Cargando…

Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study

BACKGROUND: Correct choice of the implant design and the occlusal scheme is important for the success of implant supported restorations. So, the aim of the current study was to find out the difference in the stresses induced by the one piece dental implants designed to be used in the All-on-4® conce...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohamed, Ahmed Mostafa Abdelfattah, Askar, Mohamed Gamal, El Homossany, Mahmoud El-Moutassim Bellah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9125928/
https://www.ncbi.nlm.nih.gov/pubmed/35599323
http://dx.doi.org/10.1186/s12903-022-02228-9
_version_ 1784712033425424384
author Mohamed, Ahmed Mostafa Abdelfattah
Askar, Mohamed Gamal
El Homossany, Mahmoud El-Moutassim Bellah
author_facet Mohamed, Ahmed Mostafa Abdelfattah
Askar, Mohamed Gamal
El Homossany, Mahmoud El-Moutassim Bellah
author_sort Mohamed, Ahmed Mostafa Abdelfattah
collection PubMed
description BACKGROUND: Correct choice of the implant design and the occlusal scheme is important for the success of implant supported restorations. So, the aim of the current study was to find out the difference in the stresses induced by the one piece dental implants designed to be used in the All-on-4® concept and the conventional two piece ones under simulated lateral occlusal schemes using nonlinear finite element analysis. METHODS: Two finite element models of the maxilla, implants, and prostheses were designed according to the All-on-4® concept. In the model TP, two piece dental implants were placed while in the model OP one piece dental implants were used. Two loading scenarios were applied to each model; the first one simulated a group function occlusal scheme while the second scenario simulated a canine guided one. RESULTS: The highest stress value was recorded in the model TP with the group function occlusion and the lowest stress value was in the model OP with the canine guidance occlusion. CONCLUSION: The one-piece dental implants can be concluded to induce less stress compared to the two piece dental implants when used in the All-on-4® implant supported prosthesis in the different lateral occlusal schemes. Canine guided occlusion can be concluded to cause lower stress values in comparison to the group function occlusal scheme.
format Online
Article
Text
id pubmed-9125928
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-91259282022-05-24 Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study Mohamed, Ahmed Mostafa Abdelfattah Askar, Mohamed Gamal El Homossany, Mahmoud El-Moutassim Bellah BMC Oral Health Research Article BACKGROUND: Correct choice of the implant design and the occlusal scheme is important for the success of implant supported restorations. So, the aim of the current study was to find out the difference in the stresses induced by the one piece dental implants designed to be used in the All-on-4® concept and the conventional two piece ones under simulated lateral occlusal schemes using nonlinear finite element analysis. METHODS: Two finite element models of the maxilla, implants, and prostheses were designed according to the All-on-4® concept. In the model TP, two piece dental implants were placed while in the model OP one piece dental implants were used. Two loading scenarios were applied to each model; the first one simulated a group function occlusal scheme while the second scenario simulated a canine guided one. RESULTS: The highest stress value was recorded in the model TP with the group function occlusion and the lowest stress value was in the model OP with the canine guidance occlusion. CONCLUSION: The one-piece dental implants can be concluded to induce less stress compared to the two piece dental implants when used in the All-on-4® implant supported prosthesis in the different lateral occlusal schemes. Canine guided occlusion can be concluded to cause lower stress values in comparison to the group function occlusal scheme. BioMed Central 2022-05-22 /pmc/articles/PMC9125928/ /pubmed/35599323 http://dx.doi.org/10.1186/s12903-022-02228-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Mohamed, Ahmed Mostafa Abdelfattah
Askar, Mohamed Gamal
El Homossany, Mahmoud El-Moutassim Bellah
Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study
title Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study
title_full Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study
title_fullStr Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study
title_full_unstemmed Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study
title_short Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study
title_sort stresses induced by one piece and two piece dental implants in all-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9125928/
https://www.ncbi.nlm.nih.gov/pubmed/35599323
http://dx.doi.org/10.1186/s12903-022-02228-9
work_keys_str_mv AT mohamedahmedmostafaabdelfattah stressesinducedbyonepieceandtwopiecedentalimplantsinallon4implantsupportedprosthesisundersimulatedlateralocclusalloadingnonlinearfiniteelementanalysisstudy
AT askarmohamedgamal stressesinducedbyonepieceandtwopiecedentalimplantsinallon4implantsupportedprosthesisundersimulatedlateralocclusalloadingnonlinearfiniteelementanalysisstudy
AT elhomossanymahmoudelmoutassimbellah stressesinducedbyonepieceandtwopiecedentalimplantsinallon4implantsupportedprosthesisundersimulatedlateralocclusalloadingnonlinearfiniteelementanalysisstudy