Cargando…
Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries
OBJECTIVE: The main objective is to explore the diagnostic value of magnetic resonance imaging (MRI) scan, multislice spiral computed tomography (MSCT) three-dimensional reconstruction combined with plain film X-ray in spiral injuries. METHODS: By means of retrospective study, the data of 100 patien...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9126705/ https://www.ncbi.nlm.nih.gov/pubmed/35655726 http://dx.doi.org/10.1155/2022/8998231 |
_version_ | 1784712186237550592 |
---|---|
author | Xin, Dajiang Lei, Lei |
author_facet | Xin, Dajiang Lei, Lei |
author_sort | Xin, Dajiang |
collection | PubMed |
description | OBJECTIVE: The main objective is to explore the diagnostic value of magnetic resonance imaging (MRI) scan, multislice spiral computed tomography (MSCT) three-dimensional reconstruction combined with plain film X-ray in spiral injuries. METHODS: By means of retrospective study, the data of 100 patients with spiral injury treated in our hospital from January 2020 to December 2021 were retrospectively analyzed, and all patients received MRI scan, MSCT three-dimensional reconstruction, and plain film X-ray examination, and by taking the operation results as the reference, the diagnostic results of different diagnostic modalities were analyzed, and the accordance rates (diagnostic result/surgical result × 100%) of the three diagnostic modalities and their combination were calculated, respectively. RESULTS: Among the 100 patients, 52 cases (52%) had a fracture at the anterior column of the spine, 28 cases (28%) had a fracture at the middle column of the spine, and 20 cases (20%) had a fracture at the posterior column of spine; 24 cases (24%) had simple flexion compression fracture, 60 cases (60%) had burst fracture, 6 cases (6%) had seat belt fracture, and 10 cases (10%) had fracture dislocation. The accordance rate of combined diagnosis for fracture site was 100%, and that for fracture type was 98.0%; MRI could visualize bone marrow injuries, ligamentous injuries, soft tissue injuries, and nerve root injuries that could not be visualized on X-ray plain films, and 3D reconstruction with MSCT could clearly demonstrate the 3D relationship of spinal fracture displacement, fracture line orientation, and spinal injury. CONCLUSION: Plain film X-ray is the basic method for diagnosing spinal injuries, while MRI and MSCT have their unique advantages in this regard, and patients with a negative result of X-ray plain film can be examined by MRI and MSCT to observe the spinal injury comprehensively. |
format | Online Article Text |
id | pubmed-9126705 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-91267052022-06-01 Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries Xin, Dajiang Lei, Lei Contrast Media Mol Imaging Research Article OBJECTIVE: The main objective is to explore the diagnostic value of magnetic resonance imaging (MRI) scan, multislice spiral computed tomography (MSCT) three-dimensional reconstruction combined with plain film X-ray in spiral injuries. METHODS: By means of retrospective study, the data of 100 patients with spiral injury treated in our hospital from January 2020 to December 2021 were retrospectively analyzed, and all patients received MRI scan, MSCT three-dimensional reconstruction, and plain film X-ray examination, and by taking the operation results as the reference, the diagnostic results of different diagnostic modalities were analyzed, and the accordance rates (diagnostic result/surgical result × 100%) of the three diagnostic modalities and their combination were calculated, respectively. RESULTS: Among the 100 patients, 52 cases (52%) had a fracture at the anterior column of the spine, 28 cases (28%) had a fracture at the middle column of the spine, and 20 cases (20%) had a fracture at the posterior column of spine; 24 cases (24%) had simple flexion compression fracture, 60 cases (60%) had burst fracture, 6 cases (6%) had seat belt fracture, and 10 cases (10%) had fracture dislocation. The accordance rate of combined diagnosis for fracture site was 100%, and that for fracture type was 98.0%; MRI could visualize bone marrow injuries, ligamentous injuries, soft tissue injuries, and nerve root injuries that could not be visualized on X-ray plain films, and 3D reconstruction with MSCT could clearly demonstrate the 3D relationship of spinal fracture displacement, fracture line orientation, and spinal injury. CONCLUSION: Plain film X-ray is the basic method for diagnosing spinal injuries, while MRI and MSCT have their unique advantages in this regard, and patients with a negative result of X-ray plain film can be examined by MRI and MSCT to observe the spinal injury comprehensively. Hindawi 2022-05-16 /pmc/articles/PMC9126705/ /pubmed/35655726 http://dx.doi.org/10.1155/2022/8998231 Text en Copyright © 2022 Dajiang Xin and Lei Lei. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Xin, Dajiang Lei, Lei Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries |
title | Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries |
title_full | Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries |
title_fullStr | Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries |
title_full_unstemmed | Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries |
title_short | Diagnostic Value of Magnetic Resonance Imaging Scan, Multislice Spiral Computed Tomography Three-Dimensional Reconstruction Combined with Plain Film X-Ray in Spinal Injuries |
title_sort | diagnostic value of magnetic resonance imaging scan, multislice spiral computed tomography three-dimensional reconstruction combined with plain film x-ray in spinal injuries |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9126705/ https://www.ncbi.nlm.nih.gov/pubmed/35655726 http://dx.doi.org/10.1155/2022/8998231 |
work_keys_str_mv | AT xindajiang diagnosticvalueofmagneticresonanceimagingscanmultislicespiralcomputedtomographythreedimensionalreconstructioncombinedwithplainfilmxrayinspinalinjuries AT leilei diagnosticvalueofmagneticresonanceimagingscanmultislicespiralcomputedtomographythreedimensionalreconstructioncombinedwithplainfilmxrayinspinalinjuries |