Acute airway obstruction by a mucus plug in a patient with a 12-year history of inserting a double cannula tracheostomy tube: A case report

Acute airway obstruction long after tracheostomy has rarely been reported. An 81-year-old Japanese woman with a tracheostomy tube for 12 years developed a 2-day history of coughing-up sputum with difficulty, foreign body sensation, and mild dyspnea. Dyspnea worsened immediately after computed tomogr...

Descripción completa

Detalles Bibliográficos
Autores principales: Miyata, Jun, Dateoka, Kaname, Yoshioka, Tetsuya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9127856/
https://www.ncbi.nlm.nih.gov/pubmed/35619750
http://dx.doi.org/10.1177/2050313X221100874
Descripción
Sumario:Acute airway obstruction long after tracheostomy has rarely been reported. An 81-year-old Japanese woman with a tracheostomy tube for 12 years developed a 2-day history of coughing-up sputum with difficulty, foreign body sensation, and mild dyspnea. Dyspnea worsened immediately after computed tomography, showing soft tissue opacity between the tip of the tracheostomy tube and the bronchi. A movable mass in the trachea, identified as mucus by pathological examination, was removed using bronchoscopy. Acute airway obstruction by a mucus plug potentially occurred with a long history of insertion of a tracheostomy tube. Emergency imaging studies and bronchoscopy were useful for management.