Cargando…

Saccadic Latency Measures on Oculomotor Tracking and King Devick Testing Performance Measures in Pediatric Concussion Patients

BACKGROUND: King-Devick (KD) testing has been a reliable clinical tool used to identify changes in rapid eye movements between fixation points (saccades) after concussion. Other clinical tools such as oculomotor tracking (OMT) devices have been used to assess the extent of visual dysfunction in conc...

Descripción completa

Detalles Bibliográficos
Autores principales: Sarva, Saikaashyap, Thirunagari, Prem Kumar, Rieiro, Hector, Bell, Matthew, Streeter, Leslie, Minor, Jon, Balaji, Arvind, Dusenberry, Brett, Mortazavi, Mo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9125652/
http://dx.doi.org/10.1177/2325967121S00526
_version_ 1784711983473360896
author Sarva, Saikaashyap
Thirunagari, Prem Kumar
Rieiro, Hector
Bell, Matthew
Streeter, Leslie
Minor, Jon
Balaji, Arvind
Dusenberry, Brett
Mortazavi, Mo
author_facet Sarva, Saikaashyap
Thirunagari, Prem Kumar
Rieiro, Hector
Bell, Matthew
Streeter, Leslie
Minor, Jon
Balaji, Arvind
Dusenberry, Brett
Mortazavi, Mo
author_sort Sarva, Saikaashyap
collection PubMed
description BACKGROUND: King-Devick (KD) testing has been a reliable clinical tool used to identify changes in rapid eye movements between fixation points (saccades) after concussion. Other clinical tools such as oculomotor tracking (OMT) devices have been used to assess the extent of visual dysfunction in concussion patients to aid diagnosis, subtyping, and symptom management. PURPOSE: To compare trends in OMT saccadic motion analysis data to KD times/performance in concussed patients. METHODS: Retrospective study of 66 pediatric patients (ages 12 to 21) with concussion. KD testing was conducted using standard 3 card protocol with a series of numbers which the patient reads aloud in a specific pattern as fast and accurately as possible without head movement. The length of time to complete each card was noted and the three KD times were averaged, resulting in one mean KD value for each patient. Patients were categorized into either a “Fast” (average KD time from 0 - 20 seconds), n=56, or “Slow” group (average KD time above 20 seconds), n=10. Each patient underwent testing with an OMT device during the same visit (250 Hz video-eye tracker), which measured vertical and horizontal saccadic latencies. Statistical analysis using a paired two sample t-test assuming equal variances compared the OMT data between the slow and fast groups. Exclusion criteria included history of visual disorders, learning disorders, seizure disorder, or intracranial hemorrhage. RESULTS: The slow KD group had an average vertical saccadic latency of 248.88 ms and a horizontal saccadic latency of 214.66 ms (Table 1). The fast KD group had an average vertical saccadic latency of 217 ms and a horizontal saccadic latency of 196.64 ms. A t-test of vertical latency showed a statistically significant difference between slow and fast groups (p value = 0.002). A T-test of horizontal latency resulted in a p value = 0.069, which may support a statistically significant difference with a larger sample size. CONCLUSION: A potential relationship between patients with slower KD test times and slower horizontal/ vertical saccadic latencies on OMT saccadic analysis may be present. However, these trends will need more testing under larger sample sizes in order to make definitive conclusions.
format Online
Article
Text
id pubmed-9125652
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-91256522022-05-24 Saccadic Latency Measures on Oculomotor Tracking and King Devick Testing Performance Measures in Pediatric Concussion Patients Sarva, Saikaashyap Thirunagari, Prem Kumar Rieiro, Hector Bell, Matthew Streeter, Leslie Minor, Jon Balaji, Arvind Dusenberry, Brett Mortazavi, Mo Orthop J Sports Med Article BACKGROUND: King-Devick (KD) testing has been a reliable clinical tool used to identify changes in rapid eye movements between fixation points (saccades) after concussion. Other clinical tools such as oculomotor tracking (OMT) devices have been used to assess the extent of visual dysfunction in concussion patients to aid diagnosis, subtyping, and symptom management. PURPOSE: To compare trends in OMT saccadic motion analysis data to KD times/performance in concussed patients. METHODS: Retrospective study of 66 pediatric patients (ages 12 to 21) with concussion. KD testing was conducted using standard 3 card protocol with a series of numbers which the patient reads aloud in a specific pattern as fast and accurately as possible without head movement. The length of time to complete each card was noted and the three KD times were averaged, resulting in one mean KD value for each patient. Patients were categorized into either a “Fast” (average KD time from 0 - 20 seconds), n=56, or “Slow” group (average KD time above 20 seconds), n=10. Each patient underwent testing with an OMT device during the same visit (250 Hz video-eye tracker), which measured vertical and horizontal saccadic latencies. Statistical analysis using a paired two sample t-test assuming equal variances compared the OMT data between the slow and fast groups. Exclusion criteria included history of visual disorders, learning disorders, seizure disorder, or intracranial hemorrhage. RESULTS: The slow KD group had an average vertical saccadic latency of 248.88 ms and a horizontal saccadic latency of 214.66 ms (Table 1). The fast KD group had an average vertical saccadic latency of 217 ms and a horizontal saccadic latency of 196.64 ms. A t-test of vertical latency showed a statistically significant difference between slow and fast groups (p value = 0.002). A T-test of horizontal latency resulted in a p value = 0.069, which may support a statistically significant difference with a larger sample size. CONCLUSION: A potential relationship between patients with slower KD test times and slower horizontal/ vertical saccadic latencies on OMT saccadic analysis may be present. However, these trends will need more testing under larger sample sizes in order to make definitive conclusions. SAGE Publications 2022-05-13 /pmc/articles/PMC9125652/ http://dx.doi.org/10.1177/2325967121S00526 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc-nd/4.0/This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For article reuse guidelines, please visit SAGE’s website at http://www.sagepub.com/journals-permissions.
spellingShingle Article
Sarva, Saikaashyap
Thirunagari, Prem Kumar
Rieiro, Hector
Bell, Matthew
Streeter, Leslie
Minor, Jon
Balaji, Arvind
Dusenberry, Brett
Mortazavi, Mo
Saccadic Latency Measures on Oculomotor Tracking and King Devick Testing Performance Measures in Pediatric Concussion Patients
title Saccadic Latency Measures on Oculomotor Tracking and King Devick Testing Performance Measures in Pediatric Concussion Patients
title_full Saccadic Latency Measures on Oculomotor Tracking and King Devick Testing Performance Measures in Pediatric Concussion Patients
title_fullStr Saccadic Latency Measures on Oculomotor Tracking and King Devick Testing Performance Measures in Pediatric Concussion Patients
title_full_unstemmed Saccadic Latency Measures on Oculomotor Tracking and King Devick Testing Performance Measures in Pediatric Concussion Patients
title_short Saccadic Latency Measures on Oculomotor Tracking and King Devick Testing Performance Measures in Pediatric Concussion Patients
title_sort saccadic latency measures on oculomotor tracking and king devick testing performance measures in pediatric concussion patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9125652/
http://dx.doi.org/10.1177/2325967121S00526
work_keys_str_mv AT sarvasaikaashyap saccadiclatencymeasuresonoculomotortrackingandkingdevicktestingperformancemeasuresinpediatricconcussionpatients
AT thirunagaripremkumar saccadiclatencymeasuresonoculomotortrackingandkingdevicktestingperformancemeasuresinpediatricconcussionpatients
AT rieirohector saccadiclatencymeasuresonoculomotortrackingandkingdevicktestingperformancemeasuresinpediatricconcussionpatients
AT bellmatthew saccadiclatencymeasuresonoculomotortrackingandkingdevicktestingperformancemeasuresinpediatricconcussionpatients
AT streeterleslie saccadiclatencymeasuresonoculomotortrackingandkingdevicktestingperformancemeasuresinpediatricconcussionpatients
AT minorjon saccadiclatencymeasuresonoculomotortrackingandkingdevicktestingperformancemeasuresinpediatricconcussionpatients
AT balajiarvind saccadiclatencymeasuresonoculomotortrackingandkingdevicktestingperformancemeasuresinpediatricconcussionpatients
AT dusenberrybrett saccadiclatencymeasuresonoculomotortrackingandkingdevicktestingperformancemeasuresinpediatricconcussionpatients
AT mortazavimo saccadiclatencymeasuresonoculomotortrackingandkingdevicktestingperformancemeasuresinpediatricconcussionpatients