Cargando…
Biometric indicators of anterior segment parameters before and after laser peripheral iridotomy by swept-source optical coherent tomography
BACKGROUND: Primary angle closure glaucoma (PACG) is the most common type of glaucoma in China. Laser peripheral iridotomy (LPI) is the primary choice to treat PAC: We aim to evaluate the changes of biometric parameters of anterior segment and to find possible biometric predictors of the effect of l...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9109390/ https://www.ncbi.nlm.nih.gov/pubmed/35578256 http://dx.doi.org/10.1186/s12886-022-02448-1 |
_version_ | 1784708890398556160 |
---|---|
author | Yu, Bo Wang, Kang Zhang, Xiaomin Xing, Xiaoli |
author_facet | Yu, Bo Wang, Kang Zhang, Xiaomin Xing, Xiaoli |
author_sort | Yu, Bo |
collection | PubMed |
description | BACKGROUND: Primary angle closure glaucoma (PACG) is the most common type of glaucoma in China. Laser peripheral iridotomy (LPI) is the primary choice to treat PAC: We aim to evaluate the changes of biometric parameters of anterior segment and to find possible biometric predictors of the effect of laser peripheral iridotomy (LPI) in primary angle closure (PAC) eyes using swept-source optical coherent tomography (OCT). METHODS: LPI was performed in 52 PAC eyes of 28 participants. The change of intraocular pressure and anterior segment parameters, including angle opening distance (AOD500), AOD500 area, trabecular iris space area (TISA500), TISA500 volume, trabecular iris angle (TIA500), iridotrabecular contact (ITC) index, ITC area, anterior chamber volume (ACV), anterior chamber depth (ACD), lens vault (LV) and lens thickness (LT) before and 1 week after LPI were measured by Tomey CASIA2 anterior segment OCT. We also estimate and analyze potential associated factors possibly affecting the change of anterior chamber parameters. RESULTS: No post-laser complications were found. The ACD, LV and LT did not change significantly 1 week after LPI. AOD500, AOD500 area, TISA500, TISA500 volume, TIA500, ACV increased significantly after LPI. There was significant decrease in ITC index and ITC area. LT was positively correlated to the change of ITC index (β = 0.239, *p = 0.045). CONCLUSIONS: The anterior segment architecture significantly changed after LPI in PAC spectrum eyes. Crystalline lens measurements remained unchanged before and after LPI. AS-OCT can be used to follow anterior chamber parameter changes in PAC spectrum eyes. LT may play a role in the therapeutic effect of LPI. |
format | Online Article Text |
id | pubmed-9109390 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-91093902022-05-17 Biometric indicators of anterior segment parameters before and after laser peripheral iridotomy by swept-source optical coherent tomography Yu, Bo Wang, Kang Zhang, Xiaomin Xing, Xiaoli BMC Ophthalmol Research BACKGROUND: Primary angle closure glaucoma (PACG) is the most common type of glaucoma in China. Laser peripheral iridotomy (LPI) is the primary choice to treat PAC: We aim to evaluate the changes of biometric parameters of anterior segment and to find possible biometric predictors of the effect of laser peripheral iridotomy (LPI) in primary angle closure (PAC) eyes using swept-source optical coherent tomography (OCT). METHODS: LPI was performed in 52 PAC eyes of 28 participants. The change of intraocular pressure and anterior segment parameters, including angle opening distance (AOD500), AOD500 area, trabecular iris space area (TISA500), TISA500 volume, trabecular iris angle (TIA500), iridotrabecular contact (ITC) index, ITC area, anterior chamber volume (ACV), anterior chamber depth (ACD), lens vault (LV) and lens thickness (LT) before and 1 week after LPI were measured by Tomey CASIA2 anterior segment OCT. We also estimate and analyze potential associated factors possibly affecting the change of anterior chamber parameters. RESULTS: No post-laser complications were found. The ACD, LV and LT did not change significantly 1 week after LPI. AOD500, AOD500 area, TISA500, TISA500 volume, TIA500, ACV increased significantly after LPI. There was significant decrease in ITC index and ITC area. LT was positively correlated to the change of ITC index (β = 0.239, *p = 0.045). CONCLUSIONS: The anterior segment architecture significantly changed after LPI in PAC spectrum eyes. Crystalline lens measurements remained unchanged before and after LPI. AS-OCT can be used to follow anterior chamber parameter changes in PAC spectrum eyes. LT may play a role in the therapeutic effect of LPI. BioMed Central 2022-05-16 /pmc/articles/PMC9109390/ /pubmed/35578256 http://dx.doi.org/10.1186/s12886-022-02448-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Yu, Bo Wang, Kang Zhang, Xiaomin Xing, Xiaoli Biometric indicators of anterior segment parameters before and after laser peripheral iridotomy by swept-source optical coherent tomography |
title | Biometric indicators of anterior segment parameters before and after laser peripheral iridotomy by swept-source optical coherent tomography |
title_full | Biometric indicators of anterior segment parameters before and after laser peripheral iridotomy by swept-source optical coherent tomography |
title_fullStr | Biometric indicators of anterior segment parameters before and after laser peripheral iridotomy by swept-source optical coherent tomography |
title_full_unstemmed | Biometric indicators of anterior segment parameters before and after laser peripheral iridotomy by swept-source optical coherent tomography |
title_short | Biometric indicators of anterior segment parameters before and after laser peripheral iridotomy by swept-source optical coherent tomography |
title_sort | biometric indicators of anterior segment parameters before and after laser peripheral iridotomy by swept-source optical coherent tomography |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9109390/ https://www.ncbi.nlm.nih.gov/pubmed/35578256 http://dx.doi.org/10.1186/s12886-022-02448-1 |
work_keys_str_mv | AT yubo biometricindicatorsofanteriorsegmentparametersbeforeandafterlaserperipheraliridotomybysweptsourceopticalcoherenttomography AT wangkang biometricindicatorsofanteriorsegmentparametersbeforeandafterlaserperipheraliridotomybysweptsourceopticalcoherenttomography AT zhangxiaomin biometricindicatorsofanteriorsegmentparametersbeforeandafterlaserperipheraliridotomybysweptsourceopticalcoherenttomography AT xingxiaoli biometricindicatorsofanteriorsegmentparametersbeforeandafterlaserperipheraliridotomybysweptsourceopticalcoherenttomography |