Cargando…

BoSL FAL pump: A small, low-cost, easily constructed, 3D-printed peristaltic pump for sampling of waters

Water sampling is an essential undertaking for water utilities and agencies to protect and enhance our natural resources. The high variability in water quality, however, often necessitates a spatially distributed sampling program which is impeded by high-cost and large sampling devices. This paper p...

Descripción completa

Detalles Bibliográficos
Autores principales: McCarthy, David T., Shi, Baiqian, Wang, Miao, Catsamas, Stephen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9123421/
https://www.ncbi.nlm.nih.gov/pubmed/35607656
http://dx.doi.org/10.1016/j.ohx.2021.e00214
_version_ 1784711551408668672
author McCarthy, David T.
Shi, Baiqian
Wang, Miao
Catsamas, Stephen
author_facet McCarthy, David T.
Shi, Baiqian
Wang, Miao
Catsamas, Stephen
author_sort McCarthy, David T.
collection PubMed
description Water sampling is an essential undertaking for water utilities and agencies to protect and enhance our natural resources. The high variability in water quality, however, often necessitates a spatially distributed sampling program which is impeded by high-cost and large sampling devices. This paper presents the BoSL FAL Pump - a low-cost, easily constructed, 3D-printed peristaltic pump which can be made from commonly available components and is sized to suit even the most space constrained installations. The pump is 38 mm in height and 28 mm in diameter, its components cost $19 AUD and the construction time is just 12 min (excluding 3D printing times). The pump is driven by a direct current motor which is commonly available, cheap and allows for flexibility in the energy supply (5–12 V). Optionally, the pump has a Hall effect sensor and magnet to detect rotation rates and pumping volumes to improve the accuracy of pumping rates/volumes. The pump can be easily controlled by commonly available microcontrollers, as demonstrated by this paper which implements the ATmega328P on the Arduino Uno R3. This paper validates the pump for long-term deployments at flow rates of up to 13 mL per minute in 0.14 mL volume increments at accuracy levels of greater than 99%. The pump itself is scalable, allowing for a wider range of pumping rates when, for example, large volume samples are required for pathogen and micropollutant detection.
format Online
Article
Text
id pubmed-9123421
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-91234212022-05-22 BoSL FAL pump: A small, low-cost, easily constructed, 3D-printed peristaltic pump for sampling of waters McCarthy, David T. Shi, Baiqian Wang, Miao Catsamas, Stephen HardwareX Article Water sampling is an essential undertaking for water utilities and agencies to protect and enhance our natural resources. The high variability in water quality, however, often necessitates a spatially distributed sampling program which is impeded by high-cost and large sampling devices. This paper presents the BoSL FAL Pump - a low-cost, easily constructed, 3D-printed peristaltic pump which can be made from commonly available components and is sized to suit even the most space constrained installations. The pump is 38 mm in height and 28 mm in diameter, its components cost $19 AUD and the construction time is just 12 min (excluding 3D printing times). The pump is driven by a direct current motor which is commonly available, cheap and allows for flexibility in the energy supply (5–12 V). Optionally, the pump has a Hall effect sensor and magnet to detect rotation rates and pumping volumes to improve the accuracy of pumping rates/volumes. The pump can be easily controlled by commonly available microcontrollers, as demonstrated by this paper which implements the ATmega328P on the Arduino Uno R3. This paper validates the pump for long-term deployments at flow rates of up to 13 mL per minute in 0.14 mL volume increments at accuracy levels of greater than 99%. The pump itself is scalable, allowing for a wider range of pumping rates when, for example, large volume samples are required for pathogen and micropollutant detection. Elsevier 2021-06-24 /pmc/articles/PMC9123421/ /pubmed/35607656 http://dx.doi.org/10.1016/j.ohx.2021.e00214 Text en © 2021 The Authors. Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
McCarthy, David T.
Shi, Baiqian
Wang, Miao
Catsamas, Stephen
BoSL FAL pump: A small, low-cost, easily constructed, 3D-printed peristaltic pump for sampling of waters
title BoSL FAL pump: A small, low-cost, easily constructed, 3D-printed peristaltic pump for sampling of waters
title_full BoSL FAL pump: A small, low-cost, easily constructed, 3D-printed peristaltic pump for sampling of waters
title_fullStr BoSL FAL pump: A small, low-cost, easily constructed, 3D-printed peristaltic pump for sampling of waters
title_full_unstemmed BoSL FAL pump: A small, low-cost, easily constructed, 3D-printed peristaltic pump for sampling of waters
title_short BoSL FAL pump: A small, low-cost, easily constructed, 3D-printed peristaltic pump for sampling of waters
title_sort bosl fal pump: a small, low-cost, easily constructed, 3d-printed peristaltic pump for sampling of waters
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9123421/
https://www.ncbi.nlm.nih.gov/pubmed/35607656
http://dx.doi.org/10.1016/j.ohx.2021.e00214
work_keys_str_mv AT mccarthydavidt boslfalpumpasmalllowcosteasilyconstructed3dprintedperistalticpumpforsamplingofwaters
AT shibaiqian boslfalpumpasmalllowcosteasilyconstructed3dprintedperistalticpumpforsamplingofwaters
AT wangmiao boslfalpumpasmalllowcosteasilyconstructed3dprintedperistalticpumpforsamplingofwaters
AT catsamasstephen boslfalpumpasmalllowcosteasilyconstructed3dprintedperistalticpumpforsamplingofwaters