Cargando…

Comparison of Accu Chek Inform II point-of-care test blood glucose meter with Hexokinase Plasma method for a diabetes mellitus population during surgery under general anesthesia

PURPOSE: Blood glucose (BG) concentrations of patients with diabetes mellitus (DM) are monitored during surgery to prevent hypo- and hyperglycemia. Access to point-of-care test (POCT) glucose meters at an operating room will usually provide monitoring at shorter intervals and may improve glycemic co...

Descripción completa

Detalles Bibliográficos
Autores principales: Lascaris, B., Freling, H. G., Edens, M. A., Fokkert, M. J., Olthof, C. G., Slingerland, R. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9123023/
https://www.ncbi.nlm.nih.gov/pubmed/33496941
http://dx.doi.org/10.1007/s10877-021-00656-6
_version_ 1784711473731207168
author Lascaris, B.
Freling, H. G.
Edens, M. A.
Fokkert, M. J.
Olthof, C. G.
Slingerland, R. J.
author_facet Lascaris, B.
Freling, H. G.
Edens, M. A.
Fokkert, M. J.
Olthof, C. G.
Slingerland, R. J.
author_sort Lascaris, B.
collection PubMed
description PURPOSE: Blood glucose (BG) concentrations of patients with diabetes mellitus (DM) are monitored during surgery to prevent hypo- and hyperglycemia. Access to point-of-care test (POCT) glucose meters at an operating room will usually provide monitoring at shorter intervals and may improve glycemic control. However, these meters are not validated for patients under general anesthesia. METHODS: This cross-sectional study included 75 arterial BG measurements from 75 patients (71 with DM, mostly insulin dependent) who underwent elective non-cardiac surgery under general anesthesia. Arterial blood samples were taken at least 60 minutes after induction. One drop of blood was used for Accu Chek Inform II (ACI II) POCT BG meter and the residual blood was sent to the clinical laboratory for a Hexokinase Plasma reference method. A Bland–Altman plot was used to visualize the differences between both methods, and correlation was assessed using the intra-class correlation coefficient (ICC). RESULTS: The results showed an estimated mean difference of 0.8 mmol/L between ACI II and the reference method, with limits of agreement equal to -0.6 and 2.2 mmol/L. In general, the reference method produced higher values than ACI II. ICC was 0.955 (95% CI 0.634–0.986), P < 0.001, and concordance correlation coefficient (CCC) was 0.955 (95% CI 0.933–0.970). CONCLUSION: Arterial BG measurements during surgery in patients with DM under general anesthesia using POCT BG meter are in general lower than laboratory measurements, but the ICC and CCC show a clinically acceptable correlation. We conclude that POCT measurements conducted on arterial specimens using the ACI II provide sufficiently accurate results for glucose measurement during surgery under general anesthesia.
format Online
Article
Text
id pubmed-9123023
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-91230232022-05-22 Comparison of Accu Chek Inform II point-of-care test blood glucose meter with Hexokinase Plasma method for a diabetes mellitus population during surgery under general anesthesia Lascaris, B. Freling, H. G. Edens, M. A. Fokkert, M. J. Olthof, C. G. Slingerland, R. J. J Clin Monit Comput Original Research PURPOSE: Blood glucose (BG) concentrations of patients with diabetes mellitus (DM) are monitored during surgery to prevent hypo- and hyperglycemia. Access to point-of-care test (POCT) glucose meters at an operating room will usually provide monitoring at shorter intervals and may improve glycemic control. However, these meters are not validated for patients under general anesthesia. METHODS: This cross-sectional study included 75 arterial BG measurements from 75 patients (71 with DM, mostly insulin dependent) who underwent elective non-cardiac surgery under general anesthesia. Arterial blood samples were taken at least 60 minutes after induction. One drop of blood was used for Accu Chek Inform II (ACI II) POCT BG meter and the residual blood was sent to the clinical laboratory for a Hexokinase Plasma reference method. A Bland–Altman plot was used to visualize the differences between both methods, and correlation was assessed using the intra-class correlation coefficient (ICC). RESULTS: The results showed an estimated mean difference of 0.8 mmol/L between ACI II and the reference method, with limits of agreement equal to -0.6 and 2.2 mmol/L. In general, the reference method produced higher values than ACI II. ICC was 0.955 (95% CI 0.634–0.986), P < 0.001, and concordance correlation coefficient (CCC) was 0.955 (95% CI 0.933–0.970). CONCLUSION: Arterial BG measurements during surgery in patients with DM under general anesthesia using POCT BG meter are in general lower than laboratory measurements, but the ICC and CCC show a clinically acceptable correlation. We conclude that POCT measurements conducted on arterial specimens using the ACI II provide sufficiently accurate results for glucose measurement during surgery under general anesthesia. Springer Netherlands 2021-01-26 2022 /pmc/articles/PMC9123023/ /pubmed/33496941 http://dx.doi.org/10.1007/s10877-021-00656-6 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Research
Lascaris, B.
Freling, H. G.
Edens, M. A.
Fokkert, M. J.
Olthof, C. G.
Slingerland, R. J.
Comparison of Accu Chek Inform II point-of-care test blood glucose meter with Hexokinase Plasma method for a diabetes mellitus population during surgery under general anesthesia
title Comparison of Accu Chek Inform II point-of-care test blood glucose meter with Hexokinase Plasma method for a diabetes mellitus population during surgery under general anesthesia
title_full Comparison of Accu Chek Inform II point-of-care test blood glucose meter with Hexokinase Plasma method for a diabetes mellitus population during surgery under general anesthesia
title_fullStr Comparison of Accu Chek Inform II point-of-care test blood glucose meter with Hexokinase Plasma method for a diabetes mellitus population during surgery under general anesthesia
title_full_unstemmed Comparison of Accu Chek Inform II point-of-care test blood glucose meter with Hexokinase Plasma method for a diabetes mellitus population during surgery under general anesthesia
title_short Comparison of Accu Chek Inform II point-of-care test blood glucose meter with Hexokinase Plasma method for a diabetes mellitus population during surgery under general anesthesia
title_sort comparison of accu chek inform ii point-of-care test blood glucose meter with hexokinase plasma method for a diabetes mellitus population during surgery under general anesthesia
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9123023/
https://www.ncbi.nlm.nih.gov/pubmed/33496941
http://dx.doi.org/10.1007/s10877-021-00656-6
work_keys_str_mv AT lascarisb comparisonofaccuchekinformiipointofcaretestbloodglucosemeterwithhexokinaseplasmamethodforadiabetesmellituspopulationduringsurgeryundergeneralanesthesia
AT frelinghg comparisonofaccuchekinformiipointofcaretestbloodglucosemeterwithhexokinaseplasmamethodforadiabetesmellituspopulationduringsurgeryundergeneralanesthesia
AT edensma comparisonofaccuchekinformiipointofcaretestbloodglucosemeterwithhexokinaseplasmamethodforadiabetesmellituspopulationduringsurgeryundergeneralanesthesia
AT fokkertmj comparisonofaccuchekinformiipointofcaretestbloodglucosemeterwithhexokinaseplasmamethodforadiabetesmellituspopulationduringsurgeryundergeneralanesthesia
AT olthofcg comparisonofaccuchekinformiipointofcaretestbloodglucosemeterwithhexokinaseplasmamethodforadiabetesmellituspopulationduringsurgeryundergeneralanesthesia
AT slingerlandrj comparisonofaccuchekinformiipointofcaretestbloodglucosemeterwithhexokinaseplasmamethodforadiabetesmellituspopulationduringsurgeryundergeneralanesthesia