Cargando…

The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay

Androstenedione (ASD) is a biomarker used in the diagnostic workup of hyperandrogenism, congenital adrenal hyperplasia, premature adrenarche, and polycystic ovary syndrome (PCOS). The Elecsys ASD competitive electrochemiluminescence immunoassay (Roche Diagnostics, Indianapolis, IN) is a new assay re...

Descripción completa

Detalles Bibliográficos
Autores principales: Wei, Ruhan, Bowers, Kathleen, Kroner, Grace M., Payto, Drew, Colón-Franco, Jessica M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9127399/
https://www.ncbi.nlm.nih.gov/pubmed/35620064
http://dx.doi.org/10.1016/j.plabm.2022.e00279
_version_ 1784712344705695744
author Wei, Ruhan
Bowers, Kathleen
Kroner, Grace M.
Payto, Drew
Colón-Franco, Jessica M.
author_facet Wei, Ruhan
Bowers, Kathleen
Kroner, Grace M.
Payto, Drew
Colón-Franco, Jessica M.
author_sort Wei, Ruhan
collection PubMed
description Androstenedione (ASD) is a biomarker used in the diagnostic workup of hyperandrogenism, congenital adrenal hyperplasia, premature adrenarche, and polycystic ovary syndrome (PCOS). The Elecsys ASD competitive electrochemiluminescence immunoassay (Roche Diagnostics, Indianapolis, IN) is a new assay recently available in the US. OBJECTIVE: This study evaluated the analytical and clinical performance of the Elecsys ASD assay. DESIGN & METHODS: We evaluated the linearity/analytical measuring range (AMR), precision, and accuracy of the Elecsys ASD assay on the cobas e601 analyzer. ASD was measured in serum/plasma in the Elecsys ASD, Immulite (Siemens Medical Solutions USA, Inc. Malvern, PA), and LC-MS/MS assays. Reference intervals (RI) were evaluated across genders, menopausal status, and in children. Statistical analysis was performed using EP evaluator and R program. RESULTS: The Elecsys ASD assay had a linear response across the AMR. The intra- and inter-assay coefficients of variation at various concentrations were ≤4.5%. The Elecsys ASD assay had a mean difference of −0.04 ng/mL (−1.7%) with the LC-MS/MS assay, whereas the Immulite assay had a mean difference of 1.17 ng/mL (66%) and −1.22 ng/mL (−38%) compared to the LC-MS/MS and Elecsys ASD assays, respectively. The Roche recommended RIs for healthy men (0.280–1.52 ng/mL) and postmenopausal women (0.187–1.07 ng/mL) were successfully verified. The RIs for children were adopted from published data. For pre-menopausal women, a RI of <1.60 ng/mL was established. The ASD concentrations in women with and without PCOS overlapped. CONCLUSIONS: The Elecsys ASD assay has superior comparability to the LC-MS/MS assay than the Immulite assay.
format Online
Article
Text
id pubmed-9127399
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-91273992022-05-25 The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay Wei, Ruhan Bowers, Kathleen Kroner, Grace M. Payto, Drew Colón-Franco, Jessica M. Pract Lab Med Original Research Article Androstenedione (ASD) is a biomarker used in the diagnostic workup of hyperandrogenism, congenital adrenal hyperplasia, premature adrenarche, and polycystic ovary syndrome (PCOS). The Elecsys ASD competitive electrochemiluminescence immunoassay (Roche Diagnostics, Indianapolis, IN) is a new assay recently available in the US. OBJECTIVE: This study evaluated the analytical and clinical performance of the Elecsys ASD assay. DESIGN & METHODS: We evaluated the linearity/analytical measuring range (AMR), precision, and accuracy of the Elecsys ASD assay on the cobas e601 analyzer. ASD was measured in serum/plasma in the Elecsys ASD, Immulite (Siemens Medical Solutions USA, Inc. Malvern, PA), and LC-MS/MS assays. Reference intervals (RI) were evaluated across genders, menopausal status, and in children. Statistical analysis was performed using EP evaluator and R program. RESULTS: The Elecsys ASD assay had a linear response across the AMR. The intra- and inter-assay coefficients of variation at various concentrations were ≤4.5%. The Elecsys ASD assay had a mean difference of −0.04 ng/mL (−1.7%) with the LC-MS/MS assay, whereas the Immulite assay had a mean difference of 1.17 ng/mL (66%) and −1.22 ng/mL (−38%) compared to the LC-MS/MS and Elecsys ASD assays, respectively. The Roche recommended RIs for healthy men (0.280–1.52 ng/mL) and postmenopausal women (0.187–1.07 ng/mL) were successfully verified. The RIs for children were adopted from published data. For pre-menopausal women, a RI of <1.60 ng/mL was established. The ASD concentrations in women with and without PCOS overlapped. CONCLUSIONS: The Elecsys ASD assay has superior comparability to the LC-MS/MS assay than the Immulite assay. Elsevier 2022-05-10 /pmc/articles/PMC9127399/ /pubmed/35620064 http://dx.doi.org/10.1016/j.plabm.2022.e00279 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
Wei, Ruhan
Bowers, Kathleen
Kroner, Grace M.
Payto, Drew
Colón-Franco, Jessica M.
The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay
title The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay
title_full The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay
title_fullStr The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay
title_full_unstemmed The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay
title_short The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay
title_sort androstenedione roche elecsys immunoassay has superior comparability to the lc-ms/ms assay than the siemens immulite immunoassay
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9127399/
https://www.ncbi.nlm.nih.gov/pubmed/35620064
http://dx.doi.org/10.1016/j.plabm.2022.e00279
work_keys_str_mv AT weiruhan theandrostenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay
AT bowerskathleen theandrostenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay
AT kronergracem theandrostenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay
AT paytodrew theandrostenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay
AT colonfrancojessicam theandrostenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay
AT weiruhan androstenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay
AT bowerskathleen androstenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay
AT kronergracem androstenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay
AT paytodrew androstenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay
AT colonfrancojessicam androstenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay