Cargando…

Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery

BACKGROUND: The volume status of patients after major abdominal surgery constantly varies owing to postoperative diverse issues comprising fluid loss or capillary leakage secondary to systemic inflammatory reaction syndrome, et.al, the precise fluid responsiveness assessment is crucial for those pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Qian, Ji, Jingjing, Shi, Xueduo, Lu, Ziyun, Xu, Lu, Hao, Jing, Zhu, Wei, Li, Bingbing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9112503/
https://www.ncbi.nlm.nih.gov/pubmed/35581547
http://dx.doi.org/10.1186/s12871-022-01692-8
_version_ 1784709426311069696
author Ma, Qian
Ji, Jingjing
Shi, Xueduo
Lu, Ziyun
Xu, Lu
Hao, Jing
Zhu, Wei
Li, Bingbing
author_facet Ma, Qian
Ji, Jingjing
Shi, Xueduo
Lu, Ziyun
Xu, Lu
Hao, Jing
Zhu, Wei
Li, Bingbing
author_sort Ma, Qian
collection PubMed
description BACKGROUND: The volume status of patients after major abdominal surgery constantly varies owing to postoperative diverse issues comprising fluid loss or capillary leakage secondary to systemic inflammatory reaction syndrome, et.al, the precise fluid responsiveness assessment is crucial for those patients. The purpose of this study is to validate the transthoracic ultrasonographic measurement of superior and inferior vena cava variation in predicting fluid responsiveness of mechanically ventilated patients after surgery. METHODS: A total of 70 patients undergoing the scheduled major abdominal surgeries in the anesthesia ICU ward were included. The superior vena cava (SVC) collapsibility index (SVCCI), the inferior vena cava distensibility index (dIVC), SVC variation over the cardiac cycle (SVCV), and cardiac output (CO) were measured by transthoracic ultrasonography were recorded before and after fluid challenge test of 5 ml/kg crystalloid within 15 min. The responders were defined as a 15% or more increment in CO. RESULTS: Thirty patients (42.9%) responded to fluid challenge, while the remnant forty patients (57.1%) did not. The areas under the ROC curve (AUC) of SVCCI, dIVC and SVCV were 0.885 (95% CI, 0.786–0.949; P < 0.0001) and 0.727 (95% CI, 0.608–0.827; P < 0.001) and 0.751 (95% CI, 0.633–0.847; P < 0.0001), respectively. AUC(dIVC) and AUC(SVCV) were significantly lower when compared with AUC(SVCCI) (P < 0.05). The optimal cutoff values were 19% for SVCCI, 14% for dIVC, and 15% for SVCV. The gray zone for SVCCI was 20%-25% and included 15.7% of patients, while 7%-27% for dIVC including 62.9% of patients and 9%-21% for SVCV including 50% of patients. CONCLUSION: Superior vena cava-related parameters measured by transthoracic ultrasound are reliable indices to predict fluid responsiveness. The accuracy of SVCCI in mechanically ventilated patients after abdominal surgery is better than that of dIVC and SVCV. TRIAL REGISTRATION: ChiCTR-INR-17013093. The initial registration date was 24/10/2017.
format Online
Article
Text
id pubmed-9112503
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-91125032022-05-18 Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery Ma, Qian Ji, Jingjing Shi, Xueduo Lu, Ziyun Xu, Lu Hao, Jing Zhu, Wei Li, Bingbing BMC Anesthesiol Research BACKGROUND: The volume status of patients after major abdominal surgery constantly varies owing to postoperative diverse issues comprising fluid loss or capillary leakage secondary to systemic inflammatory reaction syndrome, et.al, the precise fluid responsiveness assessment is crucial for those patients. The purpose of this study is to validate the transthoracic ultrasonographic measurement of superior and inferior vena cava variation in predicting fluid responsiveness of mechanically ventilated patients after surgery. METHODS: A total of 70 patients undergoing the scheduled major abdominal surgeries in the anesthesia ICU ward were included. The superior vena cava (SVC) collapsibility index (SVCCI), the inferior vena cava distensibility index (dIVC), SVC variation over the cardiac cycle (SVCV), and cardiac output (CO) were measured by transthoracic ultrasonography were recorded before and after fluid challenge test of 5 ml/kg crystalloid within 15 min. The responders were defined as a 15% or more increment in CO. RESULTS: Thirty patients (42.9%) responded to fluid challenge, while the remnant forty patients (57.1%) did not. The areas under the ROC curve (AUC) of SVCCI, dIVC and SVCV were 0.885 (95% CI, 0.786–0.949; P < 0.0001) and 0.727 (95% CI, 0.608–0.827; P < 0.001) and 0.751 (95% CI, 0.633–0.847; P < 0.0001), respectively. AUC(dIVC) and AUC(SVCV) were significantly lower when compared with AUC(SVCCI) (P < 0.05). The optimal cutoff values were 19% for SVCCI, 14% for dIVC, and 15% for SVCV. The gray zone for SVCCI was 20%-25% and included 15.7% of patients, while 7%-27% for dIVC including 62.9% of patients and 9%-21% for SVCV including 50% of patients. CONCLUSION: Superior vena cava-related parameters measured by transthoracic ultrasound are reliable indices to predict fluid responsiveness. The accuracy of SVCCI in mechanically ventilated patients after abdominal surgery is better than that of dIVC and SVCV. TRIAL REGISTRATION: ChiCTR-INR-17013093. The initial registration date was 24/10/2017. BioMed Central 2022-05-17 /pmc/articles/PMC9112503/ /pubmed/35581547 http://dx.doi.org/10.1186/s12871-022-01692-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Ma, Qian
Ji, Jingjing
Shi, Xueduo
Lu, Ziyun
Xu, Lu
Hao, Jing
Zhu, Wei
Li, Bingbing
Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery
title Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery
title_full Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery
title_fullStr Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery
title_full_unstemmed Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery
title_short Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery
title_sort comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9112503/
https://www.ncbi.nlm.nih.gov/pubmed/35581547
http://dx.doi.org/10.1186/s12871-022-01692-8
work_keys_str_mv AT maqian comparisonofsuperiorandinferiorvenacavadiametervariationmeasuredwithtransthoracicechocardiographytopredictfluidresponsivenessinmechanicallyventilatedpatientsafterabdominalsurgery
AT jijingjing comparisonofsuperiorandinferiorvenacavadiametervariationmeasuredwithtransthoracicechocardiographytopredictfluidresponsivenessinmechanicallyventilatedpatientsafterabdominalsurgery
AT shixueduo comparisonofsuperiorandinferiorvenacavadiametervariationmeasuredwithtransthoracicechocardiographytopredictfluidresponsivenessinmechanicallyventilatedpatientsafterabdominalsurgery
AT luziyun comparisonofsuperiorandinferiorvenacavadiametervariationmeasuredwithtransthoracicechocardiographytopredictfluidresponsivenessinmechanicallyventilatedpatientsafterabdominalsurgery
AT xulu comparisonofsuperiorandinferiorvenacavadiametervariationmeasuredwithtransthoracicechocardiographytopredictfluidresponsivenessinmechanicallyventilatedpatientsafterabdominalsurgery
AT haojing comparisonofsuperiorandinferiorvenacavadiametervariationmeasuredwithtransthoracicechocardiographytopredictfluidresponsivenessinmechanicallyventilatedpatientsafterabdominalsurgery
AT zhuwei comparisonofsuperiorandinferiorvenacavadiametervariationmeasuredwithtransthoracicechocardiographytopredictfluidresponsivenessinmechanicallyventilatedpatientsafterabdominalsurgery
AT libingbing comparisonofsuperiorandinferiorvenacavadiametervariationmeasuredwithtransthoracicechocardiographytopredictfluidresponsivenessinmechanicallyventilatedpatientsafterabdominalsurgery