Cargando…
Analysis of a Measurement Method and Test System for Pressure Change Rates in Commercial Vehicle Brake Chambers
The pressure change rate (PCR) of the brake chamber is the key control parameter and evaluation index in the pneumatic braking system for intelligent braking. The PCR threshold value of commercial vehicle brake chambers for braking comfort is analyzed. The PCR measurement method based on a laminar f...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9104896/ https://www.ncbi.nlm.nih.gov/pubmed/35591117 http://dx.doi.org/10.3390/s22093427 |
_version_ | 1784707906580512768 |
---|---|
author | Li, Gangyan Shen, Rui Liu, Yudong Yang, Fan Hu, Jian |
author_facet | Li, Gangyan Shen, Rui Liu, Yudong Yang, Fan Hu, Jian |
author_sort | Li, Gangyan |
collection | PubMed |
description | The pressure change rate (PCR) of the brake chamber is the key control parameter and evaluation index in the pneumatic braking system for intelligent braking. The PCR threshold value of commercial vehicle brake chambers for braking comfort is analyzed. The PCR measurement method based on a laminar flow resistance tube is proposed, and the PCR test system is designed. The simulation model of a PCR test system for commercial vehicle brake chambers is presented. By analyzing the simulation and experimental results, it is validated that the PCR test system of commercial vehicle brake chambers has the function of measuring PCR in real time. Finally, according to the MSA (Measurement System Analysis) evaluation method, the performance of the PCR test system for commercial vehicle brake chambers is analyzed, and the correctness and applicability of the test system are verified. |
format | Online Article Text |
id | pubmed-9104896 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91048962022-05-14 Analysis of a Measurement Method and Test System for Pressure Change Rates in Commercial Vehicle Brake Chambers Li, Gangyan Shen, Rui Liu, Yudong Yang, Fan Hu, Jian Sensors (Basel) Article The pressure change rate (PCR) of the brake chamber is the key control parameter and evaluation index in the pneumatic braking system for intelligent braking. The PCR threshold value of commercial vehicle brake chambers for braking comfort is analyzed. The PCR measurement method based on a laminar flow resistance tube is proposed, and the PCR test system is designed. The simulation model of a PCR test system for commercial vehicle brake chambers is presented. By analyzing the simulation and experimental results, it is validated that the PCR test system of commercial vehicle brake chambers has the function of measuring PCR in real time. Finally, according to the MSA (Measurement System Analysis) evaluation method, the performance of the PCR test system for commercial vehicle brake chambers is analyzed, and the correctness and applicability of the test system are verified. MDPI 2022-04-30 /pmc/articles/PMC9104896/ /pubmed/35591117 http://dx.doi.org/10.3390/s22093427 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Li, Gangyan Shen, Rui Liu, Yudong Yang, Fan Hu, Jian Analysis of a Measurement Method and Test System for Pressure Change Rates in Commercial Vehicle Brake Chambers |
title | Analysis of a Measurement Method and Test System for Pressure Change Rates in Commercial Vehicle Brake Chambers |
title_full | Analysis of a Measurement Method and Test System for Pressure Change Rates in Commercial Vehicle Brake Chambers |
title_fullStr | Analysis of a Measurement Method and Test System for Pressure Change Rates in Commercial Vehicle Brake Chambers |
title_full_unstemmed | Analysis of a Measurement Method and Test System for Pressure Change Rates in Commercial Vehicle Brake Chambers |
title_short | Analysis of a Measurement Method and Test System for Pressure Change Rates in Commercial Vehicle Brake Chambers |
title_sort | analysis of a measurement method and test system for pressure change rates in commercial vehicle brake chambers |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9104896/ https://www.ncbi.nlm.nih.gov/pubmed/35591117 http://dx.doi.org/10.3390/s22093427 |
work_keys_str_mv | AT ligangyan analysisofameasurementmethodandtestsystemforpressurechangeratesincommercialvehiclebrakechambers AT shenrui analysisofameasurementmethodandtestsystemforpressurechangeratesincommercialvehiclebrakechambers AT liuyudong analysisofameasurementmethodandtestsystemforpressurechangeratesincommercialvehiclebrakechambers AT yangfan analysisofameasurementmethodandtestsystemforpressurechangeratesincommercialvehiclebrakechambers AT hujian analysisofameasurementmethodandtestsystemforpressurechangeratesincommercialvehiclebrakechambers |