Cargando…

Factors Associated with Pulmonary Function Changes in Patients Undergoing Microwave Ablation for Pulmonary Ground-Glass Nodules

Purpose: Microwave ablation has become an alternative treatment for pulmonary ground-glass nodules (GGN) and is widely accepted by clinicians. However, its effect on lung function remains unknown. Therefore, this retrospective study aimed to explore pulmonary function changes and associated risk fac...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Weida, Peng, Jianyang, Gao, Hongbin, Lin, Yuanzhen, Lin, Qunying, Weng, Zhicheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9118901/
https://www.ncbi.nlm.nih.gov/pubmed/35546547
http://dx.doi.org/10.1177/15330338221094429
_version_ 1784710597977309184
author Wu, Weida
Peng, Jianyang
Gao, Hongbin
Lin, Yuanzhen
Lin, Qunying
Weng, Zhicheng
author_facet Wu, Weida
Peng, Jianyang
Gao, Hongbin
Lin, Yuanzhen
Lin, Qunying
Weng, Zhicheng
author_sort Wu, Weida
collection PubMed
description Purpose: Microwave ablation has become an alternative treatment for pulmonary ground-glass nodules (GGN) and is widely accepted by clinicians. However, its effect on lung function remains unknown. Therefore, this retrospective study aimed to explore pulmonary function changes and associated risk factors in patients undergoing computed tomography (CT)-guided microwave ablation (MWA) for treating pulmonary GGN. Materials and Methods: Thirty-five patients diagnosed with pulmonary GGN on thin-layer chest CT and enhanced CT were examined. Patients unable or unwilling to undergo thoracoscopic surgery underwent CT-guided simultaneous percutaneous core needle biopsy and MWA. Pulmonary function tests (PFT) were performed before ablation and 3 days and 6 months post-ablation. Forced expiratory volume in one second (FEV1), FEV1%, forced vital capacity (FVC), maximal voluntary ventilation (MVV), and peak expiratory flow (PEF) values pre- and post-MWA were analysed. Linear regression analysis was used to examine the correlation between ablation volume and changes in PFT findings 3 days post-ablation. Associations between patient characteristics, rates of postoperative complications, and PFT findings were analysed. Results: Forty-eight lesions were completely ablated and examined intraoperatively. There were significant differences in pre- and post-operative PFT findings on day 3 but not at 6 months. The mean ablation volume after 3 days of 11.4 ± 6.3 cm(3) was positively correlated with changes in FEV1, MVV, and PEF values. Patients’ age (mean, 59.4 ± 13.0 years) positively correlated with changes in PEF values. The rates of change in FVC and MVV values were significantly higher with multiple pulmonary nodules than with isolated pulmonary nodule. PFT findings were similar between patients who experienced or did not experience complications (eg, pneumothorax and pleural effusion). Conclusions: Pulmonary function could be impaired shortly after MWA. PFT findings may correlate with age, ablation volume, and number of ablated lesions. In most patients, pulmonary function returned to the preoperative state after 6 months.
format Online
Article
Text
id pubmed-9118901
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-91189012022-05-20 Factors Associated with Pulmonary Function Changes in Patients Undergoing Microwave Ablation for Pulmonary Ground-Glass Nodules Wu, Weida Peng, Jianyang Gao, Hongbin Lin, Yuanzhen Lin, Qunying Weng, Zhicheng Technol Cancer Res Treat Original Article Purpose: Microwave ablation has become an alternative treatment for pulmonary ground-glass nodules (GGN) and is widely accepted by clinicians. However, its effect on lung function remains unknown. Therefore, this retrospective study aimed to explore pulmonary function changes and associated risk factors in patients undergoing computed tomography (CT)-guided microwave ablation (MWA) for treating pulmonary GGN. Materials and Methods: Thirty-five patients diagnosed with pulmonary GGN on thin-layer chest CT and enhanced CT were examined. Patients unable or unwilling to undergo thoracoscopic surgery underwent CT-guided simultaneous percutaneous core needle biopsy and MWA. Pulmonary function tests (PFT) were performed before ablation and 3 days and 6 months post-ablation. Forced expiratory volume in one second (FEV1), FEV1%, forced vital capacity (FVC), maximal voluntary ventilation (MVV), and peak expiratory flow (PEF) values pre- and post-MWA were analysed. Linear regression analysis was used to examine the correlation between ablation volume and changes in PFT findings 3 days post-ablation. Associations between patient characteristics, rates of postoperative complications, and PFT findings were analysed. Results: Forty-eight lesions were completely ablated and examined intraoperatively. There were significant differences in pre- and post-operative PFT findings on day 3 but not at 6 months. The mean ablation volume after 3 days of 11.4 ± 6.3 cm(3) was positively correlated with changes in FEV1, MVV, and PEF values. Patients’ age (mean, 59.4 ± 13.0 years) positively correlated with changes in PEF values. The rates of change in FVC and MVV values were significantly higher with multiple pulmonary nodules than with isolated pulmonary nodule. PFT findings were similar between patients who experienced or did not experience complications (eg, pneumothorax and pleural effusion). Conclusions: Pulmonary function could be impaired shortly after MWA. PFT findings may correlate with age, ablation volume, and number of ablated lesions. In most patients, pulmonary function returned to the preoperative state after 6 months. SAGE Publications 2022-05-12 /pmc/articles/PMC9118901/ /pubmed/35546547 http://dx.doi.org/10.1177/15330338221094429 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Wu, Weida
Peng, Jianyang
Gao, Hongbin
Lin, Yuanzhen
Lin, Qunying
Weng, Zhicheng
Factors Associated with Pulmonary Function Changes in Patients Undergoing Microwave Ablation for Pulmonary Ground-Glass Nodules
title Factors Associated with Pulmonary Function Changes in Patients Undergoing Microwave Ablation for Pulmonary Ground-Glass Nodules
title_full Factors Associated with Pulmonary Function Changes in Patients Undergoing Microwave Ablation for Pulmonary Ground-Glass Nodules
title_fullStr Factors Associated with Pulmonary Function Changes in Patients Undergoing Microwave Ablation for Pulmonary Ground-Glass Nodules
title_full_unstemmed Factors Associated with Pulmonary Function Changes in Patients Undergoing Microwave Ablation for Pulmonary Ground-Glass Nodules
title_short Factors Associated with Pulmonary Function Changes in Patients Undergoing Microwave Ablation for Pulmonary Ground-Glass Nodules
title_sort factors associated with pulmonary function changes in patients undergoing microwave ablation for pulmonary ground-glass nodules
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9118901/
https://www.ncbi.nlm.nih.gov/pubmed/35546547
http://dx.doi.org/10.1177/15330338221094429
work_keys_str_mv AT wuweida factorsassociatedwithpulmonaryfunctionchangesinpatientsundergoingmicrowaveablationforpulmonarygroundglassnodules
AT pengjianyang factorsassociatedwithpulmonaryfunctionchangesinpatientsundergoingmicrowaveablationforpulmonarygroundglassnodules
AT gaohongbin factorsassociatedwithpulmonaryfunctionchangesinpatientsundergoingmicrowaveablationforpulmonarygroundglassnodules
AT linyuanzhen factorsassociatedwithpulmonaryfunctionchangesinpatientsundergoingmicrowaveablationforpulmonarygroundglassnodules
AT linqunying factorsassociatedwithpulmonaryfunctionchangesinpatientsundergoingmicrowaveablationforpulmonarygroundglassnodules
AT wengzhicheng factorsassociatedwithpulmonaryfunctionchangesinpatientsundergoingmicrowaveablationforpulmonarygroundglassnodules