Cargando…

Peri-Implant Distal Radius Fracture: Proposal of a New Classification

A peri-implant fracture near the volar plate of the distal radius represents a rarity and can be associated with a mechanical failure of the devices. A literature review was conducted including all fractures that occurred around a volar wrist plate, which could be associated with an ulna fracture. A...

Descripción completa

Detalles Bibliográficos
Autores principales: Stramazzo, Leonardo, Rovere, Giuseppe, Cioffi, Alessio, Vigni, Giulio Edoardo, Galvano, Nicolò, D’Arienzo, Antonio, Letizia Mauro, Giulia, Camarda, Lawrence, D’Arienzo, Michele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9105785/
https://www.ncbi.nlm.nih.gov/pubmed/35566755
http://dx.doi.org/10.3390/jcm11092628
_version_ 1784708123952414720
author Stramazzo, Leonardo
Rovere, Giuseppe
Cioffi, Alessio
Vigni, Giulio Edoardo
Galvano, Nicolò
D’Arienzo, Antonio
Letizia Mauro, Giulia
Camarda, Lawrence
D’Arienzo, Michele
author_facet Stramazzo, Leonardo
Rovere, Giuseppe
Cioffi, Alessio
Vigni, Giulio Edoardo
Galvano, Nicolò
D’Arienzo, Antonio
Letizia Mauro, Giulia
Camarda, Lawrence
D’Arienzo, Michele
author_sort Stramazzo, Leonardo
collection PubMed
description A peri-implant fracture near the volar plate of the distal radius represents a rarity and can be associated with a mechanical failure of the devices. A literature review was conducted including all fractures that occurred around a volar wrist plate, which could be associated with an ulna fracture. All articles published until December 2021 were considered according to the guidelines presented in the PRISMA Statement. The search was conducted with the PubMed electronic database, Cochrane Database of Systematic Reviews, Medline, Embase, and Google Scholar. Only nine cases of these fractures were reported in the literature. The causes could be due to delayed union/non-union of the old fracture after low energy traumas, high energy trauma in patients with poor bone quality, or hardware mechanical failure. Furthermore, the literature review of peri-implant radius fracture shows different level of radius fracture and types of implant failure. In accordance with these different cases, a new classification of peri-implant fracture of the distal radius is proposed.
format Online
Article
Text
id pubmed-9105785
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91057852022-05-14 Peri-Implant Distal Radius Fracture: Proposal of a New Classification Stramazzo, Leonardo Rovere, Giuseppe Cioffi, Alessio Vigni, Giulio Edoardo Galvano, Nicolò D’Arienzo, Antonio Letizia Mauro, Giulia Camarda, Lawrence D’Arienzo, Michele J Clin Med Article A peri-implant fracture near the volar plate of the distal radius represents a rarity and can be associated with a mechanical failure of the devices. A literature review was conducted including all fractures that occurred around a volar wrist plate, which could be associated with an ulna fracture. All articles published until December 2021 were considered according to the guidelines presented in the PRISMA Statement. The search was conducted with the PubMed electronic database, Cochrane Database of Systematic Reviews, Medline, Embase, and Google Scholar. Only nine cases of these fractures were reported in the literature. The causes could be due to delayed union/non-union of the old fracture after low energy traumas, high energy trauma in patients with poor bone quality, or hardware mechanical failure. Furthermore, the literature review of peri-implant radius fracture shows different level of radius fracture and types of implant failure. In accordance with these different cases, a new classification of peri-implant fracture of the distal radius is proposed. MDPI 2022-05-07 /pmc/articles/PMC9105785/ /pubmed/35566755 http://dx.doi.org/10.3390/jcm11092628 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Stramazzo, Leonardo
Rovere, Giuseppe
Cioffi, Alessio
Vigni, Giulio Edoardo
Galvano, Nicolò
D’Arienzo, Antonio
Letizia Mauro, Giulia
Camarda, Lawrence
D’Arienzo, Michele
Peri-Implant Distal Radius Fracture: Proposal of a New Classification
title Peri-Implant Distal Radius Fracture: Proposal of a New Classification
title_full Peri-Implant Distal Radius Fracture: Proposal of a New Classification
title_fullStr Peri-Implant Distal Radius Fracture: Proposal of a New Classification
title_full_unstemmed Peri-Implant Distal Radius Fracture: Proposal of a New Classification
title_short Peri-Implant Distal Radius Fracture: Proposal of a New Classification
title_sort peri-implant distal radius fracture: proposal of a new classification
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9105785/
https://www.ncbi.nlm.nih.gov/pubmed/35566755
http://dx.doi.org/10.3390/jcm11092628
work_keys_str_mv AT stramazzoleonardo periimplantdistalradiusfractureproposalofanewclassification
AT roveregiuseppe periimplantdistalradiusfractureproposalofanewclassification
AT cioffialessio periimplantdistalradiusfractureproposalofanewclassification
AT vignigiulioedoardo periimplantdistalradiusfractureproposalofanewclassification
AT galvanonicolo periimplantdistalradiusfractureproposalofanewclassification
AT darienzoantonio periimplantdistalradiusfractureproposalofanewclassification
AT letiziamaurogiulia periimplantdistalradiusfractureproposalofanewclassification
AT camardalawrence periimplantdistalradiusfractureproposalofanewclassification
AT darienzomichele periimplantdistalradiusfractureproposalofanewclassification