Cargando…

Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries

OBJECTIVE: The main objective is to explore the diagnostic value of magnetic resonance imaging (MRI) scan, multislice spiral computed tomography (MSCT) three-dimensional reconstruction combined with plain film X-ray in spiral injuries. METHODS: By means of retrospective study, the data of 100 patien...

Descripción completa

Detalles Bibliográficos
Autores principales: Xin, Dajiang, Lei, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9126705/
https://www.ncbi.nlm.nih.gov/pubmed/35655726
http://dx.doi.org/10.1155/2022/8998231
_version_ 1784712186237550592
author Xin, Dajiang
Lei, Lei
author_facet Xin, Dajiang
Lei, Lei
author_sort Xin, Dajiang
collection PubMed
description OBJECTIVE: The main objective is to explore the diagnostic value of magnetic resonance imaging (MRI) scan, multislice spiral computed tomography (MSCT) three-dimensional reconstruction combined with plain film X-ray in spiral injuries. METHODS: By means of retrospective study, the data of 100 patients with spiral injury treated in our hospital from January 2020 to December 2021 were retrospectively analyzed, and all patients received MRI scan, MSCT three-dimensional reconstruction, and plain film X-ray examination, and by taking the operation results as the reference, the diagnostic results of different diagnostic modalities were analyzed, and the accordance rates (diagnostic result/surgical result × 100%) of the three diagnostic modalities and their combination were calculated, respectively. RESULTS: Among the 100 patients, 52 cases (52%) had a fracture at the anterior column of the spine, 28 cases (28%) had a fracture at the middle column of the spine, and 20 cases (20%) had a fracture at the posterior column of spine; 24 cases (24%) had simple flexion compression fracture, 60 cases (60%) had burst fracture, 6 cases (6%) had seat belt fracture, and 10 cases (10%) had fracture dislocation. The accordance rate of combined diagnosis for fracture site was 100%, and that for fracture type was 98.0%; MRI could visualize bone marrow injuries, ligamentous injuries, soft tissue injuries, and nerve root injuries that could not be visualized on X-ray plain films, and 3D reconstruction with MSCT could clearly demonstrate the 3D relationship of spinal fracture displacement, fracture line orientation, and spinal injury. CONCLUSION: Plain film X-ray is the basic method for diagnosing spinal injuries, while MRI and MSCT have their unique advantages in this regard, and patients with a negative result of X-ray plain film can be examined by MRI and MSCT to observe the spinal injury comprehensively.
format Online
Article
Text
id pubmed-9126705
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-91267052022-06-01 Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries Xin, Dajiang Lei, Lei Contrast Media Mol Imaging Research Article OBJECTIVE: The main objective is to explore the diagnostic value of magnetic resonance imaging (MRI) scan, multislice spiral computed tomography (MSCT) three-dimensional reconstruction combined with plain film X-ray in spiral injuries. METHODS: By means of retrospective study, the data of 100 patients with spiral injury treated in our hospital from January 2020 to December 2021 were retrospectively analyzed, and all patients received MRI scan, MSCT three-dimensional reconstruction, and plain film X-ray examination, and by taking the operation results as the reference, the diagnostic results of different diagnostic modalities were analyzed, and the accordance rates (diagnostic result/surgical result × 100%) of the three diagnostic modalities and their combination were calculated, respectively. RESULTS: Among the 100 patients, 52 cases (52%) had a fracture at the anterior column of the spine, 28 cases (28%) had a fracture at the middle column of the spine, and 20 cases (20%) had a fracture at the posterior column of spine; 24 cases (24%) had simple flexion compression fracture, 60 cases (60%) had burst fracture, 6 cases (6%) had seat belt fracture, and 10 cases (10%) had fracture dislocation. The accordance rate of combined diagnosis for fracture site was 100%, and that for fracture type was 98.0%; MRI could visualize bone marrow injuries, ligamentous injuries, soft tissue injuries, and nerve root injuries that could not be visualized on X-ray plain films, and 3D reconstruction with MSCT could clearly demonstrate the 3D relationship of spinal fracture displacement, fracture line orientation, and spinal injury. CONCLUSION: Plain film X-ray is the basic method for diagnosing spinal injuries, while MRI and MSCT have their unique advantages in this regard, and patients with a negative result of X-ray plain film can be examined by MRI and MSCT to observe the spinal injury comprehensively. Hindawi 2022-05-16 /pmc/articles/PMC9126705/ /pubmed/35655726 http://dx.doi.org/10.1155/2022/8998231 Text en Copyright © 2022 Dajiang Xin and Lei Lei. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Xin, Dajiang
Lei, Lei
Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries
title Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries
title_full Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries
title_fullStr Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries
title_full_unstemmed Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries
title_short Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries
title_sort diagnostic value of magnetic resonance imaging scan, multislice spiral computed tomography three-dimensional reconstruction combined with plain film x-ray in spinal injuries
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9126705/
https://www.ncbi.nlm.nih.gov/pubmed/35655726
http://dx.doi.org/10.1155/2022/8998231
work_keys_str_mv AT xindajiang diagnosticvalueofmagneticresonanceimagingscanmultislicespiralcomputedtomographythreedimensionalreconstructioncombinedwithplainfilmxrayinspinalinjuries
AT leilei diagnosticvalueofmagneticresonanceimagingscanmultislicespiralcomputedtomographythreedimensionalreconstructioncombinedwithplainfilmxrayinspinalinjuries