Acute airway obstruction by a mucus plug in a patient with a 12-year history of inserting a double cannula tracheostomy tube: A case report
Acute airway obstruction long after tracheostomy has rarely been reported. An 81-year-old Japanese woman with a tracheostomy tube for 12 years developed a 2-day history of coughing-up sputum with difficulty, foreign body sensation, and mild dyspnea. Dyspnea worsened immediately after computed tomogr...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9127856/ https://www.ncbi.nlm.nih.gov/pubmed/35619750 http://dx.doi.org/10.1177/2050313X221100874 |
Sumario: | Acute airway obstruction long after tracheostomy has rarely been reported. An 81-year-old Japanese woman with a tracheostomy tube for 12 years developed a 2-day history of coughing-up sputum with difficulty, foreign body sensation, and mild dyspnea. Dyspnea worsened immediately after computed tomography, showing soft tissue opacity between the tip of the tracheostomy tube and the bronchi. A movable mass in the trachea, identified as mucus by pathological examination, was removed using bronchoscopy. Acute airway obstruction by a mucus plug potentially occurred with a long history of insertion of a tracheostomy tube. Emergency imaging studies and bronchoscopy were useful for management. |
---|