Cargando…
The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay
Androstenedione (ASD) is a biomarker used in the diagnostic workup of hyperandrogenism, congenital adrenal hyperplasia, premature adrenarche, and polycystic ovary syndrome (PCOS). The Elecsys ASD competitive electrochemiluminescence immunoassay (Roche Diagnostics, Indianapolis, IN) is a new assay re...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9127399/ https://www.ncbi.nlm.nih.gov/pubmed/35620064 http://dx.doi.org/10.1016/j.plabm.2022.e00279 |
_version_ | 1784712344705695744 |
---|---|
author | Wei, Ruhan Bowers, Kathleen Kroner, Grace M. Payto, Drew Colón-Franco, Jessica M. |
author_facet | Wei, Ruhan Bowers, Kathleen Kroner, Grace M. Payto, Drew Colón-Franco, Jessica M. |
author_sort | Wei, Ruhan |
collection | PubMed |
description | Androstenedione (ASD) is a biomarker used in the diagnostic workup of hyperandrogenism, congenital adrenal hyperplasia, premature adrenarche, and polycystic ovary syndrome (PCOS). The Elecsys ASD competitive electrochemiluminescence immunoassay (Roche Diagnostics, Indianapolis, IN) is a new assay recently available in the US. OBJECTIVE: This study evaluated the analytical and clinical performance of the Elecsys ASD assay. DESIGN & METHODS: We evaluated the linearity/analytical measuring range (AMR), precision, and accuracy of the Elecsys ASD assay on the cobas e601 analyzer. ASD was measured in serum/plasma in the Elecsys ASD, Immulite (Siemens Medical Solutions USA, Inc. Malvern, PA), and LC-MS/MS assays. Reference intervals (RI) were evaluated across genders, menopausal status, and in children. Statistical analysis was performed using EP evaluator and R program. RESULTS: The Elecsys ASD assay had a linear response across the AMR. The intra- and inter-assay coefficients of variation at various concentrations were ≤4.5%. The Elecsys ASD assay had a mean difference of −0.04 ng/mL (−1.7%) with the LC-MS/MS assay, whereas the Immulite assay had a mean difference of 1.17 ng/mL (66%) and −1.22 ng/mL (−38%) compared to the LC-MS/MS and Elecsys ASD assays, respectively. The Roche recommended RIs for healthy men (0.280–1.52 ng/mL) and postmenopausal women (0.187–1.07 ng/mL) were successfully verified. The RIs for children were adopted from published data. For pre-menopausal women, a RI of <1.60 ng/mL was established. The ASD concentrations in women with and without PCOS overlapped. CONCLUSIONS: The Elecsys ASD assay has superior comparability to the LC-MS/MS assay than the Immulite assay. |
format | Online Article Text |
id | pubmed-9127399 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-91273992022-05-25 The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay Wei, Ruhan Bowers, Kathleen Kroner, Grace M. Payto, Drew Colón-Franco, Jessica M. Pract Lab Med Original Research Article Androstenedione (ASD) is a biomarker used in the diagnostic workup of hyperandrogenism, congenital adrenal hyperplasia, premature adrenarche, and polycystic ovary syndrome (PCOS). The Elecsys ASD competitive electrochemiluminescence immunoassay (Roche Diagnostics, Indianapolis, IN) is a new assay recently available in the US. OBJECTIVE: This study evaluated the analytical and clinical performance of the Elecsys ASD assay. DESIGN & METHODS: We evaluated the linearity/analytical measuring range (AMR), precision, and accuracy of the Elecsys ASD assay on the cobas e601 analyzer. ASD was measured in serum/plasma in the Elecsys ASD, Immulite (Siemens Medical Solutions USA, Inc. Malvern, PA), and LC-MS/MS assays. Reference intervals (RI) were evaluated across genders, menopausal status, and in children. Statistical analysis was performed using EP evaluator and R program. RESULTS: The Elecsys ASD assay had a linear response across the AMR. The intra- and inter-assay coefficients of variation at various concentrations were ≤4.5%. The Elecsys ASD assay had a mean difference of −0.04 ng/mL (−1.7%) with the LC-MS/MS assay, whereas the Immulite assay had a mean difference of 1.17 ng/mL (66%) and −1.22 ng/mL (−38%) compared to the LC-MS/MS and Elecsys ASD assays, respectively. The Roche recommended RIs for healthy men (0.280–1.52 ng/mL) and postmenopausal women (0.187–1.07 ng/mL) were successfully verified. The RIs for children were adopted from published data. For pre-menopausal women, a RI of <1.60 ng/mL was established. The ASD concentrations in women with and without PCOS overlapped. CONCLUSIONS: The Elecsys ASD assay has superior comparability to the LC-MS/MS assay than the Immulite assay. Elsevier 2022-05-10 /pmc/articles/PMC9127399/ /pubmed/35620064 http://dx.doi.org/10.1016/j.plabm.2022.e00279 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article Wei, Ruhan Bowers, Kathleen Kroner, Grace M. Payto, Drew Colón-Franco, Jessica M. The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay |
title | The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay |
title_full | The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay |
title_fullStr | The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay |
title_full_unstemmed | The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay |
title_short | The Androstenedione Roche Elecsys immunoassay has superior comparability to the LC-MS/MS assay than the Siemens Immulite immunoassay |
title_sort | androstenedione roche elecsys immunoassay has superior comparability to the lc-ms/ms assay than the siemens immulite immunoassay |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9127399/ https://www.ncbi.nlm.nih.gov/pubmed/35620064 http://dx.doi.org/10.1016/j.plabm.2022.e00279 |
work_keys_str_mv | AT weiruhan theandrostenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay AT bowerskathleen theandrostenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay AT kronergracem theandrostenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay AT paytodrew theandrostenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay AT colonfrancojessicam theandrostenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay AT weiruhan androstenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay AT bowerskathleen androstenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay AT kronergracem androstenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay AT paytodrew androstenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay AT colonfrancojessicam androstenedionerocheelecsysimmunoassayhassuperiorcomparabilitytothelcmsmsassaythanthesiemensimmuliteimmunoassay |