Early outcomes of 21-gauge needle-guided ab interno tube sulcus placement of a non-valved implant in pseudophakic eyes
We report the early outcomes and describe an ab interno 21-G needle technique of sulcus placement of the Aurolab aqueous drainage implant (AADI) tube in nine pseudophakic eyes. IOP reduced from a preoperative mean (SD) of 28.33 (9.80) to 11.56 (2.65) mm Hg and the mean (SD) number of preoperative me...