Cargando…

Reliability of Electric Pulp Test, Cold Pulp Test or Tooth Transillumination to Assess Pulpal Health in Permanent Dog Teeth

The aim of this study was to evaluate the reliability of electric pulp test (EPT), cold pulp test (CPT) and tooth transillumination (TTI) in the assessment of pulpal health in dog teeth. Forty-five client-owned dogs requiring tooth extraction or pulpectomy were included. For each patient, one affect...

Descripción completa

Detalles Bibliográficos
Autores principales: Proulx, Caroline, Dumais, Yvan, Beauchamp, Guy, Steagall, Paulo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9109579/
https://www.ncbi.nlm.nih.gov/pubmed/35257623
http://dx.doi.org/10.1177/08987564221076363
_version_ 1784708921980616704
author Proulx, Caroline
Dumais, Yvan
Beauchamp, Guy
Steagall, Paulo
author_facet Proulx, Caroline
Dumais, Yvan
Beauchamp, Guy
Steagall, Paulo
author_sort Proulx, Caroline
collection PubMed
description The aim of this study was to evaluate the reliability of electric pulp test (EPT), cold pulp test (CPT) and tooth transillumination (TTI) in the assessment of pulpal health in dog teeth. Forty-five client-owned dogs requiring tooth extraction or pulpectomy were included. For each patient, one affected and two control healthy teeth were evaluated with EPT, followed by CPT and TTI. Direct pulp inspection was used as a gold standard. The real pulpal health (vital or necrotic) was determined by the presence or absence of bleeding after creating access to the pulp chamber. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of EPT, CPT and TTI were obtained for each pulp test using the binomial Clopper-Pearson exact method to establish confidence intervals. Forty-five affected teeth were tested. Forty-three were tested with EPT, CPT, and TTI, and two were tested solely with EPT and CPT. All dogs tested with EPT and TTI were included in the study whereas 21 out of 45 (47%) dogs tested with CPT were excluded. The sensitivity, specificity, PPV, NPV and accuracy were respectively 0.96, 1.00, 1.00, 0.96 and 0.98 for EPT; 1.00, 0.89, 0.92, 1.00 and 0.95 for CPT; and 0.59, 0.95, 0.94, 0.67 and 0.76 for TTI. This study concluded that EPT is a highly reliable diagnostic test to evaluate pulpal health in dogs. The high accuracy of CPT is conditional on the patient's responsiveness to stimulation applied to its control healthy teeth. TTI was the least reliable test in the study.
format Online
Article
Text
id pubmed-9109579
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-91095792022-05-17 Reliability of Electric Pulp Test, Cold Pulp Test or Tooth Transillumination to Assess Pulpal Health in Permanent Dog Teeth Proulx, Caroline Dumais, Yvan Beauchamp, Guy Steagall, Paulo J Vet Dent Original Studies The aim of this study was to evaluate the reliability of electric pulp test (EPT), cold pulp test (CPT) and tooth transillumination (TTI) in the assessment of pulpal health in dog teeth. Forty-five client-owned dogs requiring tooth extraction or pulpectomy were included. For each patient, one affected and two control healthy teeth were evaluated with EPT, followed by CPT and TTI. Direct pulp inspection was used as a gold standard. The real pulpal health (vital or necrotic) was determined by the presence or absence of bleeding after creating access to the pulp chamber. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of EPT, CPT and TTI were obtained for each pulp test using the binomial Clopper-Pearson exact method to establish confidence intervals. Forty-five affected teeth were tested. Forty-three were tested with EPT, CPT, and TTI, and two were tested solely with EPT and CPT. All dogs tested with EPT and TTI were included in the study whereas 21 out of 45 (47%) dogs tested with CPT were excluded. The sensitivity, specificity, PPV, NPV and accuracy were respectively 0.96, 1.00, 1.00, 0.96 and 0.98 for EPT; 1.00, 0.89, 0.92, 1.00 and 0.95 for CPT; and 0.59, 0.95, 0.94, 0.67 and 0.76 for TTI. This study concluded that EPT is a highly reliable diagnostic test to evaluate pulpal health in dogs. The high accuracy of CPT is conditional on the patient's responsiveness to stimulation applied to its control healthy teeth. TTI was the least reliable test in the study. SAGE Publications 2022-03-08 2022-06 /pmc/articles/PMC9109579/ /pubmed/35257623 http://dx.doi.org/10.1177/08987564221076363 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Studies
Proulx, Caroline
Dumais, Yvan
Beauchamp, Guy
Steagall, Paulo
Reliability of Electric Pulp Test, Cold Pulp Test or Tooth Transillumination to Assess Pulpal Health in Permanent Dog Teeth
title Reliability of Electric Pulp Test, Cold Pulp Test or Tooth Transillumination to Assess Pulpal Health in Permanent Dog Teeth
title_full Reliability of Electric Pulp Test, Cold Pulp Test or Tooth Transillumination to Assess Pulpal Health in Permanent Dog Teeth
title_fullStr Reliability of Electric Pulp Test, Cold Pulp Test or Tooth Transillumination to Assess Pulpal Health in Permanent Dog Teeth
title_full_unstemmed Reliability of Electric Pulp Test, Cold Pulp Test or Tooth Transillumination to Assess Pulpal Health in Permanent Dog Teeth
title_short Reliability of Electric Pulp Test, Cold Pulp Test or Tooth Transillumination to Assess Pulpal Health in Permanent Dog Teeth
title_sort reliability of electric pulp test, cold pulp test or tooth transillumination to assess pulpal health in permanent dog teeth
topic Original Studies
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9109579/
https://www.ncbi.nlm.nih.gov/pubmed/35257623
http://dx.doi.org/10.1177/08987564221076363
work_keys_str_mv AT proulxcaroline reliabilityofelectricpulptestcoldpulptestortoothtransilluminationtoassesspulpalhealthinpermanentdogteeth
AT dumaisyvan reliabilityofelectricpulptestcoldpulptestortoothtransilluminationtoassesspulpalhealthinpermanentdogteeth
AT beauchampguy reliabilityofelectricpulptestcoldpulptestortoothtransilluminationtoassesspulpalhealthinpermanentdogteeth
AT steagallpaulo reliabilityofelectricpulptestcoldpulptestortoothtransilluminationtoassesspulpalhealthinpermanentdogteeth