Method of Iterative Determination of the Polarized Area of Steel Reinforcement in Concrete Applied in the EIS Measurements

A new method is proposed for determining the test surface of steel rebar in concrete during polarization measurements of corrosion rate of reinforcement using the method of Electrochemical Impedance Spectroscopy. The methodology was based on the original 3D model of the steel-concrete system, in whi...

Descripción completa

Detalles Bibliográficos
Autor principal: Jaśniok, Mariusz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9105650/
https://www.ncbi.nlm.nih.gov/pubmed/35591614
http://dx.doi.org/10.3390/ma15093274
_version_ 1784708092224602112
author Jaśniok, Mariusz
author_facet Jaśniok, Mariusz
author_sort Jaśniok, Mariusz
collection PubMed
description A new method is proposed for determining the test surface of steel rebar in concrete during polarization measurements of corrosion rate of reinforcement using the method of Electrochemical Impedance Spectroscopy. The methodology was based on the original 3D model of the steel-concrete system, in which traditional equivalent electrical systems were coupled with factors that accounted for the complex geometry of the test reinforced concrete element. The developed method worked with a rectangular counter electrode without a guard ring assist, during an individual impedance measurement. The impact of the counter electrode size on the impedance spectra was verified in the first stage by tests conducted with ten types of counter electrodes. The obtained results in the form of empirical spectra were represented by theoretical spectra using the 3D model and the matching degrees were within a range of 0.96–1.73 at the expected level of 1.00. The obtained results in the form of spectra distribution were accurately represented by simulations with the 3D model. In the second stage, the iterative procedure for determining the polarization area of reinforcement in concrete was positively verified for additional test elements. Electrochemical parameters of the steel-concrete system were determined on the basis of the 3D model with a simultaneous adjustment of the polarization area on the rebar. In this case, the expected matching degree of 1.00 was obtained for each tested system after more than ten iterations starting from matching the model spectra to the empirical spectra at the level of 0.31–0.93.
format Online
Article
Text
id pubmed-9105650
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91056502022-05-14 Method of Iterative Determination of the Polarized Area of Steel Reinforcement in Concrete Applied in the EIS Measurements Jaśniok, Mariusz Materials (Basel) Article A new method is proposed for determining the test surface of steel rebar in concrete during polarization measurements of corrosion rate of reinforcement using the method of Electrochemical Impedance Spectroscopy. The methodology was based on the original 3D model of the steel-concrete system, in which traditional equivalent electrical systems were coupled with factors that accounted for the complex geometry of the test reinforced concrete element. The developed method worked with a rectangular counter electrode without a guard ring assist, during an individual impedance measurement. The impact of the counter electrode size on the impedance spectra was verified in the first stage by tests conducted with ten types of counter electrodes. The obtained results in the form of empirical spectra were represented by theoretical spectra using the 3D model and the matching degrees were within a range of 0.96–1.73 at the expected level of 1.00. The obtained results in the form of spectra distribution were accurately represented by simulations with the 3D model. In the second stage, the iterative procedure for determining the polarization area of reinforcement in concrete was positively verified for additional test elements. Electrochemical parameters of the steel-concrete system were determined on the basis of the 3D model with a simultaneous adjustment of the polarization area on the rebar. In this case, the expected matching degree of 1.00 was obtained for each tested system after more than ten iterations starting from matching the model spectra to the empirical spectra at the level of 0.31–0.93. MDPI 2022-05-03 /pmc/articles/PMC9105650/ /pubmed/35591614 http://dx.doi.org/10.3390/ma15093274 Text en © 2022 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jaśniok, Mariusz
Method of Iterative Determination of the Polarized Area of Steel Reinforcement in Concrete Applied in the EIS Measurements
title Method of Iterative Determination of the Polarized Area of Steel Reinforcement in Concrete Applied in the EIS Measurements
title_full Method of Iterative Determination of the Polarized Area of Steel Reinforcement in Concrete Applied in the EIS Measurements
title_fullStr Method of Iterative Determination of the Polarized Area of Steel Reinforcement in Concrete Applied in the EIS Measurements
title_full_unstemmed Method of Iterative Determination of the Polarized Area of Steel Reinforcement in Concrete Applied in the EIS Measurements
title_short Method of Iterative Determination of the Polarized Area of Steel Reinforcement in Concrete Applied in the EIS Measurements
title_sort method of iterative determination of the polarized area of steel reinforcement in concrete applied in the eis measurements
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9105650/
https://www.ncbi.nlm.nih.gov/pubmed/35591614
http://dx.doi.org/10.3390/ma15093274
work_keys_str_mv AT jasniokmariusz methodofiterativedeterminationofthepolarizedareaofsteelreinforcementinconcreteappliedintheeismeasurements