Cargando…
Biomechanical study of oblique lumbar interbody fusion (OLIF) augmented with different types of instrumentation: a finite element analysis
BACKGROUND: To explore the biomechanical differences in oblique lumbar interbody fusion (OLIF) augmented by different types of instrumentation. METHODS: A three-dimensional nonlinear finite element (FE) model of an intact L3-S1 lumbar spine was built and validated. The intact model was modified to d...
Autores principales: | Cai, Xin-Yi, Bian, Han-Ming, Chen, Chao, Ma, Xin-Long, Yang, Qiang |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9107272/ https://www.ncbi.nlm.nih.gov/pubmed/35568923 http://dx.doi.org/10.1186/s13018-022-03143-z |
Ejemplares similares
-
Effects of osteoporosis on the biomechanics of various supplemental fixations co-applied with oblique lumbar interbody fusion (OLIF): a finite element analysis
por: Liu, Zi-Xuan, et al.
Publicado: (2022) -
Biomechanical effects of an oblique lumbar interbody fusion combined with posterior augmentation: a finite element analysis
por: Huang, Shengjia, et al.
Publicado: (2022) -
Neutral hip position for the oblique lumbar interbody fusion (OLIF) approach increases the retroperitoneal oblique corridor
por: Kotheeranurak, Vit, et al.
Publicado: (2020) -
Biomechanical study of two-level oblique lumbar interbody fusion with different types of lateral instrumentation: a finite element analysis
por: Zhong, Yuan, et al.
Publicado: (2023) -
Effect of Stand-Alone Oblique Lateral Interbody Fusion (OLIF) in Treating Lumbar Spine Lesions
por: Song, Yongxing, et al.
Publicado: (2023)