Cargando…
Development and validation of an ensemble artificial intelligence model for comprehensive imaging quality check to classify body parts and contrast enhancement
BACKGROUND: Despite the dramatic increase in the use of medical imaging in various therapeutic fields of clinical trials, the first step of image quality check (image QC), which aims to check whether images are uploaded appropriately according to the predefined rules, is still performed manually by...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9107169/ https://www.ncbi.nlm.nih.gov/pubmed/35562705 http://dx.doi.org/10.1186/s12880-022-00815-4 |
_version_ | 1784708431851028480 |
---|---|
author | Na, Seongwon Sung, Yu Sub Ko, Yousun Shin, Youngbin Lee, Junghyun Ha, Jiyeon Ham, Su Jung Yoon, Kyoungro Kim, Kyung Won |
author_facet | Na, Seongwon Sung, Yu Sub Ko, Yousun Shin, Youngbin Lee, Junghyun Ha, Jiyeon Ham, Su Jung Yoon, Kyoungro Kim, Kyung Won |
author_sort | Na, Seongwon |
collection | PubMed |
description | BACKGROUND: Despite the dramatic increase in the use of medical imaging in various therapeutic fields of clinical trials, the first step of image quality check (image QC), which aims to check whether images are uploaded appropriately according to the predefined rules, is still performed manually by image analysts, which requires a lot of manpower and time. METHODS: In this retrospective study, 1669 computed tomography (CT) images with five specific anatomical locations were collected from Asan Medical Center and Kangdong Sacred Heart Hospital. To generate the ground truth, two radiologists reviewed the anatomical locations and presence of contrast enhancement using the collected data. The individual deep learning model is developed through InceptionResNetv2 and transfer learning, and we propose Image Quality Check-Net (Image QC-Net), an ensemble AI model that utilizes it. To evaluate their clinical effectiveness, the overall accuracy and time spent on image quality check of a conventional model and ImageQC-net were compared. RESULTS: ImageQC-net body part classification showed excellent performance in both internal (precision, 100%; recall, 100% accuracy, 100%) and external verification sets (precision, 99.8%; recovery rate, 99.8%, accuracy, 99.8%). In addition, contrast enhancement classification performance achieved 100% precision, recall, and accuracy in the internal verification set and achieved (precision, 100%; recall, 100%; accuracy 100%) in the external dataset. In the case of clinical effects, the reduction of time by checking the quality of artificial intelligence (AI) support by analysts 1 and 2 (49.7% and 48.3%, respectively) was statistically significant (p < 0.001). CONCLUSIONS: Comprehensive AI techniques to identify body parts and contrast enhancement on CT images are highly accurate and can significantly reduce the time spent on image quality checks. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12880-022-00815-4. |
format | Online Article Text |
id | pubmed-9107169 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-91071692022-05-15 Development and validation of an ensemble artificial intelligence model for comprehensive imaging quality check to classify body parts and contrast enhancement Na, Seongwon Sung, Yu Sub Ko, Yousun Shin, Youngbin Lee, Junghyun Ha, Jiyeon Ham, Su Jung Yoon, Kyoungro Kim, Kyung Won BMC Med Imaging Research BACKGROUND: Despite the dramatic increase in the use of medical imaging in various therapeutic fields of clinical trials, the first step of image quality check (image QC), which aims to check whether images are uploaded appropriately according to the predefined rules, is still performed manually by image analysts, which requires a lot of manpower and time. METHODS: In this retrospective study, 1669 computed tomography (CT) images with five specific anatomical locations were collected from Asan Medical Center and Kangdong Sacred Heart Hospital. To generate the ground truth, two radiologists reviewed the anatomical locations and presence of contrast enhancement using the collected data. The individual deep learning model is developed through InceptionResNetv2 and transfer learning, and we propose Image Quality Check-Net (Image QC-Net), an ensemble AI model that utilizes it. To evaluate their clinical effectiveness, the overall accuracy and time spent on image quality check of a conventional model and ImageQC-net were compared. RESULTS: ImageQC-net body part classification showed excellent performance in both internal (precision, 100%; recall, 100% accuracy, 100%) and external verification sets (precision, 99.8%; recovery rate, 99.8%, accuracy, 99.8%). In addition, contrast enhancement classification performance achieved 100% precision, recall, and accuracy in the internal verification set and achieved (precision, 100%; recall, 100%; accuracy 100%) in the external dataset. In the case of clinical effects, the reduction of time by checking the quality of artificial intelligence (AI) support by analysts 1 and 2 (49.7% and 48.3%, respectively) was statistically significant (p < 0.001). CONCLUSIONS: Comprehensive AI techniques to identify body parts and contrast enhancement on CT images are highly accurate and can significantly reduce the time spent on image quality checks. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12880-022-00815-4. BioMed Central 2022-05-13 /pmc/articles/PMC9107169/ /pubmed/35562705 http://dx.doi.org/10.1186/s12880-022-00815-4 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Na, Seongwon Sung, Yu Sub Ko, Yousun Shin, Youngbin Lee, Junghyun Ha, Jiyeon Ham, Su Jung Yoon, Kyoungro Kim, Kyung Won Development and validation of an ensemble artificial intelligence model for comprehensive imaging quality check to classify body parts and contrast enhancement |
title | Development and validation of an ensemble artificial intelligence model for comprehensive imaging quality check to classify body parts and contrast enhancement |
title_full | Development and validation of an ensemble artificial intelligence model for comprehensive imaging quality check to classify body parts and contrast enhancement |
title_fullStr | Development and validation of an ensemble artificial intelligence model for comprehensive imaging quality check to classify body parts and contrast enhancement |
title_full_unstemmed | Development and validation of an ensemble artificial intelligence model for comprehensive imaging quality check to classify body parts and contrast enhancement |
title_short | Development and validation of an ensemble artificial intelligence model for comprehensive imaging quality check to classify body parts and contrast enhancement |
title_sort | development and validation of an ensemble artificial intelligence model for comprehensive imaging quality check to classify body parts and contrast enhancement |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9107169/ https://www.ncbi.nlm.nih.gov/pubmed/35562705 http://dx.doi.org/10.1186/s12880-022-00815-4 |
work_keys_str_mv | AT naseongwon developmentandvalidationofanensembleartificialintelligencemodelforcomprehensiveimagingqualitychecktoclassifybodypartsandcontrastenhancement AT sungyusub developmentandvalidationofanensembleartificialintelligencemodelforcomprehensiveimagingqualitychecktoclassifybodypartsandcontrastenhancement AT koyousun developmentandvalidationofanensembleartificialintelligencemodelforcomprehensiveimagingqualitychecktoclassifybodypartsandcontrastenhancement AT shinyoungbin developmentandvalidationofanensembleartificialintelligencemodelforcomprehensiveimagingqualitychecktoclassifybodypartsandcontrastenhancement AT leejunghyun developmentandvalidationofanensembleartificialintelligencemodelforcomprehensiveimagingqualitychecktoclassifybodypartsandcontrastenhancement AT hajiyeon developmentandvalidationofanensembleartificialintelligencemodelforcomprehensiveimagingqualitychecktoclassifybodypartsandcontrastenhancement AT hamsujung developmentandvalidationofanensembleartificialintelligencemodelforcomprehensiveimagingqualitychecktoclassifybodypartsandcontrastenhancement AT yoonkyoungro developmentandvalidationofanensembleartificialintelligencemodelforcomprehensiveimagingqualitychecktoclassifybodypartsandcontrastenhancement AT kimkyungwon developmentandvalidationofanensembleartificialintelligencemodelforcomprehensiveimagingqualitychecktoclassifybodypartsandcontrastenhancement |