Cargando…

The effects of amalgam contamination and different surface modifications on microleakage of dentin bonded to bulk fill composite when using different adhesive protocols

BACKGROUND: To evaluate the effect of amalgam contamination, different surface treatments, and adhesive protocols on dentin microleakage to bulk-fill composite resin material. METHODS: Forty teeth were fixed in (polyvinyl siloxane) PVS molds, and the Class II cavities were placed on mesial and dista...

Descripción completa

Detalles Bibliográficos
Autores principales: Alshehri, Nojoud, Aljamhan, Abdullah, Bin-Shuwaish, Mohammed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9118798/
https://www.ncbi.nlm.nih.gov/pubmed/35585533
http://dx.doi.org/10.1186/s12903-022-02214-1
_version_ 1784710574704164864
author Alshehri, Nojoud
Aljamhan, Abdullah
Bin-Shuwaish, Mohammed
author_facet Alshehri, Nojoud
Aljamhan, Abdullah
Bin-Shuwaish, Mohammed
author_sort Alshehri, Nojoud
collection PubMed
description BACKGROUND: To evaluate the effect of amalgam contamination, different surface treatments, and adhesive protocols on dentin microleakage to bulk-fill composite resin material. METHODS: Forty teeth were fixed in (polyvinyl siloxane) PVS molds, and the Class II cavities were placed on mesial and distal aspects. Thirty teeth were restored by amalgam and thermocycled to 10,000 cycles (5 and 55 °C, 30-s dwell time). The rest were restored with Filtek one Bulk Fill composite without amalgam predecessor. Samples were divided into: G1 (dentin pretreated with 2% chlorhexidine gluconate), G2 (0.5 mm of dentin was removed), G3 (no surface modification), and G4 (control, where composite was bonded to sound dentin without amalgam predecessor.). Single Bond Universal Adhesive system was used to bond the composite material, by using the etch-and-rinse protocol in the mesial cavity preparation and self-etch protocol in the distal. Specimens underwent thermocycling for 5000 cycles, then embedded in silver nitrate and sectioned for stereomicroscope examination. Descriptive statistics, Mann–Whitney U test, and Kruskal–Wallis test were used to analyze the results at p < 0.05. RESULTS: The highest microleakage score values (4.00) were found in the G2, and G4 in etch-and-rinse protocol. While the lowest scores were found in G2 when using self-etching protocol (1.5). Lower microleakage values were associated with the chlorhexidine treatment group for both adhesive protocols. No significant differences were found between amalgam contaminated and non-contaminated groups. CONCLUSIONS: Amalgam contamination did not affect microleakage. Self-etching adhesive protocol significantly reduced microleakage for all groups irrespective of the surface treatment. Chlorhexidine pretreatment improved microleakage for both adhesive protocols but had no significant effect.
format Online
Article
Text
id pubmed-9118798
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-91187982022-05-20 The effects of amalgam contamination and different surface modifications on microleakage of dentin bonded to bulk fill composite when using different adhesive protocols Alshehri, Nojoud Aljamhan, Abdullah Bin-Shuwaish, Mohammed BMC Oral Health Research BACKGROUND: To evaluate the effect of amalgam contamination, different surface treatments, and adhesive protocols on dentin microleakage to bulk-fill composite resin material. METHODS: Forty teeth were fixed in (polyvinyl siloxane) PVS molds, and the Class II cavities were placed on mesial and distal aspects. Thirty teeth were restored by amalgam and thermocycled to 10,000 cycles (5 and 55 °C, 30-s dwell time). The rest were restored with Filtek one Bulk Fill composite without amalgam predecessor. Samples were divided into: G1 (dentin pretreated with 2% chlorhexidine gluconate), G2 (0.5 mm of dentin was removed), G3 (no surface modification), and G4 (control, where composite was bonded to sound dentin without amalgam predecessor.). Single Bond Universal Adhesive system was used to bond the composite material, by using the etch-and-rinse protocol in the mesial cavity preparation and self-etch protocol in the distal. Specimens underwent thermocycling for 5000 cycles, then embedded in silver nitrate and sectioned for stereomicroscope examination. Descriptive statistics, Mann–Whitney U test, and Kruskal–Wallis test were used to analyze the results at p < 0.05. RESULTS: The highest microleakage score values (4.00) were found in the G2, and G4 in etch-and-rinse protocol. While the lowest scores were found in G2 when using self-etching protocol (1.5). Lower microleakage values were associated with the chlorhexidine treatment group for both adhesive protocols. No significant differences were found between amalgam contaminated and non-contaminated groups. CONCLUSIONS: Amalgam contamination did not affect microleakage. Self-etching adhesive protocol significantly reduced microleakage for all groups irrespective of the surface treatment. Chlorhexidine pretreatment improved microleakage for both adhesive protocols but had no significant effect. BioMed Central 2022-05-18 /pmc/articles/PMC9118798/ /pubmed/35585533 http://dx.doi.org/10.1186/s12903-022-02214-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Alshehri, Nojoud
Aljamhan, Abdullah
Bin-Shuwaish, Mohammed
The effects of amalgam contamination and different surface modifications on microleakage of dentin bonded to bulk fill composite when using different adhesive protocols
title The effects of amalgam contamination and different surface modifications on microleakage of dentin bonded to bulk fill composite when using different adhesive protocols
title_full The effects of amalgam contamination and different surface modifications on microleakage of dentin bonded to bulk fill composite when using different adhesive protocols
title_fullStr The effects of amalgam contamination and different surface modifications on microleakage of dentin bonded to bulk fill composite when using different adhesive protocols
title_full_unstemmed The effects of amalgam contamination and different surface modifications on microleakage of dentin bonded to bulk fill composite when using different adhesive protocols
title_short The effects of amalgam contamination and different surface modifications on microleakage of dentin bonded to bulk fill composite when using different adhesive protocols
title_sort effects of amalgam contamination and different surface modifications on microleakage of dentin bonded to bulk fill composite when using different adhesive protocols
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9118798/
https://www.ncbi.nlm.nih.gov/pubmed/35585533
http://dx.doi.org/10.1186/s12903-022-02214-1
work_keys_str_mv AT alshehrinojoud theeffectsofamalgamcontaminationanddifferentsurfacemodificationsonmicroleakageofdentinbondedtobulkfillcompositewhenusingdifferentadhesiveprotocols
AT aljamhanabdullah theeffectsofamalgamcontaminationanddifferentsurfacemodificationsonmicroleakageofdentinbondedtobulkfillcompositewhenusingdifferentadhesiveprotocols
AT binshuwaishmohammed theeffectsofamalgamcontaminationanddifferentsurfacemodificationsonmicroleakageofdentinbondedtobulkfillcompositewhenusingdifferentadhesiveprotocols
AT alshehrinojoud effectsofamalgamcontaminationanddifferentsurfacemodificationsonmicroleakageofdentinbondedtobulkfillcompositewhenusingdifferentadhesiveprotocols
AT aljamhanabdullah effectsofamalgamcontaminationanddifferentsurfacemodificationsonmicroleakageofdentinbondedtobulkfillcompositewhenusingdifferentadhesiveprotocols
AT binshuwaishmohammed effectsofamalgamcontaminationanddifferentsurfacemodificationsonmicroleakageofdentinbondedtobulkfillcompositewhenusingdifferentadhesiveprotocols