Cargando…

Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study

Ankle-Foot Orthoses (AFO) can be prescribed to allow drop-foot patients to restore a quasi-normal gait pattern. Standard off-the-shelf AFOs are cost-effective solutions to treat most patients with foot and ankle weakness, but these devices have several limitations, especially in terms of comfort. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Rogati, Giulia, Caravaggi, Paolo, Leardini, Alberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9118871/
https://www.ncbi.nlm.nih.gov/pubmed/35585544
http://dx.doi.org/10.1186/s13047-022-00547-2
_version_ 1784710591142690816
author Rogati, Giulia
Caravaggi, Paolo
Leardini, Alberto
author_facet Rogati, Giulia
Caravaggi, Paolo
Leardini, Alberto
author_sort Rogati, Giulia
collection PubMed
description Ankle-Foot Orthoses (AFO) can be prescribed to allow drop-foot patients to restore a quasi-normal gait pattern. Standard off-the-shelf AFOs are cost-effective solutions to treat most patients with foot and ankle weakness, but these devices have several limitations, especially in terms of comfort. Therefore, custom AFOs are increasingly adopted to address drop-foot when standard solutions are not adequate. While the solid ones are the most common type of AFO, providing full stability and strong resistance to ankle plantarflexion, passive dynamic AFOs (PD-AFOs) represent the ideal solution for patients with less severe ankle weakness. PD-AFOs have a flexible calf shell, which can bend during the stance phase of walking and absorb energy that can be released to support the limb in the push-off phase. The aim of this review is to assess the state-of-the-art and identify the current limitations of PD-AFOs. An extensive literature review was performed in Google Scholar to identify all studies on custom PD-AFOs. Only those papers reporting on custom PD-AFOs were included in the review. Non peer-reviewed papers, abstract shorter than three pages, lecture notes and thesis dissertations were excluded from the analysis. Particular attention was given to the customization principles and the mechanical and functional tests. For each topic, the main results from all relevant papers are reported and summarized herein. There were 75 papers that corresponded to the search criteria. These were grouped according to the following macro-topics: 16 focusing on scanning technologies and geometry acquisition; 14 on customization criteria; 19 on production techniques; 16 on mechanical testing, and 33 on functional testing. According to the present review, design and production of custom PD-AFOs are becoming increasingly feasible due to advancements in 3D scanning techniques and additive manufacturing. In general, custom PD-AFOs were shown to provide better comfort and improved spatio-temporal parameters with respect to standard solutions. However, no customization principle to adapt PD-AFO stiffness to the patient’s degree of ankle impairment or mechanical/functional demand has thus far been proposed.
format Online
Article
Text
id pubmed-9118871
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-91188712022-05-20 Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study Rogati, Giulia Caravaggi, Paolo Leardini, Alberto J Foot Ankle Res Review Ankle-Foot Orthoses (AFO) can be prescribed to allow drop-foot patients to restore a quasi-normal gait pattern. Standard off-the-shelf AFOs are cost-effective solutions to treat most patients with foot and ankle weakness, but these devices have several limitations, especially in terms of comfort. Therefore, custom AFOs are increasingly adopted to address drop-foot when standard solutions are not adequate. While the solid ones are the most common type of AFO, providing full stability and strong resistance to ankle plantarflexion, passive dynamic AFOs (PD-AFOs) represent the ideal solution for patients with less severe ankle weakness. PD-AFOs have a flexible calf shell, which can bend during the stance phase of walking and absorb energy that can be released to support the limb in the push-off phase. The aim of this review is to assess the state-of-the-art and identify the current limitations of PD-AFOs. An extensive literature review was performed in Google Scholar to identify all studies on custom PD-AFOs. Only those papers reporting on custom PD-AFOs were included in the review. Non peer-reviewed papers, abstract shorter than three pages, lecture notes and thesis dissertations were excluded from the analysis. Particular attention was given to the customization principles and the mechanical and functional tests. For each topic, the main results from all relevant papers are reported and summarized herein. There were 75 papers that corresponded to the search criteria. These were grouped according to the following macro-topics: 16 focusing on scanning technologies and geometry acquisition; 14 on customization criteria; 19 on production techniques; 16 on mechanical testing, and 33 on functional testing. According to the present review, design and production of custom PD-AFOs are becoming increasingly feasible due to advancements in 3D scanning techniques and additive manufacturing. In general, custom PD-AFOs were shown to provide better comfort and improved spatio-temporal parameters with respect to standard solutions. However, no customization principle to adapt PD-AFO stiffness to the patient’s degree of ankle impairment or mechanical/functional demand has thus far been proposed. BioMed Central 2022-05-19 /pmc/articles/PMC9118871/ /pubmed/35585544 http://dx.doi.org/10.1186/s13047-022-00547-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Review
Rogati, Giulia
Caravaggi, Paolo
Leardini, Alberto
Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study
title Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study
title_full Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study
title_fullStr Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study
title_full_unstemmed Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study
title_short Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study
title_sort design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9118871/
https://www.ncbi.nlm.nih.gov/pubmed/35585544
http://dx.doi.org/10.1186/s13047-022-00547-2
work_keys_str_mv AT rogatigiulia designprinciplesmanufacturingandevaluationtechniquesofcustomdynamicanklefootorthosesareviewstudy
AT caravaggipaolo designprinciplesmanufacturingandevaluationtechniquesofcustomdynamicanklefootorthosesareviewstudy
AT leardinialberto designprinciplesmanufacturingandevaluationtechniquesofcustomdynamicanklefootorthosesareviewstudy