Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study
BACKGROUND: Correct choice of the implant design and the occlusal scheme is important for the success of implant supported restorations. So, the aim of the current study was to find out the difference in the stresses induced by the one piece dental implants designed to be used in the All-on-4® conce...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9125928/ https://www.ncbi.nlm.nih.gov/pubmed/35599323 http://dx.doi.org/10.1186/s12903-022-02228-9 |
_version_ | 1784712033425424384 |
---|---|
author | Mohamed, Ahmed Mostafa Abdelfattah Askar, Mohamed Gamal El Homossany, Mahmoud El-Moutassim Bellah |
author_facet | Mohamed, Ahmed Mostafa Abdelfattah Askar, Mohamed Gamal El Homossany, Mahmoud El-Moutassim Bellah |
author_sort | Mohamed, Ahmed Mostafa Abdelfattah |
collection | PubMed |
description | BACKGROUND: Correct choice of the implant design and the occlusal scheme is important for the success of implant supported restorations. So, the aim of the current study was to find out the difference in the stresses induced by the one piece dental implants designed to be used in the All-on-4® concept and the conventional two piece ones under simulated lateral occlusal schemes using nonlinear finite element analysis. METHODS: Two finite element models of the maxilla, implants, and prostheses were designed according to the All-on-4® concept. In the model TP, two piece dental implants were placed while in the model OP one piece dental implants were used. Two loading scenarios were applied to each model; the first one simulated a group function occlusal scheme while the second scenario simulated a canine guided one. RESULTS: The highest stress value was recorded in the model TP with the group function occlusion and the lowest stress value was in the model OP with the canine guidance occlusion. CONCLUSION: The one-piece dental implants can be concluded to induce less stress compared to the two piece dental implants when used in the All-on-4® implant supported prosthesis in the different lateral occlusal schemes. Canine guided occlusion can be concluded to cause lower stress values in comparison to the group function occlusal scheme. |
format | Online Article Text |
id | pubmed-9125928 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-91259282022-05-24 Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study Mohamed, Ahmed Mostafa Abdelfattah Askar, Mohamed Gamal El Homossany, Mahmoud El-Moutassim Bellah BMC Oral Health Research Article BACKGROUND: Correct choice of the implant design and the occlusal scheme is important for the success of implant supported restorations. So, the aim of the current study was to find out the difference in the stresses induced by the one piece dental implants designed to be used in the All-on-4® concept and the conventional two piece ones under simulated lateral occlusal schemes using nonlinear finite element analysis. METHODS: Two finite element models of the maxilla, implants, and prostheses were designed according to the All-on-4® concept. In the model TP, two piece dental implants were placed while in the model OP one piece dental implants were used. Two loading scenarios were applied to each model; the first one simulated a group function occlusal scheme while the second scenario simulated a canine guided one. RESULTS: The highest stress value was recorded in the model TP with the group function occlusion and the lowest stress value was in the model OP with the canine guidance occlusion. CONCLUSION: The one-piece dental implants can be concluded to induce less stress compared to the two piece dental implants when used in the All-on-4® implant supported prosthesis in the different lateral occlusal schemes. Canine guided occlusion can be concluded to cause lower stress values in comparison to the group function occlusal scheme. BioMed Central 2022-05-22 /pmc/articles/PMC9125928/ /pubmed/35599323 http://dx.doi.org/10.1186/s12903-022-02228-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Mohamed, Ahmed Mostafa Abdelfattah Askar, Mohamed Gamal El Homossany, Mahmoud El-Moutassim Bellah Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study |
title | Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study |
title_full | Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study |
title_fullStr | Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study |
title_full_unstemmed | Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study |
title_short | Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study |
title_sort | stresses induced by one piece and two piece dental implants in all-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9125928/ https://www.ncbi.nlm.nih.gov/pubmed/35599323 http://dx.doi.org/10.1186/s12903-022-02228-9 |
work_keys_str_mv | AT mohamedahmedmostafaabdelfattah stressesinducedbyonepieceandtwopiecedentalimplantsinallon4implantsupportedprosthesisundersimulatedlateralocclusalloadingnonlinearfiniteelementanalysisstudy AT askarmohamedgamal stressesinducedbyonepieceandtwopiecedentalimplantsinallon4implantsupportedprosthesisundersimulatedlateralocclusalloadingnonlinearfiniteelementanalysisstudy AT elhomossanymahmoudelmoutassimbellah stressesinducedbyonepieceandtwopiecedentalimplantsinallon4implantsupportedprosthesisundersimulatedlateralocclusalloadingnonlinearfiniteelementanalysisstudy |