Cargando…
Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants
Hip and knee joint replacements are common and largely successful procedures that utilise implants to restore mobility and relieve pain for patients suffering from e.g. osteoarthritis. However, metallic ions and particles released from both the bearing surfaces and non-articulating interfaces, as in...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9118168/ https://www.ncbi.nlm.nih.gov/pubmed/35601891 http://dx.doi.org/10.1016/j.mtbio.2022.100270 |
_version_ | 1784710456399626240 |
---|---|
author | Skjöldebrand, Charlotte Tipper, Joanne L. Hatto, Peter Bryant, Michael Hall, Richard M. Persson, Cecilia |
author_facet | Skjöldebrand, Charlotte Tipper, Joanne L. Hatto, Peter Bryant, Michael Hall, Richard M. Persson, Cecilia |
author_sort | Skjöldebrand, Charlotte |
collection | PubMed |
description | Hip and knee joint replacements are common and largely successful procedures that utilise implants to restore mobility and relieve pain for patients suffering from e.g. osteoarthritis. However, metallic ions and particles released from both the bearing surfaces and non-articulating interfaces, as in modular components, can cause hypersensitivity and local tissue necrosis, while particles originating from a polymer component have been associated with aseptic loosening and osteolysis. Implant coatings have the potential to improve properties compared to both bulk metal and ceramic alternatives. Ceramic coatings have the potential to increase scratch resistance, enhance wettability and reduce wear of the articulating surfaces compared to the metallic substrate, whilst maintaining overall toughness of the implant ensuring a lower risk of catastrophic failure of the device compared to use of a bulk ceramic. Coatings can also act as barriers to inhibit ion release from the underlying material caused by corrosion. This review aims to provide a comprehensive overview of wear-resistant coatings for joint replacements – both those that are in current clinical use as well as those under investigation for future use. While the majority of coatings belong predominantly in the latter group, a few coated implants have been successfully marketed and are available for clinical use in specific applications. Commercially available coatings for implants include titanium nitride (TiN), titanium niobium nitride (TiNbN), oxidized zirconium (OxZr) and zirconium nitride (ZrN) based coatings, whereas current research is focused not only on these, but also on diamond-like-carbon (DLC), silicon nitride (SiN), chromium nitride (CrN) and tantalum-based coatings (TaN and TaO). The coating materials referred to above that are still at the research stage have been shown to be non-cytotoxic and to reduce wear in a laboratory setting. However, the adhesion of implant coatings remains a main area of concern, as poor adhesion can cause delamination and excessive wear. In clinical applications zirconium implant surfaces treated to achieve a zirconium oxide film and TiNbN coated implants have however been proven comparable to traditional cobalt chromium implants with regards to revision numbers. In addition, the chromium ion levels measured in the plasma of patients were lower and allergy symptoms were relieved. Therefore, coated implants could be considered an alternative to uncoated metal implants, in particular for patients with metal hypersensitivity. There have also been unsuccessful introductions to the market, such as DLC coated implants, and therefore this review also attempts to summarize the lessons learnt. |
format | Online Article Text |
id | pubmed-9118168 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-91181682022-05-20 Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants Skjöldebrand, Charlotte Tipper, Joanne L. Hatto, Peter Bryant, Michael Hall, Richard M. Persson, Cecilia Mater Today Bio Review Article Hip and knee joint replacements are common and largely successful procedures that utilise implants to restore mobility and relieve pain for patients suffering from e.g. osteoarthritis. However, metallic ions and particles released from both the bearing surfaces and non-articulating interfaces, as in modular components, can cause hypersensitivity and local tissue necrosis, while particles originating from a polymer component have been associated with aseptic loosening and osteolysis. Implant coatings have the potential to improve properties compared to both bulk metal and ceramic alternatives. Ceramic coatings have the potential to increase scratch resistance, enhance wettability and reduce wear of the articulating surfaces compared to the metallic substrate, whilst maintaining overall toughness of the implant ensuring a lower risk of catastrophic failure of the device compared to use of a bulk ceramic. Coatings can also act as barriers to inhibit ion release from the underlying material caused by corrosion. This review aims to provide a comprehensive overview of wear-resistant coatings for joint replacements – both those that are in current clinical use as well as those under investigation for future use. While the majority of coatings belong predominantly in the latter group, a few coated implants have been successfully marketed and are available for clinical use in specific applications. Commercially available coatings for implants include titanium nitride (TiN), titanium niobium nitride (TiNbN), oxidized zirconium (OxZr) and zirconium nitride (ZrN) based coatings, whereas current research is focused not only on these, but also on diamond-like-carbon (DLC), silicon nitride (SiN), chromium nitride (CrN) and tantalum-based coatings (TaN and TaO). The coating materials referred to above that are still at the research stage have been shown to be non-cytotoxic and to reduce wear in a laboratory setting. However, the adhesion of implant coatings remains a main area of concern, as poor adhesion can cause delamination and excessive wear. In clinical applications zirconium implant surfaces treated to achieve a zirconium oxide film and TiNbN coated implants have however been proven comparable to traditional cobalt chromium implants with regards to revision numbers. In addition, the chromium ion levels measured in the plasma of patients were lower and allergy symptoms were relieved. Therefore, coated implants could be considered an alternative to uncoated metal implants, in particular for patients with metal hypersensitivity. There have also been unsuccessful introductions to the market, such as DLC coated implants, and therefore this review also attempts to summarize the lessons learnt. Elsevier 2022-04-30 /pmc/articles/PMC9118168/ /pubmed/35601891 http://dx.doi.org/10.1016/j.mtbio.2022.100270 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Article Skjöldebrand, Charlotte Tipper, Joanne L. Hatto, Peter Bryant, Michael Hall, Richard M. Persson, Cecilia Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants |
title | Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants |
title_full | Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants |
title_fullStr | Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants |
title_full_unstemmed | Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants |
title_short | Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants |
title_sort | current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9118168/ https://www.ncbi.nlm.nih.gov/pubmed/35601891 http://dx.doi.org/10.1016/j.mtbio.2022.100270 |
work_keys_str_mv | AT skjoldebrandcharlotte currentstatusandfuturepotentialofwearresistantcoatingsandarticulatingsurfacesforhipandkneeimplants AT tipperjoannel currentstatusandfuturepotentialofwearresistantcoatingsandarticulatingsurfacesforhipandkneeimplants AT hattopeter currentstatusandfuturepotentialofwearresistantcoatingsandarticulatingsurfacesforhipandkneeimplants AT bryantmichael currentstatusandfuturepotentialofwearresistantcoatingsandarticulatingsurfacesforhipandkneeimplants AT hallrichardm currentstatusandfuturepotentialofwearresistantcoatingsandarticulatingsurfacesforhipandkneeimplants AT perssoncecilia currentstatusandfuturepotentialofwearresistantcoatingsandarticulatingsurfacesforhipandkneeimplants |