlusal Force-Measuring Device among Community-Dwelling Older Adults: The Otassha Study |
title_full | Standard Values and Concurrent Validity of a Newly Developed Occlusal Force-Measuring Device among Community-Dwelling Older Adults: The Otassha Study |
title_fullStr | Standard Values and Concurrent Validity of a Newly Developed Occlusal Force-Measuring Device among Community-Dwelling Older Adults: The Otassha Study |
title_full_unstemmed | Standard Values and Concurrent Validity of a Newly Developed Occlusal Force-Measuring Device among Community-Dwelling Older Adults: The Otassha Study |
title_short | Standard Values and Concurrent Validity of a Newly Developed Occlusal Force-Measuring Device among Community-Dwelling Older Adults: The Otassha Study |
title_sort | standard values and concurrent validity of a newly developed occlusal force-measuring device among community-dwelling older adults: the otassha study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9104369/ https://www.ncbi.nlm.nih.gov/pubmed/35564983 http://dx.doi.org/10.3390/ijerph19095588 |
work_keys_str_mv | AT iwasakimasanori standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT maedaichinosuke standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT kokuboyota standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT tanakayoshitomo standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT uenotetsuji standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT oharayuki standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT motokawakeiko standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT hayakawamisato standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT shirobemaki standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT edahiroayako standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT kawaihisashi standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT fujiwarayoshinori standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT iharakazushige standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT kimhunkyung standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT watanabeyutaka standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT obuchishuichi standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy AT hiranohirohiko standardvaluesandconcurrentvalidityofanewlydevelopedocclusalforcemeasuringdeviceamongcommunitydwellingolderadultstheotasshastudy |