Determination of Buckling Behavior of Web-Stiffened Cold-Formed Steel Built-Up Column under Axial Compression

The practice of utilizing cold-drawn steel for structural and non-structural elements has expanded nowadays due to it being lighter in weight, economic section, desirable in fabrication, and its preferred post-buckling behavior over hot rolled sections. The cold-drawn steel section back to the back-...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohan, Muthuraman, Ramachandran, Anuradha, Amran, Mugahed, Borovkov, Aleksey
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9105070/
https://www.ncbi.nlm.nih.gov/pubmed/35591303
http://dx.doi.org/10.3390/ma15092968
_version_ 1784707950188691456
author Mohan, Muthuraman
Ramachandran, Anuradha
Amran, Mugahed
Borovkov, Aleksey
author_facet Mohan, Muthuraman
Ramachandran, Anuradha
Amran, Mugahed
Borovkov, Aleksey
author_sort Mohan, Muthuraman
collection PubMed
description The practice of utilizing cold-drawn steel for structural and non-structural elements has expanded nowadays due to it being lighter in weight, economic section, desirable in fabrication, and its preferred post-buckling behavior over hot rolled sections. The cold-drawn steel section back to the back-lipped channel section has a wide application as a structural member. The fasteners are provided at regular intervals for the long-span structure to prevent individual failures. This study is concerned with the inadequacy of research addressing the behavior of built-up columns. The relevant built-up column section is chosen based on the AISI-S100:2007 specification. Thirty-six specimens were designed and tested by varying web, flange, lip dimensions, spacing between the chords, and battened width experimentally subjected to an axial compression. Comparing 36 experimentally buckled specimens with the model generated by Finite Element Method accompanied with ASI-recommended two direct strength methods (DSMs). The DSM comprises the step-by-step procedure incorporated with the elastic, critical, and global distortional interaction. Based on the performed reliability analysis, such as the experimental, analytical, and theoretical studies, the failure load, buckling mode, the economic section, and design rules were proposed. Four suitable sections were selected from the proposal, and the validation study was carried out. From the validation study, experimental values were found to be 1.072 times the FEM values, and DSM values were found to be 0.97 times the FEM values. Based on the significant findings of this study, the proposed design recommendation and the corrected value for DSM are suitable for designing back-to-back stiffened columns.
format Online
Article
Text
id pubmed-9105070
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91050702022-05-14 Determination of Buckling Behavior of Web-Stiffened Cold-Formed Steel Built-Up Column under Axial Compression Mohan, Muthuraman Ramachandran, Anuradha Amran, Mugahed Borovkov, Aleksey Materials (Basel) Article The practice of utilizing cold-drawn steel for structural and non-structural elements has expanded nowadays due to it being lighter in weight, economic section, desirable in fabrication, and its preferred post-buckling behavior over hot rolled sections. The cold-drawn steel section back to the back-lipped channel section has a wide application as a structural member. The fasteners are provided at regular intervals for the long-span structure to prevent individual failures. This study is concerned with the inadequacy of research addressing the behavior of built-up columns. The relevant built-up column section is chosen based on the AISI-S100:2007 specification. Thirty-six specimens were designed and tested by varying web, flange, lip dimensions, spacing between the chords, and battened width experimentally subjected to an axial compression. Comparing 36 experimentally buckled specimens with the model generated by Finite Element Method accompanied with ASI-recommended two direct strength methods (DSMs). The DSM comprises the step-by-step procedure incorporated with the elastic, critical, and global distortional interaction. Based on the performed reliability analysis, such as the experimental, analytical, and theoretical studies, the failure load, buckling mode, the economic section, and design rules were proposed. Four suitable sections were selected from the proposal, and the validation study was carried out. From the validation study, experimental values were found to be 1.072 times the FEM values, and DSM values were found to be 0.97 times the FEM values. Based on the significant findings of this study, the proposed design recommendation and the corrected value for DSM are suitable for designing back-to-back stiffened columns. MDPI 2022-04-19 /pmc/articles/PMC9105070/ /pubmed/35591303 http://dx.doi.org/10.3390/ma15092968 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mohan, Muthuraman
Ramachandran, Anuradha
Amran, Mugahed
Borovkov, Aleksey
Determination of Buckling Behavior of Web-Stiffened Cold-Formed Steel Built-Up Column under Axial Compression
title Determination of Buckling Behavior of Web-Stiffened Cold-Formed Steel Built-Up Column under Axial Compression
title_full Determination of Buckling Behavior of Web-Stiffened Cold-Formed Steel Built-Up Column under Axial Compression
title_fullStr Determination of Buckling Behavior of Web-Stiffened Cold-Formed Steel Built-Up Column under Axial Compression
title_full_unstemmed Determination of Buckling Behavior of Web-Stiffened Cold-Formed Steel Built-Up Column under Axial Compression
title_short Determination of Buckling Behavior of Web-Stiffened Cold-Formed Steel Built-Up Column under Axial Compression
title_sort determination of buckling behavior of web-stiffened cold-formed steel built-up column under axial compression
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9105070/
https://www.ncbi.nlm.nih.gov/pubmed/35591303
http://dx.doi.org/10.3390/ma15092968
work_keys_str_mv AT mohanmuthuraman determinationofbucklingbehaviorofwebstiffenedcoldformedsteelbuiltupcolumnunderaxialcompression
AT ramachandrananuradha determinationofbucklingbehaviorofwebstiffenedcoldformedsteelbuiltupcolumnunderaxialcompression
AT amranmugahed determinationofbucklingbehaviorofwebstiffenedcoldformedsteelbuiltupcolumnunderaxialcompression
AT borovkovaleksey determinationofbucklingbehaviorofwebstiffenedcoldformedsteelbuiltupcolumnunderaxialcompression