Cargando…

Magnetic Reference Mark in a Linear Positioning System Generated by a Single Wiegand Pulse

A Wiegand sensor is composed of a strip of Wiegand wire and a pick-up coil. The research presented in this paper examines and characterizes the fast magnetization reversal in a Wiegand wire, which leads to changes in magnetic flux density in its pick-up coil to produce the so-called Wiegand pulse to...

Descripción completa

Detalles Bibliográficos
Autores principales: Lien, Hung-Lin, Chang, Jen-Yuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9105171/
https://www.ncbi.nlm.nih.gov/pubmed/35590875
http://dx.doi.org/10.3390/s22093185
_version_ 1784707974975979520
author Lien, Hung-Lin
Chang, Jen-Yuan
author_facet Lien, Hung-Lin
Chang, Jen-Yuan
author_sort Lien, Hung-Lin
collection PubMed
description A Wiegand sensor is composed of a strip of Wiegand wire and a pick-up coil. The research presented in this paper examines and characterizes the fast magnetization reversal in a Wiegand wire, which leads to changes in magnetic flux density in its pick-up coil to produce the so-called Wiegand pulse to be used as a reference mark in a linear positioning system. It was observed in this research that the magnitude and duration of the pulse voltage were independent of driving frequency, indicating that Wiegand effect sensors could be ideal for use as zero-speed transducers. The repeatability of the Wiegand pulse was found to vary with different magnetic flux intensities of external magnetic field, as well as the angle between the magnetic induction line and the Wiegand wire. Through calibrated experimental and numerical parametric studies, the mechanism for producing repeatable Wiegand pulses to be used as a reference mark for precision liner positioning systems was revealed, which represents the novelty of this research. On the basis of this mechanism, the optimal design combination of the Wiegand sensor’s position with respect to the magnetization source can be obtained. Utilizing commercially available Wiegand sensors, it was demonstrated in this research that with a Wiegand pulse serving as a magnetic reference mark, positioning repeatability of 0.3 um could be achieved, which is on the same order as optical scales. The work presented in this research has engineering implications as well as offering scientific insights into magnetization mechanisms for generating enough magnetic remanence to produce a Barkhausen jump, resulting in repeatable Wiegand for use as a reference mark in a linear positioning system.
format Online
Article
Text
id pubmed-9105171
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91051712022-05-14 Magnetic Reference Mark in a Linear Positioning System Generated by a Single Wiegand Pulse Lien, Hung-Lin Chang, Jen-Yuan Sensors (Basel) Article A Wiegand sensor is composed of a strip of Wiegand wire and a pick-up coil. The research presented in this paper examines and characterizes the fast magnetization reversal in a Wiegand wire, which leads to changes in magnetic flux density in its pick-up coil to produce the so-called Wiegand pulse to be used as a reference mark in a linear positioning system. It was observed in this research that the magnitude and duration of the pulse voltage were independent of driving frequency, indicating that Wiegand effect sensors could be ideal for use as zero-speed transducers. The repeatability of the Wiegand pulse was found to vary with different magnetic flux intensities of external magnetic field, as well as the angle between the magnetic induction line and the Wiegand wire. Through calibrated experimental and numerical parametric studies, the mechanism for producing repeatable Wiegand pulses to be used as a reference mark for precision liner positioning systems was revealed, which represents the novelty of this research. On the basis of this mechanism, the optimal design combination of the Wiegand sensor’s position with respect to the magnetization source can be obtained. Utilizing commercially available Wiegand sensors, it was demonstrated in this research that with a Wiegand pulse serving as a magnetic reference mark, positioning repeatability of 0.3 um could be achieved, which is on the same order as optical scales. The work presented in this research has engineering implications as well as offering scientific insights into magnetization mechanisms for generating enough magnetic remanence to produce a Barkhausen jump, resulting in repeatable Wiegand for use as a reference mark in a linear positioning system. MDPI 2022-04-21 /pmc/articles/PMC9105171/ /pubmed/35590875 http://dx.doi.org/10.3390/s22093185 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lien, Hung-Lin
Chang, Jen-Yuan
Magnetic Reference Mark in a Linear Positioning System Generated by a Single Wiegand Pulse
title Magnetic Reference Mark in a Linear Positioning System Generated by a Single Wiegand Pulse
title_full Magnetic Reference Mark in a Linear Positioning System Generated by a Single Wiegand Pulse
title_fullStr Magnetic Reference Mark in a Linear Positioning System Generated by a Single Wiegand Pulse
title_full_unstemmed Magnetic Reference Mark in a Linear Positioning System Generated by a Single Wiegand Pulse
title_short Magnetic Reference Mark in a Linear Positioning System Generated by a Single Wiegand Pulse
title_sort magnetic reference mark in a linear positioning system generated by a single wiegand pulse
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9105171/
https://www.ncbi.nlm.nih.gov/pubmed/35590875
http://dx.doi.org/10.3390/s22093185
work_keys_str_mv AT lienhunglin magneticreferencemarkinalinearpositioningsystemgeneratedbyasinglewiegandpulse
AT changjenyuan magneticreferencemarkinalinearpositioningsystemgeneratedbyasinglewiegandpulse