Cargando…
Comparison of Accuracy and Clinical Outcomes of Robot-Assisted Versus Fluoroscopy-Guided Pedicle Screw Placement in Posterior Cervical Surgery
STUDY DESIGN: This was a prospective controlled study. OBJECTIVE: To compare the accuracy and clinical outcomes of robot-assisted (RA) and fluoroscopy-guided (FG) pedicle screw placement in posterior cervical surgery. METHODS: This study included 58 patients. The primary outcome measures were the 1-...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9109572/ https://www.ncbi.nlm.nih.gov/pubmed/32975454 http://dx.doi.org/10.1177/2192568220960406 |
_version_ | 1784708920289263616 |
---|---|
author | Su, Xin-Jin Lv, Zhen-Dong Chen, Zhi Wang, Kun Zhu, Chao Chen, Hao Han, Ying-Chao Song, Qing-Xin Lao, Li-Feng Zhang, Yu-Hui Li, Quan Shen, Hong-Xing |
author_facet | Su, Xin-Jin Lv, Zhen-Dong Chen, Zhi Wang, Kun Zhu, Chao Chen, Hao Han, Ying-Chao Song, Qing-Xin Lao, Li-Feng Zhang, Yu-Hui Li, Quan Shen, Hong-Xing |
author_sort | Su, Xin-Jin |
collection | PubMed |
description | STUDY DESIGN: This was a prospective controlled study. OBJECTIVE: To compare the accuracy and clinical outcomes of robot-assisted (RA) and fluoroscopy-guided (FG) pedicle screw placement in posterior cervical surgery. METHODS: This study included 58 patients. The primary outcome measures were the 1-time success rate and the accuracy of pedicle screw placement according to the Gertzbein-Robbins scales. The secondary outcome measures, including the operative time, intraoperative blood loss, hospital stay, cumulative radiation time, radiation dose, intraoperative advent events, and postoperative complications, were recorded and analyzed. The Japanese Orthopedics Association (JOA) scores and Neck Disability Index (NDI) were used to assess the neurological function of patients before and at 3 and 6 months after surgery. RESULTS: The rate of grade A was significantly higher in the RA group than in the FG group (90.6% and 71.1%; P < .001). The clinically acceptable accuracy was 97.2% in the RA group and 90.7% in the FG group (P = .009). Moreover, the 1-time success rate was significantly higher in the RA group than in the FG group. The RA group had less radiation time (P < .001) and less radiation dose (P = .002) but longer operative time (P = .001). There were no significant differences in terms of intraoperative blood loss, hospital stay, intraoperative adverse events, postoperative complications, JOA scores, and NDI scores at each follow-up time point between the 2 groups. CONCLUSIONS: The RA technique achieved higher accuracy and 1-time success rate of pedicle screw placement in posterior cervical surgery while achieving comparable clinical outcomes. |
format | Online Article Text |
id | pubmed-9109572 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-91095722022-05-17 Comparison of Accuracy and Clinical Outcomes of Robot-Assisted Versus Fluoroscopy-Guided Pedicle Screw Placement in Posterior Cervical Surgery Su, Xin-Jin Lv, Zhen-Dong Chen, Zhi Wang, Kun Zhu, Chao Chen, Hao Han, Ying-Chao Song, Qing-Xin Lao, Li-Feng Zhang, Yu-Hui Li, Quan Shen, Hong-Xing Global Spine J Original Articles STUDY DESIGN: This was a prospective controlled study. OBJECTIVE: To compare the accuracy and clinical outcomes of robot-assisted (RA) and fluoroscopy-guided (FG) pedicle screw placement in posterior cervical surgery. METHODS: This study included 58 patients. The primary outcome measures were the 1-time success rate and the accuracy of pedicle screw placement according to the Gertzbein-Robbins scales. The secondary outcome measures, including the operative time, intraoperative blood loss, hospital stay, cumulative radiation time, radiation dose, intraoperative advent events, and postoperative complications, were recorded and analyzed. The Japanese Orthopedics Association (JOA) scores and Neck Disability Index (NDI) were used to assess the neurological function of patients before and at 3 and 6 months after surgery. RESULTS: The rate of grade A was significantly higher in the RA group than in the FG group (90.6% and 71.1%; P < .001). The clinically acceptable accuracy was 97.2% in the RA group and 90.7% in the FG group (P = .009). Moreover, the 1-time success rate was significantly higher in the RA group than in the FG group. The RA group had less radiation time (P < .001) and less radiation dose (P = .002) but longer operative time (P = .001). There were no significant differences in terms of intraoperative blood loss, hospital stay, intraoperative adverse events, postoperative complications, JOA scores, and NDI scores at each follow-up time point between the 2 groups. CONCLUSIONS: The RA technique achieved higher accuracy and 1-time success rate of pedicle screw placement in posterior cervical surgery while achieving comparable clinical outcomes. SAGE Publications 2020-09-25 2022-05 /pmc/articles/PMC9109572/ /pubmed/32975454 http://dx.doi.org/10.1177/2192568220960406 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Articles Su, Xin-Jin Lv, Zhen-Dong Chen, Zhi Wang, Kun Zhu, Chao Chen, Hao Han, Ying-Chao Song, Qing-Xin Lao, Li-Feng Zhang, Yu-Hui Li, Quan Shen, Hong-Xing Comparison of Accuracy and Clinical Outcomes of Robot-Assisted Versus Fluoroscopy-Guided Pedicle Screw Placement in Posterior Cervical Surgery |
title | Comparison of Accuracy and Clinical Outcomes of Robot-Assisted Versus
Fluoroscopy-Guided Pedicle Screw Placement in Posterior Cervical
Surgery |
title_full | Comparison of Accuracy and Clinical Outcomes of Robot-Assisted Versus
Fluoroscopy-Guided Pedicle Screw Placement in Posterior Cervical
Surgery |
title_fullStr | Comparison of Accuracy and Clinical Outcomes of Robot-Assisted Versus
Fluoroscopy-Guided Pedicle Screw Placement in Posterior Cervical
Surgery |
title_full_unstemmed | Comparison of Accuracy and Clinical Outcomes of Robot-Assisted Versus
Fluoroscopy-Guided Pedicle Screw Placement in Posterior Cervical
Surgery |
title_short | Comparison of Accuracy and Clinical Outcomes of Robot-Assisted Versus
Fluoroscopy-Guided Pedicle Screw Placement in Posterior Cervical
Surgery |
title_sort | comparison of accuracy and clinical outcomes of robot-assisted versus
fluoroscopy-guided pedicle screw placement in posterior cervical
surgery |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9109572/ https://www.ncbi.nlm.nih.gov/pubmed/32975454 http://dx.doi.org/10.1177/2192568220960406 |
work_keys_str_mv | AT suxinjin comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery AT lvzhendong comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery AT chenzhi comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery AT wangkun comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery AT zhuchao comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery AT chenhao comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery AT hanyingchao comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery AT songqingxin comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery AT laolifeng comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery AT zhangyuhui comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery AT liquan comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery AT shenhongxing comparisonofaccuracyandclinicaloutcomesofrobotassistedversusfluoroscopyguidedpediclescrewplacementinposteriorcervicalsurgery |