Cargando…

Investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal

SIGNIFICANCE: There is a longstanding recommendation within the field of fNIRS to use oxygenated ([Formula: see text]) and deoxygenated (HHb) hemoglobin when analyzing and interpreting results. Despite this, many fNIRS studies do focus on [Formula: see text] only. Previous work has shown that [Formu...

Descripción completa

Detalles Bibliográficos
Autores principales: Hakim, Uzair, Pinti, Paola, Noah, Adam J., Zhang, Xian, Burgess, Paul, Hamilton, Antonia, Hirsch, Joy, Tachtsidis, Ilias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9116886/
https://www.ncbi.nlm.nih.gov/pubmed/35599691
http://dx.doi.org/10.1117/1.NPh.9.2.025001
_version_ 1784710208680886272
author Hakim, Uzair
Pinti, Paola
Noah, Adam J.
Zhang, Xian
Burgess, Paul
Hamilton, Antonia
Hirsch, Joy
Tachtsidis, Ilias
author_facet Hakim, Uzair
Pinti, Paola
Noah, Adam J.
Zhang, Xian
Burgess, Paul
Hamilton, Antonia
Hirsch, Joy
Tachtsidis, Ilias
author_sort Hakim, Uzair
collection PubMed
description SIGNIFICANCE: There is a longstanding recommendation within the field of fNIRS to use oxygenated ([Formula: see text]) and deoxygenated (HHb) hemoglobin when analyzing and interpreting results. Despite this, many fNIRS studies do focus on [Formula: see text] only. Previous work has shown that [Formula: see text] on its own is susceptible to systemic interference and results may mostly reflect that rather than functional activation. Studies using both [Formula: see text] and HHb to draw their conclusions do so with varying methods and can lead to discrepancies between studies. The combination of [Formula: see text] and HHb has been recommended as a method to utilize both signals in analysis. AIM: We present the development of the hemodynamic phase correlation (HPC) signal to combine [Formula: see text] and HHb as recommended to utilize both signals in the analysis. We use synthetic and experimental data to evaluate how the HPC and current signals used for fNIRS analysis compare. APPROACH: About 18 synthetic datasets were formed using resting-state fNIRS data acquired from 16 channels over the frontal lobe. To simulate fNIRS data for a block-design task, we superimposed a synthetic task-related hemodynamic response to the resting state data. This data was used to develop an HPC-general linear model (GLM) framework. Experiments were conducted to investigate the performance of each signal at different SNR and to investigate the effect of false positives on the data. Performance was based on each signal’s mean [Formula: see text]-value across channels. Experimental data recorded from 128 participants across 134 channels during a finger-tapping task were used to investigate the performance of multiple signals [[Formula: see text] , HHb, HbT, HbD, correlation-based signal improvement (CBSI), and HPC] on real data. Signal performance was evaluated on its ability to localize activation to a specific region of interest. RESULTS: Results from varying the SNR show that the HPC signal has the highest performance for high SNRs. The CBSI performed the best for medium-low SNR. The next analysis evaluated how false positives affect the signals. The analyses evaluating the effect of false positives showed that the HPC and CBSI signals reflect the effect of false positives on [Formula: see text] and HHb. The analysis of real experimental data revealed that the HPC and HHb signals provide localization to the primary motor cortex with the highest accuracy. CONCLUSIONS: We developed a new hemodynamic signal (HPC) with the potential to overcome the current limitations of using [Formula: see text] and HHb separately. Our results suggest that the HPC signal provides comparable accuracy to HHb to localize functional activation while at the same time being more robust against false positives.
format Online
Article
Text
id pubmed-9116886
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-91168862022-05-21 Investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal Hakim, Uzair Pinti, Paola Noah, Adam J. Zhang, Xian Burgess, Paul Hamilton, Antonia Hirsch, Joy Tachtsidis, Ilias Neurophotonics Research Papers SIGNIFICANCE: There is a longstanding recommendation within the field of fNIRS to use oxygenated ([Formula: see text]) and deoxygenated (HHb) hemoglobin when analyzing and interpreting results. Despite this, many fNIRS studies do focus on [Formula: see text] only. Previous work has shown that [Formula: see text] on its own is susceptible to systemic interference and results may mostly reflect that rather than functional activation. Studies using both [Formula: see text] and HHb to draw their conclusions do so with varying methods and can lead to discrepancies between studies. The combination of [Formula: see text] and HHb has been recommended as a method to utilize both signals in analysis. AIM: We present the development of the hemodynamic phase correlation (HPC) signal to combine [Formula: see text] and HHb as recommended to utilize both signals in the analysis. We use synthetic and experimental data to evaluate how the HPC and current signals used for fNIRS analysis compare. APPROACH: About 18 synthetic datasets were formed using resting-state fNIRS data acquired from 16 channels over the frontal lobe. To simulate fNIRS data for a block-design task, we superimposed a synthetic task-related hemodynamic response to the resting state data. This data was used to develop an HPC-general linear model (GLM) framework. Experiments were conducted to investigate the performance of each signal at different SNR and to investigate the effect of false positives on the data. Performance was based on each signal’s mean [Formula: see text]-value across channels. Experimental data recorded from 128 participants across 134 channels during a finger-tapping task were used to investigate the performance of multiple signals [[Formula: see text] , HHb, HbT, HbD, correlation-based signal improvement (CBSI), and HPC] on real data. Signal performance was evaluated on its ability to localize activation to a specific region of interest. RESULTS: Results from varying the SNR show that the HPC signal has the highest performance for high SNRs. The CBSI performed the best for medium-low SNR. The next analysis evaluated how false positives affect the signals. The analyses evaluating the effect of false positives showed that the HPC and CBSI signals reflect the effect of false positives on [Formula: see text] and HHb. The analysis of real experimental data revealed that the HPC and HHb signals provide localization to the primary motor cortex with the highest accuracy. CONCLUSIONS: We developed a new hemodynamic signal (HPC) with the potential to overcome the current limitations of using [Formula: see text] and HHb separately. Our results suggest that the HPC signal provides comparable accuracy to HHb to localize functional activation while at the same time being more robust against false positives. Society of Photo-Optical Instrumentation Engineers 2022-05-18 2022-04 /pmc/articles/PMC9116886/ /pubmed/35599691 http://dx.doi.org/10.1117/1.NPh.9.2.025001 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Research Papers
Hakim, Uzair
Pinti, Paola
Noah, Adam J.
Zhang, Xian
Burgess, Paul
Hamilton, Antonia
Hirsch, Joy
Tachtsidis, Ilias
Investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal
title Investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal
title_full Investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal
title_fullStr Investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal
title_full_unstemmed Investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal
title_short Investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal
title_sort investigation of functional near-infrared spectroscopy signal quality and development of the hemodynamic phase correlation signal
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9116886/
https://www.ncbi.nlm.nih.gov/pubmed/35599691
http://dx.doi.org/10.1117/1.NPh.9.2.025001
work_keys_str_mv AT hakimuzair investigationoffunctionalnearinfraredspectroscopysignalqualityanddevelopmentofthehemodynamicphasecorrelationsignal
AT pintipaola investigationoffunctionalnearinfraredspectroscopysignalqualityanddevelopmentofthehemodynamicphasecorrelationsignal
AT noahadamj investigationoffunctionalnearinfraredspectroscopysignalqualityanddevelopmentofthehemodynamicphasecorrelationsignal
AT zhangxian investigationoffunctionalnearinfraredspectroscopysignalqualityanddevelopmentofthehemodynamicphasecorrelationsignal
AT burgesspaul investigationoffunctionalnearinfraredspectroscopysignalqualityanddevelopmentofthehemodynamicphasecorrelationsignal
AT hamiltonantonia investigationoffunctionalnearinfraredspectroscopysignalqualityanddevelopmentofthehemodynamicphasecorrelationsignal
AT hirschjoy investigationoffunctionalnearinfraredspectroscopysignalqualityanddevelopmentofthehemodynamicphasecorrelationsignal
AT tachtsidisilias investigationoffunctionalnearinfraredspectroscopysignalqualityanddevelopmentofthehemodynamicphasecorrelationsignal