Cargando…

Free-Breathing Phase-Resolved Oxygen-Enhanced Pulmonary MRI Based on 3D Stack-of-Stars UTE Sequence

Compared with hyperpolarized noble gas MRI, oxygen-enhanced lung imaging is a cost-effective approach to investigate lung function. In this study, we investigated the feasibility of free-breathing phase-resolved oxygen-enhanced pulmonary MRI based on a 3D stack-of-stars ultra-short echo time (UTE) s...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Pengfei, Zhang, Jichang, Nan, Zhen, Meersmann, Thomas, Wang, Chengbo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9105788/
https://www.ncbi.nlm.nih.gov/pubmed/35590959
http://dx.doi.org/10.3390/s22093270
_version_ 1784708124676980736
author Xu, Pengfei
Zhang, Jichang
Nan, Zhen
Meersmann, Thomas
Wang, Chengbo
author_facet Xu, Pengfei
Zhang, Jichang
Nan, Zhen
Meersmann, Thomas
Wang, Chengbo
author_sort Xu, Pengfei
collection PubMed
description Compared with hyperpolarized noble gas MRI, oxygen-enhanced lung imaging is a cost-effective approach to investigate lung function. In this study, we investigated the feasibility of free-breathing phase-resolved oxygen-enhanced pulmonary MRI based on a 3D stack-of-stars ultra-short echo time (UTE) sequence. We conducted both computer simulation and in vivo experiments and calculated percent signal enhancement maps of four different respiratory phases on four healthy volunteers from the end of expiration to the end of inspiration. The phantom experiment was implemented to verify simulation results. The respiratory phase was segmented based on the extracted respiratory signal and sliding window reconstruction, providing phase-resolved pulmonary MRI. Demons registration algorithm was applied to compensate for respiratory motion. The mean percent signal enhancement of the average phase increases from anterior to posterior region, matching previous literature. More details of pulmonary tissues were observed on post-oxygen inhalation images through the phase-resolved technique. Phase-resolved UTE pulmonary MRI shows the potential as a valuable method for oxygen-enhanced MRI that enables the investigation of lung ventilation on middle states of the respiratory cycle.
format Online
Article
Text
id pubmed-9105788
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91057882022-05-14 Free-Breathing Phase-Resolved Oxygen-Enhanced Pulmonary MRI Based on 3D Stack-of-Stars UTE Sequence Xu, Pengfei Zhang, Jichang Nan, Zhen Meersmann, Thomas Wang, Chengbo Sensors (Basel) Article Compared with hyperpolarized noble gas MRI, oxygen-enhanced lung imaging is a cost-effective approach to investigate lung function. In this study, we investigated the feasibility of free-breathing phase-resolved oxygen-enhanced pulmonary MRI based on a 3D stack-of-stars ultra-short echo time (UTE) sequence. We conducted both computer simulation and in vivo experiments and calculated percent signal enhancement maps of four different respiratory phases on four healthy volunteers from the end of expiration to the end of inspiration. The phantom experiment was implemented to verify simulation results. The respiratory phase was segmented based on the extracted respiratory signal and sliding window reconstruction, providing phase-resolved pulmonary MRI. Demons registration algorithm was applied to compensate for respiratory motion. The mean percent signal enhancement of the average phase increases from anterior to posterior region, matching previous literature. More details of pulmonary tissues were observed on post-oxygen inhalation images through the phase-resolved technique. Phase-resolved UTE pulmonary MRI shows the potential as a valuable method for oxygen-enhanced MRI that enables the investigation of lung ventilation on middle states of the respiratory cycle. MDPI 2022-04-24 /pmc/articles/PMC9105788/ /pubmed/35590959 http://dx.doi.org/10.3390/s22093270 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Xu, Pengfei
Zhang, Jichang
Nan, Zhen
Meersmann, Thomas
Wang, Chengbo
Free-Breathing Phase-Resolved Oxygen-Enhanced Pulmonary MRI Based on 3D Stack-of-Stars UTE Sequence
title Free-Breathing Phase-Resolved Oxygen-Enhanced Pulmonary MRI Based on 3D Stack-of-Stars UTE Sequence
title_full Free-Breathing Phase-Resolved Oxygen-Enhanced Pulmonary MRI Based on 3D Stack-of-Stars UTE Sequence
title_fullStr Free-Breathing Phase-Resolved Oxygen-Enhanced Pulmonary MRI Based on 3D Stack-of-Stars UTE Sequence
title_full_unstemmed Free-Breathing Phase-Resolved Oxygen-Enhanced Pulmonary MRI Based on 3D Stack-of-Stars UTE Sequence
title_short Free-Breathing Phase-Resolved Oxygen-Enhanced Pulmonary MRI Based on 3D Stack-of-Stars UTE Sequence
title_sort free-breathing phase-resolved oxygen-enhanced pulmonary mri based on 3d stack-of-stars ute sequence
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9105788/
https://www.ncbi.nlm.nih.gov/pubmed/35590959
http://dx.doi.org/10.3390/s22093270
work_keys_str_mv AT xupengfei freebreathingphaseresolvedoxygenenhancedpulmonarymribasedon3dstackofstarsutesequence
AT zhangjichang freebreathingphaseresolvedoxygenenhancedpulmonarymribasedon3dstackofstarsutesequence
AT nanzhen freebreathingphaseresolvedoxygenenhancedpulmonarymribasedon3dstackofstarsutesequence
AT meersmannthomas freebreathingphaseresolvedoxygenenhancedpulmonarymribasedon3dstackofstarsutesequence
AT wangchengbo freebreathingphaseresolvedoxygenenhancedpulmonarymribasedon3dstackofstarsutesequence