Collapsed endograft and lower limb ischemia from type B dissection repaired with thoracic endovascular aortic graft and iliac stenting: A case report and review of the literature
The collapse of an abdominal aortic endograft is a rare event. We present the case of a 60-year-old man with an abdominal endograft who came to the emergency department with chest, back, abdominal, and lower extremity pain in addition to a cool left foot. On imaging, he was found to have a type B ao...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9108323/ https://www.ncbi.nlm.nih.gov/pubmed/35586677 http://dx.doi.org/10.1016/j.jvscit.2022.02.010 |
_version_ | 1784708677079400448 |
---|---|
author | Cooke, Peter V. Bai, Halbert George, Justin M. Marin, Michael L. Tadros, Rami O. |
author_facet | Cooke, Peter V. Bai, Halbert George, Justin M. Marin, Michael L. Tadros, Rami O. |
author_sort | Cooke, Peter V. |
collection | PubMed |
description | The collapse of an abdominal aortic endograft is a rare event. We present the case of a 60-year-old man with an abdominal endograft who came to the emergency department with chest, back, abdominal, and lower extremity pain in addition to a cool left foot. On imaging, he was found to have a type B aortic dissection and a collapsed abdominal endograft. Subsequently, the patient was taken to the operating room and treated with a thoracic endovascular aortic repair, abdominal aortic cuff, and an iliac stent. Our study details this case and thoroughly reviews similar cases in the literature. |
format | Online Article Text |
id | pubmed-9108323 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-91083232022-05-17 Collapsed endograft and lower limb ischemia from type B dissection repaired with thoracic endovascular aortic graft and iliac stenting: A case report and review of the literature Cooke, Peter V. Bai, Halbert George, Justin M. Marin, Michael L. Tadros, Rami O. J Vasc Surg Cases Innov Tech Case report The collapse of an abdominal aortic endograft is a rare event. We present the case of a 60-year-old man with an abdominal endograft who came to the emergency department with chest, back, abdominal, and lower extremity pain in addition to a cool left foot. On imaging, he was found to have a type B aortic dissection and a collapsed abdominal endograft. Subsequently, the patient was taken to the operating room and treated with a thoracic endovascular aortic repair, abdominal aortic cuff, and an iliac stent. Our study details this case and thoroughly reviews similar cases in the literature. Elsevier 2022-03-09 /pmc/articles/PMC9108323/ /pubmed/35586677 http://dx.doi.org/10.1016/j.jvscit.2022.02.010 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Case report Cooke, Peter V. Bai, Halbert George, Justin M. Marin, Michael L. Tadros, Rami O. Collapsed endograft and lower limb ischemia from type B dissection repaired with thoracic endovascular aortic graft and iliac stenting: A case report and review of the literature |
title | Collapsed endograft and lower limb ischemia from type B dissection repaired with thoracic endovascular aortic graft and iliac stenting: A case report and review of the literature |
title_full | Collapsed endograft and lower limb ischemia from type B dissection repaired with thoracic endovascular aortic graft and iliac stenting: A case report and review of the literature |
title_fullStr | Collapsed endograft and lower limb ischemia from type B dissection repaired with thoracic endovascular aortic graft and iliac stenting: A case report and review of the literature |
title_full_unstemmed | Collapsed endograft and lower limb ischemia from type B dissection repaired with thoracic endovascular aortic graft and iliac stenting: A case report and review of the literature |
title_short | Collapsed endograft and lower limb ischemia from type B dissection repaired with thoracic endovascular aortic graft and iliac stenting: A case report and review of the literature |
title_sort | collapsed endograft and lower limb ischemia from type b dissection repaired with thoracic endovascular aortic graft and iliac stenting: a case report and review of the literature |
topic | Case report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9108323/ https://www.ncbi.nlm.nih.gov/pubmed/35586677 http://dx.doi.org/10.1016/j.jvscit.2022.02.010 |
work_keys_str_mv | AT cookepeterv collapsedendograftandlowerlimbischemiafromtypebdissectionrepairedwiththoracicendovascularaorticgraftandiliacstentingacasereportandreviewoftheliterature AT baihalbert collapsedendograftandlowerlimbischemiafromtypebdissectionrepairedwiththoracicendovascularaorticgraftandiliacstentingacasereportandreviewoftheliterature AT georgejustinm collapsedendograftandlowerlimbischemiafromtypebdissectionrepairedwiththoracicendovascularaorticgraftandiliacstentingacasereportandreviewoftheliterature AT marinmichaell collapsedendograftandlowerlimbischemiafromtypebdissectionrepairedwiththoracicendovascularaorticgraftandiliacstentingacasereportandreviewoftheliterature AT tadrosramio collapsedendograftandlowerlimbischemiafromtypebdissectionrepairedwiththoracicendovascularaorticgraftandiliacstentingacasereportandreviewoftheliterature |