Cargando…

Ratiometric intracellular pH sensors based on nitrogen-doped graphene oxide quantum dots

Intracellular pH (pHi) is very essential for the function of cells and organisms. Thus, it is of great scientific and technical significance to develop nanosensors for probing pHi. In this work, nitrogen-doped graphene oxide quantum dots (N-GOQDs) with fluorescent efficiency of 54% are prepared. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Xiang, Gu, Yu, Zhang, Yun, Yu, Guo-Yin, Liao, Zhi-Peng, Wu, Hui-Fang, Shi, Chuan-Guo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9123205/
https://www.ncbi.nlm.nih.gov/pubmed/35607497
http://dx.doi.org/10.1016/j.heliyon.2022.e09411
_version_ 1784711503938584576
author Zhang, Xiang
Gu, Yu
Zhang, Yun
Yu, Guo-Yin
Liao, Zhi-Peng
Wu, Hui-Fang
Shi, Chuan-Guo
author_facet Zhang, Xiang
Gu, Yu
Zhang, Yun
Yu, Guo-Yin
Liao, Zhi-Peng
Wu, Hui-Fang
Shi, Chuan-Guo
author_sort Zhang, Xiang
collection PubMed
description Intracellular pH (pHi) is very essential for the function of cells and organisms. Thus, it is of great scientific and technical significance to develop nanosensors for probing pHi. In this work, nitrogen-doped graphene oxide quantum dots (N-GOQDs) with fluorescent efficiency of 54% are prepared. The fluorescent spectrum excited at 340 nm contains two remarkable bands at 430 and 520 nm. Interestingly, when pH value increases from 3.6 to 10.5, the blue band at 430 nm slightly changes, while the green band at 520 nm significantly quenches. The change of fluorescent intensities also can be reflected by the variation of fluorescent color. The dual-emissive N-GOQDs are developed as ratiometric fluorescent probes for pHi, which can avoid the influence of several deviations, such as probe concentration, optical path length, and detector efficiency. As a proof of concept, pHi of Hela cells is monitored successfully. This work demonstrates the construction of nano-biosensors based on N-GOQDs with bright fluorescence, high-stability, and good biocompatibility.
format Online
Article
Text
id pubmed-9123205
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-91232052022-05-22 Ratiometric intracellular pH sensors based on nitrogen-doped graphene oxide quantum dots Zhang, Xiang Gu, Yu Zhang, Yun Yu, Guo-Yin Liao, Zhi-Peng Wu, Hui-Fang Shi, Chuan-Guo Heliyon Research Article Intracellular pH (pHi) is very essential for the function of cells and organisms. Thus, it is of great scientific and technical significance to develop nanosensors for probing pHi. In this work, nitrogen-doped graphene oxide quantum dots (N-GOQDs) with fluorescent efficiency of 54% are prepared. The fluorescent spectrum excited at 340 nm contains two remarkable bands at 430 and 520 nm. Interestingly, when pH value increases from 3.6 to 10.5, the blue band at 430 nm slightly changes, while the green band at 520 nm significantly quenches. The change of fluorescent intensities also can be reflected by the variation of fluorescent color. The dual-emissive N-GOQDs are developed as ratiometric fluorescent probes for pHi, which can avoid the influence of several deviations, such as probe concentration, optical path length, and detector efficiency. As a proof of concept, pHi of Hela cells is monitored successfully. This work demonstrates the construction of nano-biosensors based on N-GOQDs with bright fluorescence, high-stability, and good biocompatibility. Elsevier 2022-05-13 /pmc/articles/PMC9123205/ /pubmed/35607497 http://dx.doi.org/10.1016/j.heliyon.2022.e09411 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Zhang, Xiang
Gu, Yu
Zhang, Yun
Yu, Guo-Yin
Liao, Zhi-Peng
Wu, Hui-Fang
Shi, Chuan-Guo
Ratiometric intracellular pH sensors based on nitrogen-doped graphene oxide quantum dots
title Ratiometric intracellular pH sensors based on nitrogen-doped graphene oxide quantum dots
title_full Ratiometric intracellular pH sensors based on nitrogen-doped graphene oxide quantum dots
title_fullStr Ratiometric intracellular pH sensors based on nitrogen-doped graphene oxide quantum dots
title_full_unstemmed Ratiometric intracellular pH sensors based on nitrogen-doped graphene oxide quantum dots
title_short Ratiometric intracellular pH sensors based on nitrogen-doped graphene oxide quantum dots
title_sort ratiometric intracellular ph sensors based on nitrogen-doped graphene oxide quantum dots
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9123205/
https://www.ncbi.nlm.nih.gov/pubmed/35607497
http://dx.doi.org/10.1016/j.heliyon.2022.e09411
work_keys_str_mv AT zhangxiang ratiometricintracellularphsensorsbasedonnitrogendopedgrapheneoxidequantumdots
AT guyu ratiometricintracellularphsensorsbasedonnitrogendopedgrapheneoxidequantumdots
AT zhangyun ratiometricintracellularphsensorsbasedonnitrogendopedgrapheneoxidequantumdots
AT yuguoyin ratiometricintracellularphsensorsbasedonnitrogendopedgrapheneoxidequantumdots
AT liaozhipeng ratiometricintracellularphsensorsbasedonnitrogendopedgrapheneoxidequantumdots
AT wuhuifang ratiometricintracellularphsensorsbasedonnitrogendopedgrapheneoxidequantumdots
AT shichuanguo ratiometricintracellularphsensorsbasedonnitrogendopedgrapheneoxidequantumdots