Cargando…

Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study

AIM AND OBJECTIVE: This study was carried out to comparatively assess the efficiency of four methods of obturation viz Lentulo spiral, Navi tip syringe, Bi directional spiral, and Past inject carrier in deciduous teeth using vista scan. MATERIALS AND METHODS: A total sample of 100 primary root canal...

Descripción completa

Detalles Bibliográficos
Autores principales: Raju, Srikanth S, Reddy, Rajendra E, Rani, Thabitha S, Merum, Kiranmayi, Mudusu, Srujana P, Tulluru, Ajay M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9108824/
https://www.ncbi.nlm.nih.gov/pubmed/35645507
http://dx.doi.org/10.5005/jp-journals-10005-2132
_version_ 1784708789477310464
author Raju, Srikanth S
Reddy, Rajendra E
Rani, Thabitha S
Merum, Kiranmayi
Mudusu, Srujana P
Tulluru, Ajay M
author_facet Raju, Srikanth S
Reddy, Rajendra E
Rani, Thabitha S
Merum, Kiranmayi
Mudusu, Srujana P
Tulluru, Ajay M
author_sort Raju, Srikanth S
collection PubMed
description AIM AND OBJECTIVE: This study was carried out to comparatively assess the efficiency of four methods of obturation viz Lentulo spiral, Navi tip syringe, Bi directional spiral, and Past inject carrier in deciduous teeth using vista scan. MATERIALS AND METHODS: A total sample of 100 primary root canals [4 groups of 25 canals each] with 2/3(rd) of root length were selected and randomly allocated into four different obturating techniques, i.e., Group I: Lentulo spiral, Group II: Navi tip syringe, Group III: Bi directional spiral, and Group IV: Past inject carrier. The quality of obturation [Coll and sadrain, 1996] and presence or absence of voids were evaluated by using Vista scan. The recorded data was statistically analyzed. RESULTS: The highest mean rank value of optimally filled canals was obtained by Group IV [58.00] followed by Group I [50.00] with no significant difference. The highest mean rank value of under filled canals and over filled canals were obtained by Group III and Group II, respectively, and these results were statistically significant. All the four obturation techniques showed presence of voids with no significant difference. CONCLUSION: Both Lentulo spiral and Past inject carrier were equally efficient in attaining an optimally filled homogenous obturation in deciduous teeth. HOW TO CITE THIS ARTICLE: Raju SS, Reddy RE, Rani TS, et al. Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study. Int J Clin Pediatr Dent 2022;15(S-1):S52-S56.
format Online
Article
Text
id pubmed-9108824
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-91088242022-05-27 Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study Raju, Srikanth S Reddy, Rajendra E Rani, Thabitha S Merum, Kiranmayi Mudusu, Srujana P Tulluru, Ajay M Int J Clin Pediatr Dent Research Article AIM AND OBJECTIVE: This study was carried out to comparatively assess the efficiency of four methods of obturation viz Lentulo spiral, Navi tip syringe, Bi directional spiral, and Past inject carrier in deciduous teeth using vista scan. MATERIALS AND METHODS: A total sample of 100 primary root canals [4 groups of 25 canals each] with 2/3(rd) of root length were selected and randomly allocated into four different obturating techniques, i.e., Group I: Lentulo spiral, Group II: Navi tip syringe, Group III: Bi directional spiral, and Group IV: Past inject carrier. The quality of obturation [Coll and sadrain, 1996] and presence or absence of voids were evaluated by using Vista scan. The recorded data was statistically analyzed. RESULTS: The highest mean rank value of optimally filled canals was obtained by Group IV [58.00] followed by Group I [50.00] with no significant difference. The highest mean rank value of under filled canals and over filled canals were obtained by Group III and Group II, respectively, and these results were statistically significant. All the four obturation techniques showed presence of voids with no significant difference. CONCLUSION: Both Lentulo spiral and Past inject carrier were equally efficient in attaining an optimally filled homogenous obturation in deciduous teeth. HOW TO CITE THIS ARTICLE: Raju SS, Reddy RE, Rani TS, et al. Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study. Int J Clin Pediatr Dent 2022;15(S-1):S52-S56. Jaypee Brothers Medical Publishers 2022 /pmc/articles/PMC9108824/ /pubmed/35645507 http://dx.doi.org/10.5005/jp-journals-10005-2132 Text en Copyright © 2022; The Author(s). https://creativecommons.org/licenses/by-nc/4.0/© The Author(s). 2022 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Raju, Srikanth S
Reddy, Rajendra E
Rani, Thabitha S
Merum, Kiranmayi
Mudusu, Srujana P
Tulluru, Ajay M
Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study
title Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study
title_full Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study
title_fullStr Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study
title_full_unstemmed Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study
title_short Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study
title_sort assessment of four obturation methods in deciduous teeth using digital radiography: an in vivo study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9108824/
https://www.ncbi.nlm.nih.gov/pubmed/35645507
http://dx.doi.org/10.5005/jp-journals-10005-2132
work_keys_str_mv AT rajusrikanths assessmentoffourobturationmethodsindeciduousteethusingdigitalradiographyaninvivostudy
AT reddyrajendrae assessmentoffourobturationmethodsindeciduousteethusingdigitalradiographyaninvivostudy
AT ranithabithas assessmentoffourobturationmethodsindeciduousteethusingdigitalradiographyaninvivostudy
AT merumkiranmayi assessmentoffourobturationmethodsindeciduousteethusingdigitalradiographyaninvivostudy
AT mudususrujanap assessmentoffourobturationmethodsindeciduousteethusingdigitalradiographyaninvivostudy
AT tulluruajaym assessmentoffourobturationmethodsindeciduousteethusingdigitalradiographyaninvivostudy