Cargando…

HIV-1 drug resistance genotyping success rates and correlates of Dried-blood spots and plasma specimen genotyping failure in a resource-limited setting

BACKGROUND: HIV-1 drug resistance genotyping is critical to the monitoring of antiretroviral treatment. Data on HIV-1 genotyping success rates of different laboratory specimen types from multiple sources is still scarce. METHODS: In this cross-sectional study, we determined the laboratory genotyping...

Descripción completa

Detalles Bibliográficos
Autores principales: Omooja, Jonah, Bbosa, Nicholas, Lule, Dan Bugembe, Nannyonjo, Maria, Lunkuse, Sandra, Nassolo, Faridah, Nabirye, Stella Esther, Suubi, Hamidah Namagembe, Kaleebu, Pontiano, Ssemwanga, Deogratius
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9112432/
https://www.ncbi.nlm.nih.gov/pubmed/35581555
http://dx.doi.org/10.1186/s12879-022-07453-9
Descripción
Sumario:BACKGROUND: HIV-1 drug resistance genotyping is critical to the monitoring of antiretroviral treatment. Data on HIV-1 genotyping success rates of different laboratory specimen types from multiple sources is still scarce. METHODS: In this cross-sectional study, we determined the laboratory genotyping success rates (GSR) and assessed the correlates of genotyping failure of 6837 unpaired dried blood spot (DBS) and plasma specimens. Specimens from multiple studies in a resource-constrained setting were analysed in our laboratory between 2016 and 2019. RESULTS: We noted an overall GSR of 65.7% and specific overall GSR for DBS and plasma of 49.8% and 85.9% respectively. The correlates of genotyping failure were viral load (VL) < 10,000 copies/mL (aOR 0.3 95% CI: 0.24–0.38; p < 0.0001), lack of viral load testing prior to genotyping (OR 0.85 95% CI: 0.77–0.94; p = 0.002), use of DBS specimens (aOR 0.10 95% CI: 0.08–0.14; p < 0.0001) and specimens from routine clinical diagnosis (aOR 1.4 95% CI: 1.10–1.75; p = 0.005). CONCLUSIONS: We report rapidly decreasing HIV-1 genotyping success rates between 2016 and 2019 with increased use of DBS specimens for genotyping and note decreasing median viral loads over the years. We recommend improvement in DBS handling, pre-genotyping viral load testing to screen samples to enhance genotyping success and the development of more sensitive assays with well-designed primers to genotype specimens with low or undetectable viral load, especially in this era where virological suppression rates are rising due to increased antiretroviral therapy roll-out.