Cargando…

Computed Tomographic Assessment of Remaining Dentin and Risk of Perforation after Kedo-S and Mtwo Rotary Instrumentation in Root Canals of Primary Teeth: An In Vitro Study

BACKGROUND: Root canal cleaning is a key step in the endodontic treatment of the primary molars. An innovative generation of endodontic instruments has been devised with the aim of emerging better procedures. The objective of the study is to assess the preparation of time, the risk of lateral perfor...

Descripción completa

Detalles Bibliográficos
Autores principales: Swaminathan, Kavitha, Rakkesh, Keerthana M, Haridoss, Selvakumar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9108826/
https://www.ncbi.nlm.nih.gov/pubmed/35645498
http://dx.doi.org/10.5005/jp-journals-10005-2217
_version_ 1784708789973286912
author Swaminathan, Kavitha
Rakkesh, Keerthana M
Haridoss, Selvakumar
author_facet Swaminathan, Kavitha
Rakkesh, Keerthana M
Haridoss, Selvakumar
author_sort Swaminathan, Kavitha
collection PubMed
description BACKGROUND: Root canal cleaning is a key step in the endodontic treatment of the primary molars. An innovative generation of endodontic instruments has been devised with the aim of emerging better procedures. The objective of the study is to assess the preparation of time, the risk of lateral perforation, and the removal of dentin from Kedo-S and Mtwo rotary instruments on primary teeth. STUDY DESIGN: This is an in vitro experimental study comparing the two groups. MATERIALS AND METHODS: A total of 50 extracted mandibular primary first molars are collected, divided randomly into two groups of 25 teeth each. Group I: Kedo-S Pediatric rotary file, Group II: Mtwo rotary file. Distal canal is standardized for evaluation and teeth are sectioned at the CEJ. The teeth were instrumented according to manufacturer's guideline. Both the groups are scanned before and after instrumentation of the canal using cone-beam computed tomography (CBCT) and values are evaluated. RESULTS: Compared with Mtwo files, Kedo-S files need less instrumentation time and limited lateral perforation. No statistical differences were reported between the instrumentation of Kedo-S and Mtwo with regard to the amount of dentin removed. CONCLUSION: In pediatric endodontics, Kedo-S pediatric rotary file can be considered an effective alternative to traditional rotary files because it requires less instrumentation time and preserves dentin thickness. HOW TO CITE THIS ARTICLE: Swaminathan K, Rakkesh KM, Haridoss S. Computed Tomographic Assessment of Remaining Dentin and Risk of Perforation after Kedo-S and Mtwo Rotary Instrumentation in Root Canals of Primary Teeth: An In Vitro Study. Int J Clin Pediatr Dent 2022;15(S-1):S87-S91.
format Online
Article
Text
id pubmed-9108826
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-91088262022-05-27 Computed Tomographic Assessment of Remaining Dentin and Risk of Perforation after Kedo-S and Mtwo Rotary Instrumentation in Root Canals of Primary Teeth: An In Vitro Study Swaminathan, Kavitha Rakkesh, Keerthana M Haridoss, Selvakumar Int J Clin Pediatr Dent Research Article BACKGROUND: Root canal cleaning is a key step in the endodontic treatment of the primary molars. An innovative generation of endodontic instruments has been devised with the aim of emerging better procedures. The objective of the study is to assess the preparation of time, the risk of lateral perforation, and the removal of dentin from Kedo-S and Mtwo rotary instruments on primary teeth. STUDY DESIGN: This is an in vitro experimental study comparing the two groups. MATERIALS AND METHODS: A total of 50 extracted mandibular primary first molars are collected, divided randomly into two groups of 25 teeth each. Group I: Kedo-S Pediatric rotary file, Group II: Mtwo rotary file. Distal canal is standardized for evaluation and teeth are sectioned at the CEJ. The teeth were instrumented according to manufacturer's guideline. Both the groups are scanned before and after instrumentation of the canal using cone-beam computed tomography (CBCT) and values are evaluated. RESULTS: Compared with Mtwo files, Kedo-S files need less instrumentation time and limited lateral perforation. No statistical differences were reported between the instrumentation of Kedo-S and Mtwo with regard to the amount of dentin removed. CONCLUSION: In pediatric endodontics, Kedo-S pediatric rotary file can be considered an effective alternative to traditional rotary files because it requires less instrumentation time and preserves dentin thickness. HOW TO CITE THIS ARTICLE: Swaminathan K, Rakkesh KM, Haridoss S. Computed Tomographic Assessment of Remaining Dentin and Risk of Perforation after Kedo-S and Mtwo Rotary Instrumentation in Root Canals of Primary Teeth: An In Vitro Study. Int J Clin Pediatr Dent 2022;15(S-1):S87-S91. Jaypee Brothers Medical Publishers 2022 /pmc/articles/PMC9108826/ /pubmed/35645498 http://dx.doi.org/10.5005/jp-journals-10005-2217 Text en Copyright © 2022; The Author(s). https://creativecommons.org/licenses/by-nc/4.0/© The Author(s). 2022 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Swaminathan, Kavitha
Rakkesh, Keerthana M
Haridoss, Selvakumar
Computed Tomographic Assessment of Remaining Dentin and Risk of Perforation after Kedo-S and Mtwo Rotary Instrumentation in Root Canals of Primary Teeth: An In Vitro Study
title Computed Tomographic Assessment of Remaining Dentin and Risk of Perforation after Kedo-S and Mtwo Rotary Instrumentation in Root Canals of Primary Teeth: An In Vitro Study
title_full Computed Tomographic Assessment of Remaining Dentin and Risk of Perforation after Kedo-S and Mtwo Rotary Instrumentation in Root Canals of Primary Teeth: An In Vitro Study
title_fullStr Computed Tomographic Assessment of Remaining Dentin and Risk of Perforation after Kedo-S and Mtwo Rotary Instrumentation in Root Canals of Primary Teeth: An In Vitro Study
title_full_unstemmed Computed Tomographic Assessment of Remaining Dentin and Risk of Perforation after Kedo-S and Mtwo Rotary Instrumentation in Root Canals of Primary Teeth: An In Vitro Study
title_short Computed Tomographic Assessment of Remaining Dentin and Risk of Perforation after Kedo-S and Mtwo Rotary Instrumentation in Root Canals of Primary Teeth: An In Vitro Study
title_sort computed tomographic assessment of remaining dentin and risk of perforation after kedo-s and mtwo rotary instrumentation in root canals of primary teeth: an in vitro study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9108826/
https://www.ncbi.nlm.nih.gov/pubmed/35645498
http://dx.doi.org/10.5005/jp-journals-10005-2217
work_keys_str_mv AT swaminathankavitha computedtomographicassessmentofremainingdentinandriskofperforationafterkedosandmtworotaryinstrumentationinrootcanalsofprimaryteethaninvitrostudy
AT rakkeshkeerthanam computedtomographicassessmentofremainingdentinandriskofperforationafterkedosandmtworotaryinstrumentationinrootcanalsofprimaryteethaninvitrostudy
AT haridossselvakumar computedtomographicassessmentofremainingdentinandriskofperforationafterkedosandmtworotaryinstrumentationinrootcanalsofprimaryteethaninvitrostudy