Cargando…

Surgical Technique for Concurrent Endoscopic Carpal Tunnel Release and Distal Radius Fracture Fixation Using the Flexor Carpi Radialis Approach: A Case Series

PURPOSE: Multiple prior studies have assessed the results of open approaches for concurrent carpal tunnel release with distal radius fracture fixation; however, less is known regarding the feasibility of endoscopic techniques, especially in the setting of high-energy trauma. In this study, we assess...

Descripción completa

Detalles Bibliográficos
Autores principales: Bhashyam, Abhiram R., Kao, Dennis S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9120784/
https://www.ncbi.nlm.nih.gov/pubmed/35601523
http://dx.doi.org/10.1016/j.jhsg.2021.11.007
_version_ 1784711008423510016
author Bhashyam, Abhiram R.
Kao, Dennis S.
author_facet Bhashyam, Abhiram R.
Kao, Dennis S.
author_sort Bhashyam, Abhiram R.
collection PubMed
description PURPOSE: Multiple prior studies have assessed the results of open approaches for concurrent carpal tunnel release with distal radius fracture fixation; however, less is known regarding the feasibility of endoscopic techniques, especially in the setting of high-energy trauma. In this study, we assessed the feasibility and results of concurrent endoscopic carpal tunnel release and distal radius fracture fixation using the flexor carpi radialis approach after high- and low-energy trauma. METHODS: We performed a retrospective, single-surgeon study of 17 consecutive adult patients (aged >18 years) who underwent open reduction internal fixation of an acute distal radius fracture with concurrent endoscopic carpal tunnel release at a level 1 trauma center between April 2017 and October 2020. Recovery from median nerve dysfunction was assessed from patient charts at routinely scheduled postoperative follow-up visits (at 2 weeks, 4 weeks, 6 weeks, and 12 weeks). RESULTS: The transverse carpal ligament could be visualized and released in all patients. All patients had a return of light touch sensibility with or without intermittent paresthesia by 12 weeks after surgery (the median time from surgery to recovery was 19 days [range, 12–82 days]). There were no patient reports or clinical examination evidence of palmar cutaneous branch, recurrent motor branch, or the third common digital nerve injury. Time to recovery was significantly different in the setting of high- versus low-energy trauma (26 days vs 18 days, respectively; P = .02). CONCLUSIONS: In this study, we demonstrated that concurrent endoscopic carpal tunnel release using the flexor carpi radialis approach for distal radius fracture fixation in the settings of high- and low-energy trauma is safe from major complications and effective at releasing the transverse carpal ligament. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.
format Online
Article
Text
id pubmed-9120784
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-91207842022-05-21 Surgical Technique for Concurrent Endoscopic Carpal Tunnel Release and Distal Radius Fracture Fixation Using the Flexor Carpi Radialis Approach: A Case Series Bhashyam, Abhiram R. Kao, Dennis S. J Hand Surg Glob Online Original Research PURPOSE: Multiple prior studies have assessed the results of open approaches for concurrent carpal tunnel release with distal radius fracture fixation; however, less is known regarding the feasibility of endoscopic techniques, especially in the setting of high-energy trauma. In this study, we assessed the feasibility and results of concurrent endoscopic carpal tunnel release and distal radius fracture fixation using the flexor carpi radialis approach after high- and low-energy trauma. METHODS: We performed a retrospective, single-surgeon study of 17 consecutive adult patients (aged >18 years) who underwent open reduction internal fixation of an acute distal radius fracture with concurrent endoscopic carpal tunnel release at a level 1 trauma center between April 2017 and October 2020. Recovery from median nerve dysfunction was assessed from patient charts at routinely scheduled postoperative follow-up visits (at 2 weeks, 4 weeks, 6 weeks, and 12 weeks). RESULTS: The transverse carpal ligament could be visualized and released in all patients. All patients had a return of light touch sensibility with or without intermittent paresthesia by 12 weeks after surgery (the median time from surgery to recovery was 19 days [range, 12–82 days]). There were no patient reports or clinical examination evidence of palmar cutaneous branch, recurrent motor branch, or the third common digital nerve injury. Time to recovery was significantly different in the setting of high- versus low-energy trauma (26 days vs 18 days, respectively; P = .02). CONCLUSIONS: In this study, we demonstrated that concurrent endoscopic carpal tunnel release using the flexor carpi radialis approach for distal radius fracture fixation in the settings of high- and low-energy trauma is safe from major complications and effective at releasing the transverse carpal ligament. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV. Elsevier 2022-01-13 /pmc/articles/PMC9120784/ /pubmed/35601523 http://dx.doi.org/10.1016/j.jhsg.2021.11.007 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Research
Bhashyam, Abhiram R.
Kao, Dennis S.
Surgical Technique for Concurrent Endoscopic Carpal Tunnel Release and Distal Radius Fracture Fixation Using the Flexor Carpi Radialis Approach: A Case Series
title Surgical Technique for Concurrent Endoscopic Carpal Tunnel Release and Distal Radius Fracture Fixation Using the Flexor Carpi Radialis Approach: A Case Series
title_full Surgical Technique for Concurrent Endoscopic Carpal Tunnel Release and Distal Radius Fracture Fixation Using the Flexor Carpi Radialis Approach: A Case Series
title_fullStr Surgical Technique for Concurrent Endoscopic Carpal Tunnel Release and Distal Radius Fracture Fixation Using the Flexor Carpi Radialis Approach: A Case Series
title_full_unstemmed Surgical Technique for Concurrent Endoscopic Carpal Tunnel Release and Distal Radius Fracture Fixation Using the Flexor Carpi Radialis Approach: A Case Series
title_short Surgical Technique for Concurrent Endoscopic Carpal Tunnel Release and Distal Radius Fracture Fixation Using the Flexor Carpi Radialis Approach: A Case Series
title_sort surgical technique for concurrent endoscopic carpal tunnel release and distal radius fracture fixation using the flexor carpi radialis approach: a case series
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9120784/
https://www.ncbi.nlm.nih.gov/pubmed/35601523
http://dx.doi.org/10.1016/j.jhsg.2021.11.007
work_keys_str_mv AT bhashyamabhiramr surgicaltechniqueforconcurrentendoscopiccarpaltunnelreleaseanddistalradiusfracturefixationusingtheflexorcarpiradialisapproachacaseseries
AT kaodenniss surgicaltechniqueforconcurrentendoscopiccarpaltunnelreleaseanddistalradiusfracturefixationusingtheflexorcarpiradialisapproachacaseseries